My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3160 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3160 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 1:22:09 PM
Creation date
2/28/2025 11:05:07 AM
Metadata
Fields
Template:
Building Plans
Street #
3160
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
22503
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />912 copper to 20 amp ckts <br />00 AMP AM 200 <br />910-2 copper to WH <br />#10.3 copper to Dryer <br />MAIN <br />O <br />or 410 SER Alu <br />200 amp <br />Y10 <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WP WEATHERPROOF DUPLEX OUTLET <br />GFI GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />FqiiF- <br />HALF-SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />4'3 THREE-WAY SWITCH <br />?4, FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />#PC LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e� TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />O <br />`' EXHAUST FAN/LIGHT COMBINATION <br />tr <br />�D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CO CARBON MONOXIDE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />Q TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />N TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />IM ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />DISC. b <br />WP <br />PAT I O <br />IN <br />I ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />'�WqN E R'S <br />G U I T E <br />��CSD <br />ll 1-7 �• �..� I <br />I <br />I <br />00 <br />LO <br />I <br />CA <br />I <br />I <br />1 <br />I <br />I <br />a-- I <br />/ I <br />l <br />I <br />U.C. SWITCH <br />FOR DISPOSAk <br />I <br />1 <br />I <br />I � <br />I <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ i <br />LIGHT PRE-WIl <br />FA M I LY R.Po'I / =E <br />/ <br />/ <br />/ <br />/ <br />/ <br />REF. <br />NIM 11,:R1111110 <br />FOR I <br />ALARM <br />SYSTEM <br />I <br />V0 C . <br />I <br />I <br />-------------� <br />N=3 <br />/ ROUGH -IN FOR / <br />OPT. CLG. FAN/ / <br />LIGHT PRE -WIRE <br />/ // �\ ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />i , BEDROOM 2 <br />BEDROOM 3 <br />t� M01 <br />WP <br />FOYER _ n GFI <br />GFI @ 44" <br />7W.H. <br />A.F.F. <br />f - - - - - - - - - - - - <br />I <br />O <br />I <br />II 11 <br />11J^(I <br />I1 I <br />I <br />I <br />1 I <br />I <br />I.- v .J / QU) <br />I <br />GFI @ <br />/ <br />I- a ll <br />44" <br />/ <br />U <br />GARAGE <br />A.F.F. <br />w rr <br />w <br />Q- <br />I DOOR <br />C7 <br />I GFI <br />� <br />I <br />I <br />/ <br />J <br />Q <br />0 <br />2 CAR <br />GARAGE <br />I <br />ha/ <br />I <br />I <br />I <br />I <br />VERIFY LOCATION <br />I <br />I IRRIGATION <br />ELECTRICAL PANEL <br />gFI @ 44" A.F.F. <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />ENTRY <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4'=1'-0" <br />i <br />l,. <br />1') <br />1 <br />rr <br />0 <br />N <br />0 <br />N <br />CIO <br />N <br />0 <br />To the best of the Engineer's knowledge. information and belief. <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building <br />Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />Q <br />c ECo <br />o00 <br />N CO <br />s* <br />01 <br />Cl) <br />n J LL <br />0 <br />N <br />M r N <br />m -O <br />3 _j <br />OD <br />J itW <br />rL J n a <br />M <br />a <br />Oj 04 <br />M 5 <br />W LL u Q <br />aaW0 <br />Z <br />�CLL52 <br />� to 0 <br />K Y <br />0 ° 9 <br />=�a <br />mm0o <br />W <br />Fo o� <br />o <br />W <br />LL <br />EmZo <br />rn _� � o <br />W p a g <br />tY <br />04 <br />z <br />° d <br />I" O I� ❑ <br />W <br />M � <br />M <br />Z tV o <br />_ <br />Z <br />J M <br />fZ N <br />N <br />M <br />z <br />0 o <br />� <br />LL <br />U% Y <br />(aw� <br />o0 <br />.o ¢ <br />v ' <br />N <br />° <br />fC5 <br />r <br />� m <br />wigw <br />�- E2 E <br />0 3 <br />I <br />zlr... <br />= <br />C) o <br />° <br />Q rn rn <br />40— <br />co <br />Cl) <br />2 $ <br />S <br />Z <br />Z <br />U_ <br />c6 E <br />O <br />E <br />wo <br />�� <br />�Z <br />>N <br />?® <br />u <br />�_O <br />&¢ <br />wof <br />0° <br />S� <br />aE <br />N <br />.o <br />aZ <br />ra <br />� <br />W� <br />�Z <br />Z <br />Z <br />J <br />�m <br /><w <br />�z <br />Wa) <br />Fm <br />of <br />o <br />�� <br />a <br />w m <br />W <br />o <br />z <br />�F <br />co <br />co <br />W <br />0 °d <br />dx <br />Q <br />d- <br />z <br />o 3 <br />�M <br />0 <br />= <br />` <br />>M <br />J <br />ui <br />rn <br />m <br />L <br />t° <br />0 <br />^` <br />W <br />T <br />00 <br />^ <br />' <br />W m <br />= <br />� <br />f <br />O <br />C37 <br />00 <br />V) <br />1� <br />r <br />N <br />T <br />hi <br />w <br />CY) <br />o <br />z <br />Eca Q <br />a <br />E • • <br />U J <br />a «� <br />Q 0 <br />c <br />J <br />JOB <br />NO: <br />20-0565 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />