ATTIC VENTILATION CALCULATIONS - Al <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />f o <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />29.00000 <br />1.000000 <br />Floor <br />2373 <br />2278 <br />325 <br />1139 <br />81 <br />570 <br />0 <br />573.0 <br />435.0 <br />138.0 <br />(Zone 1) <br />*'NOTE* <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />SCALE: %4'=l'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />0 PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN, OF NET FREE AREA / SQ. FT. <br />0 <br />C <br />rc , <br />AV <br />%J <br />o' <br />l <br />M r <br />z N O <br />0 0 <br />z g <br />e Q <br />� N <br />V) <br />(9 0 <br />V1 Y LL, O <br />U., <br />a <br />V) <br />�� N <br />(� o <br />U m; <br />w <br />8 <br />`= <br />!! O I N <br />ID <br />`_ di <br />t <br />� <br />N N <br />b <br />o <br />Z o o v w Z <br />m M m O <br />Lu a <br />W =�IPZ <br />� <br />cia'a.-�A <br />o <br />o�,aw <br />111�4 ,� �a o <br />eoLL <br />v e <br />C` f' <br />'Q a <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />r— <br />o <br />w <br />co <br />M <br />i¢ <br />o <br />Z <br />¢ <br />LJL <br />O E <br />E ® <br />zo <br />oo <br />F'z <br />ym <br />aN <br />z® <br />oa <br />ca <br />XO <br />O¢ <br />OO <br />O� <br />�O re <br />N r <br />az <br />o <br />z <br />a <br />rc z <br />LZ <br />OY <br />O <br />m0 <br />OE <br />Z <br />Cn <br />iZ <br />oa <br />1 <br />go <br />a <br />mw <br />_ <br />U <br /><& <br />oz <br />23 <br />G <br />C <br />L Y <br />II� <br />a o <br />A <br />OU <br />C O <br />O <br />.N <br />L <br />^L1 <br />W <br />rro <br />M <br />> <br />O <br />U 0 <br />O <br />m cc <br />C <br />a-� <br />r- <br />V <br />T <br />•T� J o <br />LID <br />T <br />.L. C0 N N <br />CO <br />r <br />W <br />r M N <br />coN <br />o <br />z <br />M <br />z <br />E cn a <br />is <br />_ <br />E <br />U Q cc 0 <br />� <br />JOB <br />NO: 19-5909 <br />SCALE : AS NOTED <br />SHEET NO. <br />5.0 <br />