My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3242 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3242 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 4:33:04 PM
Creation date
2/28/2025 11:06:03 AM
Metadata
Fields
Template:
Building Plans
Street #
3242
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
22105
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KITCHEN <br />� SEE PLAN FOR LANDING DEPTH � <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1, <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM OI <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENE <br />LANDING FOF <br />STRINGERS I <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />c0 <br />00 <br />BATH 2 <br />" Knees 11 <br />2x8 LEDGER #2 SYP w/ <br />(3) 16d NAILS TO STUD <br />@ 16" O.C. <br />in <br />KITCHEN <br />2x6 BEAM <br />SLOPED CEILING - <br />TO MAINTAIN 7'-5" <br />HEADER HEIGHT <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16" O.C. w/ SIMPSON A35 <br />CLIP OR LUS26 HANGER TO <br />LEDGER <br />2x12 HDR. w/ (3) 2x STUDS AT <br />EA. END FOR BEARING <br />STANDARD (3) 2X12 <br />STRINGERS W/ SIMPSON A35 <br />CLIP TO HDR. <br />1x TREADS (TYP.) <br />CONT. <br />HANDRAIL <br />� <br />I <br />�l <br />THRUST BLOCK SECURED TO <br />SLAB w/ 1/4"X3 1/2" TAPCONS <br />@ 16" O.C. <br />MIRROR <br />0 <br />Ln <br />CLL. 0 's � .8 <br />I 1 4 <br />5 <br />UJ <br />1 <br />CD <br />QLU <br />) <br />Ln <br />Ln <br />5al <br />OWNER'S BATH <br />0 <br />co <br />0 <br />N <br />PRF-FNG FI 00R .10IRT W/ 121 <br />KITCHEN ISLAND <br />INTERIOR ELEVATIONS <br />SCALE: 1 /2"=1'-0" <br />I U I AL III== IU-U 3VW <br />(16) RISERS AT 7 9/16" <br />10" TREADS w/ 1" NOSING <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 <br />inch and not more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing <br />projection shall not exceed the smallest nosing projection by more than 3/8 inch between two stories, including <br />the nosing at the level of floors and landings. Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located <br />more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to <br />the edge of the open side. Required guards at open -sided walking surfaces, including stairs, porches, balconies <br />or landings, shall be not less than 36 inches in height as measured vertically above the adjacent walking surface <br />or the line connecting the leading edges of the treads. Required guards shall not have openings from the walking <br />surface to the required guard height that allow passage of a sphere 4 inches in diameter. <br />Under -stair protection: <br />Enclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the <br />enclosed side with 1/2-inch gypsum board. <br />TAIR SECTIO <br />SCALE: 1 /2"=1'-0" <br />� o � <br />O <br />zo <br />�Ja <br />z <br />Q <br />a <br />� w <br />V — <br />O W � <br />U mo <br />~ C f0 M <br />= y! OOo <br />\ yuS L U. OD <br />/U f0N <br />� � <br />QO <br />Q Of V7 � R <br />N �O <br />N S <br />Z W N�Z ti z <br />� j tJi <br />W " <br />in Z V OgN�� <br />o <br />� .FDS$SVG t0I' ' <br />r:�7 ai <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 <br />Tampa, FL 33607 <br />www.LennarTampa.corn <br />�o <br />w� <br />Z2Z Q <br />Qf <br />f <br />Uz�O <br />gU 1� <br />W� <br />J <br />QQQ 6o <br />W } Qo <br />Q U <br />ZW <br />0 A Uo�g <br />� N L0 <br /><Z <br />J �In-{ 6J � z <br />LLJ � ~ a <br />N Z Z�=�g <br />d <br />m ck Z � aW <br />SCALE : AS NOTED <br />DATE : 8/8/2019 <br />TECH: FMALDONADO <br />VERSION NO. <br />SHEET NO. <br />2.0 <br />OWNER'S BATH <br />0 <br />co <br />0 <br />N <br />PRF-FNG FI 00R .10IRT W/ 121 <br />KITCHEN ISLAND <br />INTERIOR ELEVATIONS <br />SCALE: 1 /2"=1'-0" <br />I U I AL III== IU-U 3VW <br />(16) RISERS AT 7 9/16" <br />10" TREADS w/ 1" NOSING <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 <br />inch and not more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing <br />projection shall not exceed the smallest nosing projection by more than 3/8 inch between two stories, including <br />the nosing at the level of floors and landings. Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located <br />more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to <br />the edge of the open side. Required guards at open -sided walking surfaces, including stairs, porches, balconies <br />or landings, shall be not less than 36 inches in height as measured vertically above the adjacent walking surface <br />or the line connecting the leading edges of the treads. Required guards shall not have openings from the walking <br />surface to the required guard height that allow passage of a sphere 4 inches in diameter. <br />Under -stair protection: <br />Enclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the <br />enclosed side with 1/2-inch gypsum board. <br />TAIR SECTIO <br />SCALE: 1 /2"=1'-0" <br />� o � <br />O <br />zo <br />�Ja <br />z <br />Q <br />a <br />� w <br />V — <br />O W � <br />U mo <br />~ C f0 M <br />= y! OOo <br />\ yuS L U. OD <br />/U f0N <br />� � <br />QO <br />Q Of V7 � R <br />N �O <br />N S <br />Z W N�Z ti z <br />� j tJi <br />W " <br />in Z V OgN�� <br />o <br />� .FDS$SVG t0I' ' <br />r:�7 ai <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 <br />Tampa, FL 33607 <br />www.LennarTampa.corn <br />�o <br />w� <br />Z2Z Q <br />Qf <br />f <br />Uz�O <br />gU 1� <br />W� <br />J <br />QQQ 6o <br />W } Qo <br />Q U <br />ZW <br />0 A Uo�g <br />� N L0 <br /><Z <br />J �In-{ 6J � z <br />LLJ � ~ a <br />N Z Z�=�g <br />d <br />m ck Z � aW <br />SCALE : AS NOTED <br />DATE : 8/8/2019 <br />TECH: FMALDONADO <br />VERSION NO. <br />SHEET NO. <br />2.0 <br />