My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3120 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3120 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 1:16:34 PM
Creation date
2/28/2025 11:05:03 AM
Metadata
Fields
Template:
Building Plans
Street #
3120
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
22746
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
aci <br />0 <br />0 <br />L0 <br />O <br />0 <br />it <br />ATTIC VENTILATION CALCULATIONS <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />19.000000 <br />2.000000 <br />Floor <br />2276 <br />2185 <br />312 <br />1092 <br />78 <br />546 <br />561.0 <br />285.0 <br />276.0 <br />(Zone 1) <br />"NOTE" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN - ELEV-B1 <br />SCALE: %4'=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN, OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA /UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />tikl.iEdiaifC.Jp/vx^/ <br />14bty�'i�85 <br />nwtv <br />w, r y � � ''• <br />w�l <br />Cr <br />Z <br />r 0 <br />•r v <br />C� Q <br />r F <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />MM <br />W <br />F <br />AAR <br />W$ <br />7 <br />� `° <br />cloD <br />N r_ W <br />a <br />yr <br />N CV ) <br />J J <br />LL LL <br />® <br />N <br />�M[T-D <br />g LL N <br />J Xk W W <br />LL_j a a <br />0M <br />Q <br />13 a <br />> m LL: <br />a <br />W Lu <br />°- d Cr Y <br />� p 0 <br />Z <br />m.�o <br />XmO <br />Q: <br />all'ru <br />C N <br />o r- <br />CO <br />LLLL <br />0 <br />N Q c'M Z <br />�oN <br />U <br />° <br />,Z <br />Z <br />0 <br />❑❑❑❑ <br />W <br />0 0 <br />z <br />z o <br />Q <br />_! M <br />N <br />LJ <br />N <br />M <br />l6 <br />z <br />o <br />� <br />� <br />CJ <br />Cn Y <br />F <br />WFL <br />o a <br />O <br />c/) <br />to <br />w h <br />� o <br />U <br />w <br />E <br />o <br />_ <br />U o <br />Q rn rn <br />Sm <br />O <br />M <br />w <br />¢ <br />z <br />LJL <br />E <br />z � <br />Wo <br />z <br />a N <br />2 <br />E <br />z® <br />❑a <br />Z <br />9U <br />— <br />O <br />XO14 <br />U <br />a <br />Q Z <br />u o <br />p <br />o K <br />W Z <br />N <br />o <br />�� <br />>.- <br />n3 <br />C:0Y <br />¢o <br />z <br />U <br />mo� <br />of <br />z <br />J <br />o m <br />tl <br />Q W <br />�z <br />cn <br />o� <br />z <br />go <br />W <br />d <br />29 <br />d <br />nw <br />J <br />� <br />ali <br />�w <br />< <br />r=3 <br />o� <br />O <br />CoaF <br />cY <br />z< <br />' � <br />oo3 <br />�N <br />0 <br />= <br />` <br />J <br />ai <br />rn <br />m <br />L <br />ns <br />O <br />00 <br />./ <br />0 <br />> <br />i••� <br />O <br />A <br />C <br />I— <br />W <br />T <br />y <br />Ill- <br />OC <br />•� <br />J O <br />r <br />2 00 <br />N M <br />r <br />ui <br />w <br />M <br />o <br />E <br />m <br />c <br />v <br />iri r <br />Z <br />Z <br />E O <br />E <br />t— <br />f <br />m <br />0_ <br />o <br />U � <br />c <br />JOB <br />NO: <br />20-0562 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />5 <br />