My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3242 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3242 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 4:33:04 PM
Creation date
2/28/2025 11:06:03 AM
Metadata
Fields
Template:
Building Plans
Street #
3242
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
22105
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY.' <br />BON <br />TERMINATIOP <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Dpper to lights 3 outlets <br />upper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />t Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />2 <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />�24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUSTFAN <br />� <br />Or <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />_Q <br />ELECTRIC PANEL <br />_`...I <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />G9 <br />(1) PHONE LINE, (1) DATA PORT <br />COND. COND. <br />DISCONNECT <br />WP <br />GFI <br />PATIO <br />WP <br />GFI <br />I I I I <br />I I I I I <br />I I w <br />I <br />— — --- _.— <br />_ _ _ <br />-- <br />ROUGH -IN FOR <br />_ I <br />OPT. CLG. FAN/ <br />\ <br />LIGHT PRE -WIRE <br />.� /� n A L` /� <br />r7'�1YTIL I TW <br />�FI <br />TO2ND <br />ROUGH -IN FOR 1 <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I WP <br />7 <br />GFI <br />db <br />----------- <br />ENTRY, <br />FOYER <br />\ <br />C.M <br />db <br />3 <br />—� <br />......... <br />------- <br />0 <br />to <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />PENDANT AS <br />\PER SPECS / <br />DININ OOM <br />I FI I <br />---- — --- <br />--- <br />REF. <br />OPT. <br />11GFI • X <br />W.H. XI @ 44" <br />A.F.F. <br />0 F------------ <br />I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />I <br />� I <br />GFI @ 44" GFI FOR <br />A.F.F. GAR. DOOR I <br />� / 1 <br />� � I <br />I <br />� / I <br />I <br />I <br />I <br />GFI <br />I <br />VERIFY LOCATION L_IRRIGATION _____ <br />ELECTRICAL PANEL r GFI @ 44" A.F.F. <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=1'-0" <br />r-, l�J <br />O <br />U V <br />Z o <br />Z <br />=M0 <br />Q <br />d <br />U) z0 <br />0 <br />w <br />QX <br />o <br />Ow <br />5 <br />U <br />o n CON <br />W <br />~ <br />Np� M <br />C to M 0 <br />' <br />= <br />O O IN <br />L� <br />t" 0 <br />CO ar <br />Qrn <br />�gv <br />(I Q o <br />(! <br />N N <br />v or!(O h N <br />MM # 00 <br />Z W N z rs' Z <br />5_ <br />� `s <br />101: �, <br />LUtu <br />�< <br />in Z <br />r" <br />0 <br />F,�� m m <br />W a LL °n <br />WWW.FDSENG.COM <br />rn <br />0 <br />CV <br />O <br />CD <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seat. <br />LENNAR <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />�o <br />�a <br />f17 <br />ran <br />Z I0 <br />U <br />Z Q <br />}� <br />i4. _ <br />w <br />Q <br />E3 <br />� <br />I--- <br />o <br />Z <br />> <br />Z <br />DC <br />n <br />Q <br />LU <br />w <br />1..iL <br />_ <br />W <br />U <br />= <br />\� <br />O <br />W <br />o <br />LL <br />L <br />z <br />9-- <br />ZW <br />N <br />N <br />a <br />d.Lu< <br />Lu <br />Z <br />&',� <br />-I <br />w <br />a <br />W <br />Q <br />Z <br />-Z'r <br />E-gU <br />gig <br />Z <br />N.�4 <br />r- <br />�ZzS <br />o <br />Z <br />Q <br />Q <br />�W <br />^O <br />o <br />SCALE : AS NOTED <br />DATE : 8/8/2019 <br />TECH: FMALDONADO <br />VERSION NO. 5ol <br />SHEET NO. <br />4.0 <br />