Laserfiche WebLink
COND. COND. <br />0 <br />14'-0' RIDGE VENT <br />N <br />RIDGE <br />I <br />O <br />fn <br />G�<<F <br />O <br />N <br />� <br />T <br />4'-0' ROOF VENT <br />RIDGE <br />a <br />N O <br />to <br />J <br />� <br />SLOPE 5:12 SLOP <br />:12 <br />�A <br />I <br />.Q <br />Q y�A <br />N <br />r a <br />� Q <br />J <br />a <br />O <br />N <br />T <br />ROOF <br />PLAN_ <br />SCALE: )/4"=1'-0" <br />ATTIC VENTILATION CALCULATIONS - Al <br />ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED <br />1/150 Rule Ridge <br />1/300 Rule Off -Ridge <br />(No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. <br />Req.) (Ft.) <br />Total <br />Ventilation <br />ATTIC Provided <br />SPACE SQ. FT. Total SQ. SQ. FT. SQ. IN. of by Upper <br />SQ. IN. of of ventilation to Ventilators <br />ventilation of vented IN. of vented be provided SQ. IN. of SQ. IN. of See Elev <br />required soffit ventilation soffit by upper Ventilation Ventilation ( ) <br />needed required needed ventilators <br />Main 0.000000 0.000000 <br />Floor 0 0 0 0 0 0 0.0 <br />(Zone 1) 0.0 0.0 <br />Upper 9 2.000000 <br />Floor 1535 1474 211 737 53 368 411.0 <br />(Zone 2) 135.0 276.0 <br />"NOTE"' <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />wad <br />UQ)M M <br />) <br />CZ <br />c-co <br />LL LU <br />, <br />umi <br />10 <br />5ol <br />N <br />00 <br />Cl- <br />0 <br />0 <br />s <br />cz <br />S <br />0 <br />N <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ Portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />da Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />ng area may be reduced to 1/300 provided that at least 40% <br />ion of <br />shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />vents. <br />*'CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN*" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS - 15 SO. IN. OF NET FREE AREA /LINEAR FT. <br />• OFF -RIDGE VENTS - 138 SO. IN. OF NET FREE AREA /UNIT <br />• SOFFIT VENTS - 7 SO. IN. OF NET FREE AREA ! SO. FT. <br />N <br />00 <br />Cl- <br />0 <br />0 <br />s <br />cz <br />S <br />0 <br />N <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ Portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />da Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />ng area may be reduced to 1/300 provided that at least 40% <br />ion of <br />shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />vents. <br />*'CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN*" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS - 15 SO. IN. OF NET FREE AREA /LINEAR FT. <br />• OFF -RIDGE VENTS - 138 SO. IN. OF NET FREE AREA /UNIT <br />• SOFFIT VENTS - 7 SO. IN. OF NET FREE AREA ! SO. FT. <br />O <br />Z ch <br />— O <br />Z cry <br />z <br />a <br />