My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3225 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3225 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 2:23:34 PM
Creation date
2/28/2025 11:05:54 AM
Metadata
Fields
Template:
Building Plans
Street #
3225
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
22100
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
111_I 1 1 1 <br />ON <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />I <br />WEATHERPROOF DUPLEX OUTLET <br />�&GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />LIrlh <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24. <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />l@) <br />RECESSED LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94—/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />opper to Iignts & outlets <br />opper to 20 amp clos <br />copper to WH <br />copper to Dryer <br />t Alu <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />O EXHAUST FAN <br />;Q EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) FC SYSTEM <br />kP PUSH BUTTON SWITCH (OPTIONAL) <br />i0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />t <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />A9 <br />(1) PHONE LINE, (1) DATA PORT <br />UPPER ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Z C <br />_ <br />Z <br />Z <br />Q <br />t1 <br />U) zC:nV) <br />0 <br />W cn <br />4—J LU <br />�V — <br />OLU <br />c <br />Ur) <br />o <br />f� U <br />g p. <br />m N <br />W <br />E <br />a) M <br />CD (+) <br />N-0O M <br />S m <br />O a N <br />U <br />Q rn <br />J__ LL <br />o <br />av <br />v <br />rn < o <br />Al I <br />N `O <br />N <br />v N <br />LE <br />�N� <br />Z LU z � z° <br />W <br />� <br />U <br />LU <br />W V ¢ t Z <br />a <br />0 ���� � z <br />_ <br />t9 N o�?5 m m <br />M Win' <br />LL Z a <br />W NQr c <br />WWW.FDSENG.COM <br />rn <br />0 <br />N <br />00 <br />0 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Oz <br />LU <br />za <br />Z <br />ZZg <br />LUQ C lox- <br />a <br />zo°0 <br />=oZ <br />J <br />Lu W <br />U <br />W <br />Ow�o <br />V N <br />CL o <br />Z $ <br />��/ <br />i Z <br />LL <br />^ <br />LUy <br />Z <br />Q <br />W <br />O <br />QaJ <br />U <br />Ln <br />O8o <br />jr <br />U_ <br />QW <br />W LL <br />O Z <br />IfP <br />it <br />Z <br />f 6 <br />UOca <br />o< <br />J <br />N <br />r� <br />N <br />Q <br />Z<OZ <br />QQw <br />Q <br />°��0 <br />2 0 <br />Z <br />U- <br />W tj <br />J <br />r-I <br />W <br />Q <br />di <br />� <br />Z <br />< Z <br />Q <br />Iwo <br />00 <br />Z <br />�o <br />m <br />� <br />Z <br />: <br />U <br />_ <br />JZ <br /><UJ <br />d <br />U-) <br />o <br />SCALE : AS NOTED <br />DATE : 7/26/2019 <br />TECH: FMALDONADO <br />VERSION NO- 5ol <br />SHEET NO. <br />4.1 <br />