My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3263 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3263 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 2:52:04 PM
Creation date
2/28/2025 11:06:20 AM
Metadata
Fields
Template:
Building Plans
Street #
3263
Location
Lytton Hall Dr
Contractor
Lennar Home
Building Plans - Permit #
21945
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOLD UP WEATHER <br />RESISTIVE BARRIER & WEATHER RESISTIVE <br />TEMPORARILY SECURE BARRIER WINDOW UNIT <br />WEATHER DOOR ROUGH OPENING SLOPE <br />RESISITIVE 0.3 in: 12.0 in <br />BARRIER WOOD FRAME CONSTR. <br />•V TAPE EXTERIOR SELF -ADHERED FLASHIN 3/4"A" BEAD OF CONSTR. (O.6 Cm : 30.5 Cm) <br />3 SHEATHING BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND RETURN <br />WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND <br />"�EMBLBDN"NOON OR EQUAL WEATHER PROOF CAULKING EXTERIOR <br />z � CEMT. FIN. <br />Q <br />�- WEATHER SELF -ADHERED FLASHING BUILDING PAPER <br />2 ' RESISITIVE <br />BARRIER SEAL TOPS OF JOISTS I WIRE LATH <br />UNDER DECKING SUBFLOOR <br />SELF -ADHERED FLASHING (SEE DETAIL WP07) " <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive RIM JOIST <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier 1 1 <br />BE USED. 3. Fold weather resistive barrier back over head 2 2 O <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />FLANGED WINDOW , FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER EXTERIOR DOOR WITH DECK - SECTION A , CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />EXTERIOR SHEATHING MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />3/4"-1" BEAD OF CONSTR. NEEDED IN CORNERS ADHESIVE <br />EXTERIOR SHEATHING INSTALL SELF -ADHERED THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE FLASHING SELF -ADHERED FLASHING <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) <br />REFER TO TECHNICAL SCORED <br />LETTER ON CHEMICAL O RELEASE PAPER <br />COMPATIBILITY <br />SELF -ADHERED FLASHING (BEFORE FOLDING, SCORE <br />SELF -ADHERED FLASHING, r RELEASE PAPER TO EXPOSE <br />EXTEND A MINIMUM 6" ADHESIVE AS SHOWN) <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />2 3 ' �J <br />SECTION -A (SEE DETAIL WP02)� <br />L-- SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />NAILING FLANGE 1 <br />DO NOT FLASH OVER 2 SEAL TOPS OF JOISTS <br />BOTTOM NAILING p UNDER DECKING <br />FLANGE O (SEE DETAIL WP07) <br />T., <br />m <br />P <br />c <br />s <br />0 <br />t2 <br />to <br />LO <br />I <br />c <br />i <br />3 <br />a <br />N <br />E <br />E <br />0 <br />c <br />I'u <br />i <br />L� <br />E <br />0 <br />c <br />c41 <br />0 <br />a. <br />a <br />z <br />H <br />I <br />Y <br />x <br />J <br />LZ <br />rn <br />N <br />oho <br />Go <br />0 <br />a <br />rn <br />N <br />00 <br />00 <br />NOT USED <br />in <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />rv�anna i uwi m.�a <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />E <br />AM <br />Q <br />SELF-ADHER <br />n <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />V <br />PLASTER STOP <br />CONTINUOUS BACKER <br />ROD & SEALANT <br />A <br />1 <br />2 <br />SELF -ADHERED FLASHING <br />PATCH <br />,HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS GAP IS A RESUL <br />NATURAL SHRINKAGE <br />DO NOT SEAL. <br />DRIP SCREED PLASTI <br />ACCESSORY <br />me <br />SOFFIT/CANTILEVER <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />-7 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stud <br />FOUNDATION WEEP SCREED <br />LEGEND <br />SELF ADHERED FLASHING (SAF) -0 o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - - <br />BOND BREAK WEATHER RESISTANT BARRIER - - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS <br />TRUCTURAL FRAMING <br />TRUCTURAL SHEATHING <br />TRIP OF SAF <br />RAINAGE PLANE WRB <br />DND BREAK WRB <br />F LATH <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as (Din each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to comer <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />- 7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />.Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />O <br />0 <br />Z g <br />Z <br />Z <br />n <br />Z <br />Ln U' <br />� w <br />�V - <br />0 LL, <br />N <br />Ln <br />U <br />L LJ <br />mo <br />4) <br />■® _$ <br />U <br />OWN <br />�oD <br />12ti <br />¢rn <br />�8nv <br />Atl <br />B Ds <br />"� 1.*1 <br />_ N N <br />N0z <br />�. Z' <br />W Q ri 'L <br />Us U <br />Z -sNrn O <br />Q <br />'t=e g r! 2 m <br />T �, m <br />Z H MEN <br />LL D <br />W Q N¢M1 c <br />U <br />O V O <br />11 U <br />WWW.FDSENG.COM <br />C" <br />N <br />O <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />rord� <br />Lo <br />Z Q <br />W Q OC O' <br />U u��Z1O0 <br />ZZ <br />OSW <br />2 �.- <br />ouzo <br />Q) <br />F- <br />CU <br />O <br />�3 <br />O <br />Cr <br />a- <br />1= <br />g i . <br />oLU <br />Q <br />�6�yy <br />W$�mpSp <br />vv00ZCQ <br />.�y <br />N <br />Z <br />_J <br />Ln <br />di <br />i3 <br />a <br />rA <br />W <br />X <br />Q <br />Z <br />� <br />Z <br />U <br />Lu Z <br />S <br />rl Ln <br />ko <br />Ln <br />ZZ <br />�ui <br />0 <br />� <br />J <br />= <br />.-♦ <br />a <br />Ul <br />o <br />SCALE : AS NOTED <br />DATE : 08/07/2019 <br />TECH: FM <br />VERSION NO. 4n0 <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.