My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3251 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3251 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 2:41:10 PM
Creation date
2/28/2025 11:06:10 AM
Metadata
Fields
Template:
Building Plans
Street #
3251
Location
Lytton Hall Dr
Contractor
Lennar Home
Building Plans - Permit #
21942
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />1'-0" <br />---— I -- -- I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -- —I—: <br />ICI � 0 ❑EI��M <br />i�0 o0 <br />D�a -iJl L�] 00 <br />15'-0" RIDGE VENT <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />T.O.M. <br />HDR HGT. <br />6" FASCIA <br />(TYP) <br />TEXTURED —� <br />°O oQ CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />F.FL. <br />12 <br />5� <br />12 <br />�5 <br />HEEL <br />12 <br />5� <br />F4 T.O.M. <br />----------------- <br />14'-0" RIDGE VENT <br />HDR HGT. <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.0 <br />(TYP.) <br />— — — F. FL. <br />12 <br />�5 <br />FRONT ELEVATION - Al <br />SCALE: 1 /4"=1'-0" <br />2'-0" <br />RIGHT ELEVATION - Al <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA/ LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />C9 <br />z M <br />0 <br />�o <br />z N <br />3 <br />z' <br />r% <br />13 <br />C: <br />C <br />w <br />�V — <br />Ow <br />E <br />v I ~ <br />N M <br />m N <br />W <br />I--- p <br />N - <br />C - M <br />= N <br />p N <br />0RIM <br />U 2� <br />�s"o°Oo <br />I CID <br />L� le) <br />¢ <br />oo <br />Qv <br />M< ci' <br />B ®® <br />N�a <br />=Jl <br />N N <br />rn cfl w <br />M ONO <br />UMUIU) <br />coz <br />Lu a m 11 ! a <br />W <br />Q Zak%i <br />o ca <br />ZZ //yamy N (] ►at <br />=. �wwIV G. <br />U +� �RV <br />L <br />" F <br />�OFE" <br />S,O <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L E NAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />OZ <br />LU <br />zn <br />E F <br />u) <br />Lu <br />z <br />zoo <br />O <br />z uj : � <br />�0LUz <br />� J <br />000 <br />UJ 04 O <br />U �i Q <br />LU <br />z <br />J <br />Qz <br />g z <br />Q <br />z <br />a <br />U <br />U <br />= <br />W� <br />p�z <br />o <br />J <br />z <br />O <br />UO <br />0 K a <br />U <br />0!LL <br />N <br />Z W � <br />< <br />d" <br />Q¢�r< <br />p� <br />U <br />W <br />z <br />a <br />a � <br />J <br />,�-I <br />W <br />Q <br />W <br />z <br />U <br />��O <br />IceLu fin. Z <br />. ko^ <br />7��1 <br />� <br />z <br />�oS <br />CO <br />Ck <br />� <br />= <br />a z <br />SCALE : AS NOTED <br />DATE : 07/08/2019 <br />TECH: FM <br />VERSION N0. 4mO <br />SHEET NO. <br />3.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.