My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3225 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3225 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 2:23:34 PM
Creation date
2/28/2025 11:05:54 AM
Metadata
Fields
Template:
Building Plans
Street #
3225
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
22100
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TYP @ 2 STORY <br />J <br />S6 <br />H.B.t <br />43'-0" <br />38'-0" <br />(3) 2X4 #2 SPF W/ (3)16d 1 <br />TOENAILS @ BASE 8 <br />COND. COND. <br />J <br />S6 <br />I I I I I IG I <br />I I I I I S3 ;� <br />I I I IUP 116R1 I I <br />I I 13 11I 17 I <br />TYP @ 2 STORY <br />o <br />4 5 8 <br />°° <br />FLOOR G.T. <br />9 <br />io <br />42" SLOPING 0 10 <br />FAMILY ROOM <br />HALF WALL 11 - -- <br />00 <br />8'-8" FLAT CLG. <br />W/ (3) #2dSPF Ba -_ 12 - -- <br />FLEX <br />= <br />A <br />O <br /><V <br />CARPET <br />TOENAILS @ <br />BASE <br />8'-8" FLAT CLG. <br />8'-8' AT <br />CARPET <br />AO <br />S3 ao v <br />u7U0 <br />M <br />00 C <br />- - <br />4'-0" 0 <br />N <br />x <br />5-SH 60 <br />H4 <br />r <br />12"DEEP <br />2068 B.F. <br />HDR AT T-4" <br />ENT R <br />N <br />'- <br />16'-4$" <br />I <br />T-8" 3'-6" <br />3 <br />6 <br />FLAT CIL <br />J= <br />C7 C7 0 <br />I <br />FOYER ----,-- I <br />O <br />� <br />- <br />o <br />S6 <br />TYP 2 STORY <br />@ <br />OI OI OI "' <br />8'-8" FLAT CLG. 3068 <br />(2) #5'S <br />O O O <br />TILE I <br />(3) 2X4 #2 SPF W/ <br />------- <br />o <br />(3) 16d TOENAILS @ <br />BASE <br />W.H. <br />i3) 2X4 #2 SPF W/ <br />CSC3 4'0"n -0" <br />o <br />CD <br />iNv <br />16d TOENAILS <br />ON <br />@)BASE <br />- - - - - -- --- <br />C�7 <br />2'-6" BUILDER TO PROVIDE <br />I D I I <br />S3 <br />00 <br />Ocn <br />APPLIANCE PROTECTION <br />I I I <br />DINING ROOM <br />WHEN REQUIRED PER FBC <br />I I <br />PATIO 8'-8"FLAT CLG. <br />2 CAR GARAGE <br />CARPET <br />I I I <br />8'-8" FLAT CLG. <br />I I I <br />I I I <br />4'-0" 6'-2" 6-6" <br />4'-8" 20'-8"ie <br />I I I <br />I I <br />EDGE OF SLAB 2" <br />� <br />00 <br />I <br />O <br />I <br />- <br />L----------J <br />BEYOND WALL <br />o <br />I <br />I <br />I I <br />Y <br />i-------------� <br />3 36 36 3 <br />< <br />I uu <br />O= <br />I <br />is <br />o <br />CC <br />I <br />I <br />_ <br />-�- <br />S3 <br />I w <br />I p <br />I I <br />O M <br />t <br />cib <br />B'-8' <br />FL <br />T C <br />G. r; <br />- -- <br />1 <br />- <br />2 <br />6880 <br />I <br />-�- <br />1.9 <br />668,13 F. <br />REF.2x6 <br />WALL <br />" Z' <br />- <br />PANTRY - <br />- <br />L------------ <br />L----- --- <br />L <br />-OPT.- <br />0 <br />16" DEEP _ <br />G <br />5-SH _ <br />CV <br />J <br />S6 <br />)TYP @ 2 STORY <br />H.134 <br />5'-0" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />"* SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />184X25} <br />S.H. <br />13 <br />20 X 38 J <br />18 J X 371 <br />S.H. <br />14 <br />20 X 501 <br />18 4 X 50 <br />S.H. <br />15 <br />20X63 <br />184X62} <br />S.H. <br />16 <br />20X72 <br />184X71 j <br />S.H. <br />1112 <br />271/4X26 <br />26X254 <br />S.H. <br />1H3 <br />271/4X38 <br />26x37 <br />S.H. <br />11-14 <br />274X501 <br />26x50 <br />S.H. <br />11-15 <br />27 X63 <br />26X621/2 <br />S.H. <br />11-16 <br />27 X72 <br />26X711/2 <br />S.H. <br />22 <br />37 j X 26 <br />36 } X 25 1/2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 j <br />36 j X 50 <br />S.H. <br />25 <br />37 j X 63 <br />36 4 X 62 1/2 <br />S. H. <br />26 <br />37 J X 72 <br />36 } X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 X 25 } <br />S.H. <br />33 <br />54 X 38 J <br />52 J X 371 <br />S.H. <br />34 <br />54 X 501 <br />52 4 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 ni <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening, <br />M 1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed, Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />DA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />O <br />+26.6 / -28.0 <br />O <br />+26.6 / -32.2 <br />O <br />SEE SN SHEET O SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />I1111111111111111 - = <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 1113111 <br />1ST FLOOR LIVING AREA 1093 <br />2ND FLOOR LIVING AREA <br />1489 <br />LIVING TOTAL 2582 <br />GARAGE 427 <br />FRONT ENTRY 35 <br />TOTAL AREA 3044 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />K <br />Cl) <br />0 <br />CD <br />- o <br />z <br />z <br />Q <br />J <br />r% <br />U) zCZIn <br />U <br />Q) <br />C <br />4--J <br />W <br />O W <br />0 <br />0 <br />Cl) <br />U <br />o <br />m N <br />W E <br />F-- <br />a)M <br />01 c� <br />co <br />= <br />O o 0 <br />U <br />r�� <br />15 co <br /><L rn <br />o <br />C. v <br />rn < o <br />B D. <br /><. <br />N <br />.w O M N <br />o O N <br />Lu <br />Z W z <br />U) <br />Ir- <br />W <br />io W <br />ZN��,Q a� <br />um <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNARI <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0o <br />t%1 <br />W� <br />z< <br />f� <br />UzaO <br />U U <br />z < dQ <br />w <br />Z <br />o w z <br />QU <br />J <br />uj <br />�o <br />z z <br />ro <br />O <br />2:z <br />�\ <br />O_j <br />OZ <br />Z <br />~ <br />a <br />0 <br />�W <br />U <br />L ^ , <br />oo0 <br />aur- <br />FO <br />o <br />< U< <br />o< <br />ULn� OC l <br />* <br />N <br />z<�a <br />L-U,a <br /><< CC <br />g�o <br />Z <br />Z <br />rl <br />�O <br />Ce(Y0ti <br />W <br />J <br />Lr) <br />rl <br />W <br />Q <br />W <br />z <br />=Uz= <br />o <br />U <br />g ;-< <br />o <br />T00 -4 <br />Z <br />boo <br />r) <br />U <br />O <br />4Z <br />W <br />J �, <br />z <br />SCALE : AS NOTED <br />DATE : 7/26/2019 <br />TECH: FMALDONADO <br />VERSION No' 5al <br />SHEET NO. <br />1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.