My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3101 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3101 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 1:06:37 PM
Creation date
2/28/2025 11:04:52 AM
Metadata
Fields
Template:
Building Plans
Street #
3101
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
22758
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CORNER OF <br />HOME — <br />GARAGE SIDE <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />cy, <br />zo <br />+++ <br />15/32" CDX <br />m <br />PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" <br />WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />8d RING SHANK NAILS @ 6" O.C. EDGES & <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />0,280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH <br />21NCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND <br />OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ + <br />+ + + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />6'-0° <br />+ <br />6'-0'1 <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + + + <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8' <br />5000s 1.811.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-118" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x lumber <br />DOUBLE JOIST CONSTW.1� <br />(Not required if both load <br />Filler bl1/8" gap <br />FILL CELL <br />cn <br />w <br />EE <br />> STD:90° <br />CONT. #5 HOOK <br />BAR <br />STD, 900 HOOK BOND BEAM <br />CONT. #5 <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min.) Small gap 2" min. <br />2" max <br />4 max. <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 4" max <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />BCI 5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2.8d <br />5-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when Indicated or <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP TOP sides b 6". Hangers with side nailing. <br />@ Y - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth guts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 15001b. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 pif max along load bearing wall. <br />Load bearing wall must stack <br />*Non stacking walls over squash=20 blocks and <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />'� lateral load. nail each side <br />10 -0 at bearing. <br />TANK -LESS W/H <br />H C G <br />0 0 0 <br />5'-011 a - <br />0 <br />STUB -OUT FOR 1'-0" o LO <br />GAS METER 0 1 0 <br />c CI U <br />O F <br />(V o <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-81, <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X i 2" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block / \ <br />(2x4 minimum) !�jj <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES <br />DO NOT cut, notch <br />or drill flanges <br />BLOCKING PANEL, INTERIOR <br />Boise Joist Blocking Vertical load transfer =1900 pif max. along bearing wall <br />Use 3" (10d) nails at 6" o.c. Required on interior walls : for vertical load transfer <br />Load bearing walls 7 when load bearing for lateral support when joists <br />/ meet over wall, or wall stacks directly over wall or <br />SIMPSC <br />w/ (22) <br />NAILS T <br />5/8" Q <br />THRU <br />BOLT <br />SIMPSC <br />w/(22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT—UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />for each lapped joist. <br />blocking panel *Non -stacking walls <br />Od nails SECTION" INT. BRG. WALL require additional consideration.- <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />IRA <br />Alk <br />ROUND HOLE MAY 611 611 DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y" <br />1 Any 16" joist 112 1 1'-0" 1 I'A ".1 1'-2" 1 1,_2.1 V-3" I V-9" 12'-4- 1 2"-11'" 1 3-7" 1 4'-2"" 1 4-9" 1 5'-4" 1 <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT, DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />A <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) -111=1 I I- TTi <br />Nail with 10-10d nails. — <br />Install tight to top flange. a <br />SLEEVE THRU STEM <br />°. <br />SEE PLAN FOR---'°• • • <br />FOUNDATION INFO <br />STEM FOUNDATION <br />J, r GRADE nrrKlc ecn nl nnr <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top/0.6 <br />required if hanger <br />flange is laterally supported by joist hangedoesn't meet <br />height <br />requirements <br />X Joist <br />o depth <br />I —JOISTS BUCKETS <br />N.T.S. <br />r-v� �nr1oE 1r r v%l <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />/:��% <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />JOA <br />LOCATION OF <br />SECOND H10A <br />SIMPSON (WHEN <br />w/ (18) 10dREQUIRED) <br />NAILS <br />UPLIFT =1 <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE PLUMBING LINE <br />PENETRATION <br />q e 4 <br />z • a .. <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4 G d d <br />°' <br />4 <br />I I=1 I I=1 =1 ° . • = I=1 <br />d i- <br />T V d <br />�i c• �II 1 <br />P- <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />f <br />r;. <br />l x <br />,f <br />t � <br />3 <br />4 <br />�N���� <br />"� <br />UA <br />0. <br />A� <br />,� F �0 <br />•a. <br />"//Zffa O F g SIO <br />f�fi'if jl'id! 1lFE4t�\ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />a004£ <br />8 ' <br />�8 <br />co pip <br />• <br />� � � <br />5 M N ti N-� <br />N it Tk <br />J J <br />LL LL <br />M ���� <br />�,oW o <br />a a; iL: <br />0 <br />0.29 <br />as z0❑ <br />Z <br />6 <br />m <br />W C N <br />2 Ec'0, <br />m ° o <br />W <br />CLLL CN <br />�❑ a 0 <br /> < <br />co <br />� <br />� o <br />_ t o <br />o <br />0 Z <br />d N <br />�/ I z <br />� � o <br />lL <br />(11MN <br />=n Y <br />W �- <br />n <br />V a <br />OQ) rl, <br />V) O <br />to <br />o <br />c� m <br />0 88 <br />u ... <br />I <br />0 <br />x. <br />93 <br />¢ 8 <br />ti <br />w <br />low M <br />M <br />¢ <br />zo <br />Z <br />U__ <br />c E <br />OO <br />E Q <br />= <br />Z. <br />20 <br />oa <br />m to <br />~C1 <br />o E <br />o< <br />as <br />=o <br />N r0 <br />L <br />woo <br />¢o <br />az <br />�w <br />sue.. <br />N�fu <br />- <br />�o <br />iiig <br />O <br />oLL <br />oneca <br />w <br />oa <br /><w <br />Z <br />o a <br />���rrr <br />w LL <br />v w <br />>� <br />C:) <br />to <br />t0 <br />z ¢ <br />a <br />1.) <br />0 <br />2 CV <br />_ <br />Lo d: <br />J <br />L <br />ai <br />/I <br />W <br />m <br />0 <br />r <br />'— <br />Ln <br />T-- <br />> <br />O <br />CD <br />0 <br />0 <br />70 <br />J T_ <br />L0 <br />0 <br />,— CV <br />r <br />T <br />1 �— o <br />LOT <br />N <br />m <br />51M \ <br />� �— N CAI <br />0 <br />z <br />z <br />E (Dr <br />E .a <br />m <br />EL <br />6 <br />U Q 0 <br />JOB <br />NO : 20-1125 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />t 3 r: <br />
The URL can be used to link to this page
Your browser does not support the video tag.