Laserfiche WebLink
ROOF DIAPHRAGM NAILING SCHEDULE <br />� RIDGE LINE <br />w 15/32" CDX <br />m PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 21NCH NAIL LENGTH <br />NOTE: 1* FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED.. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + <br />+ + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist Backer Block <br />Series <br />Thickness Filler Block Thickness <br />3/4° or 7/8" Two 3/4" wood panels or 2 x _ <br />5000s 1.8/1.7 wood panels <br />1-1l8" or two 1/2" <br />6000s 1.8/1.7 wood panels 2 x _ + 5/8" or 3/4" wood: panel <br />1-1/8" or two 1 /2" <br />6500s 1.$/1.7 wood panels 2 x _ + 5/8" or 3/4" wood panel <br />1-1!$" or two 1!2" <br />602.0 wood panels 2 x _ + 5/8" or 3/4" wood panel <br />90 2.0 2 x _lumber Double 2 x _lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap --� <br />FILL CELL—\ r— STD. 900 HOOK �-- BOND BEAM <br />TYP. <br />�GIRDERTRUSS <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap --� <br />FILL CELL—\ r— STD. 900 HOOK �-- BOND BEAM <br />TYP. <br />�GIRDERTRUSS <br />SIMPSON MGT <br />w/ (22)10d <br />w <br />NAILS <br />� BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION TJI TO BE CUT TO ALLOW <br />.FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @INT. BRG.. WALL <br />N.T.S. <br />1/8" min.) Small gap 2° min. <br />2" max. � 4' max. <br />4 <br />Clinch nails <br />when <br />possible IR I <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Black solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />VerL. tical load transfer =1900 plf max along load bearing wall. <br />Load. bearing wall must stack <br />*Non -stacking walls over squash=20 blocks and <br />require additional wall or beam below.* <br />consideration. Check. <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />' ,r lateral load. nail each side <br />10 -0 at bearing. <br />TANK -LESS W!H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" <br />STUB -OUT FOR O 1'-O" o o ,-�� <br />GAS METER d. � <br />O <br />tV _ <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-$" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />BLOCKING PANEL, INTERIOR <br />Boise Joist Blocking Vertical load transfer =1900 plf max, along bearing wall <br />Use 3" (10d) nails at 6" o.c. Required on interior walls: -for vertical load transfer <br />Load bearing walls when load bearing -for lateral support when joists <br />�j meet over wall, or wall stacks directly over wall or <br />.beam below Load bearing wall must stack over <br />blocking and wall or beam below.* --� <br />Provide adequate bearing <br />for each lapped joist. <br />Squash block 1od Halls SECTION @INT. BRG. WALL <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />B�� A 1�" ROUND HOLE MAY -� 6„ 6�� DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN %" <br />8 <br />1'-0" <br />1 `-1 "' 1'-2" 1'-2" <br />1'-3" 1,-3" <br />1, 7" <br />1'-11,' <br />2•-4" <br />2 �9" <br />3`-2.. <br />3,-7,. <br />Any 16" joist <br />12 <br />1'-0" <br />1'-'I" <br />1'-2" <br />1'-2'" <br />1'-3" <br />1,-+9" <br />2'-4" <br />2'-11" <br />3'-7" <br />4'-2"' <br />4'-9°' <br />S'-4" <br />Span (it) <br />16 <br />1'-0" <br />1'-2" <br />1'-2" <br />1'-7" <br />2'~5" <br />3'-2" <br />3'-10" <br />4'-9" <br />5'-7" <br />6'-4" <br />7°-2" <br />20 <br />1'-0°' <br />1'-1" <br />1'-2" <br />1'-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11" <br />6'-11" <br />T-11" <br />8`-11"' <br />.�_ <br />24 <br />1'-0" <br />1'-1 " <br />1,_2" <br />1'-3" <br />2'-5" <br />3'-7" <br />4 =9" <br />5'-1 t?" <br />T-2" <br />1 p'_9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES: HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS, <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE, <br />7.1Y" ROUND KNOCKOUTS IN THE WEB MAYBE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAYBE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAYBE SET WITH THE 1�" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAYBE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series Depth End Intermediate <br />BCI5000s � <br />9-1/2" <br />11-7/8" <br />2-$d <br />2-8d <br />2-$d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/$" <br />2-8d <br />2-$d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-$d <br />16" <br />2-8d <br />6-$d <br />BCI60s0 <br />11-7/$" <br />2-8d <br />3-$d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />2 X B.U.0 <br />SIMPSON MGT <br />w/ (22)10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />VIIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />Joist <br />When joists meet over wall, provide <br />13i4"minimum bearing for each. I -Joist -can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) -1 I I —I I t-`III—IIT-Tfl"`� <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM <br />e <br />SEE PLAN FOR °• ° . • .; . <br />FOUNDATION INFO ° 4' ° 6 <br />STEM FOUNDATION <br />Filler black. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2"gap <br />Backer Block <br />"Top Mount" "'Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />i/4"-2" gap at top of bottom 1l4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />p depth <br />F, <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />/ <br />i—REINF. SEE PLAN <br />AlC CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @MID SPAN <br />NOTE:. <br />.UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° s° (WHEN <br />w/ (18)10d x 1 1/2 ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0"— <br />CENETERED @PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @PIPE PLUMBING LINE <br />PENETRATION co <br />31, <br />e , <br />SEE FND. PLN. <br />SIZE &REINF. <br />PIPE PERPENDICULAR TO FND. <br />IL <br />IL <br />CIL <br />- <br />LD <br />O <br />_W CIO <br />J <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @PIPE <br />PENETRATION PLUMBING LINE <br />' d e°. as G <br />4 <br />SEE FND. PLN. <br />SIZE &REINF. <br />+ /++ + + + k\ ...... 4- -4- -4- F + <br />0 <br />1 <br />3 F <br />4 �f <br />i <br />A.; <br />t <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residentiat 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bear11- ing <br />Engineer's signature and seal. <br />M <br />W vS <br />� <br />O p 0 <br />M N N (o <br />� J � <br />�00 LL LL <br />yM� SO) <br />� b <br />� LL a � <br />� y M <br />a ;m�3 <br />c <br />a rw � Y <br />,. , <br />a y <br />m m O Q <br />W 'ca 01­"° <br />W 2 E _� O <br />� 4 = <br />H <br />