My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3263 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3263 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 2:52:04 PM
Creation date
2/28/2025 11:06:20 AM
Metadata
Fields
Template:
Building Plans
Street #
3263
Location
Lytton Hall Dr
Contractor
Lennar Home
Building Plans - Permit #
21945
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H. <br />AC PAD ------------1---- <br />W.I.C. <br />00 8'-0" FLAT CLG. <br />CARPET = <br />-------R&S ---7 -- <br />o A <br />r S3 <br />TYP @ 1 STORY <br />I <br />OWN IS <br />SUIT <br />8'-0" FLAT C G. <br />CARPET <br />I <br />(4) 2x4 #2 SYP ~ G <br />STUDS W/USP <br />HTT4@ BASE S3 <br />4-SH <br />2668 <br />2668 <br />O <br />25-SH <br />EGRESS <br />BEDROOM 2 <br />8'-0" FLAT CLG. <br />CARPET <br />ib <br />tV <br />3' <br />O <br />25-SH <br />I <br />EGRESS <br />I <br />BEDROOM <br />I <br />8'-0" FLAT CLG. <br />I <br />CARPET <br />Calall <br />�I <br />00 <br />I <br />I <br />I <br />I <br />o <br />� <br />I <br />I <br />I <br />11'-10" <br />TO <br />I <br />HALL <br />1�1■�Ijl <br />�1�\III <br />BEDROOM 4 <br />8'-0" FLAT CLG. I U) q9 <br />UJ CARPET cc M O <br />O <br />W <br />I <br />1 LE �I <br />I <br />K 2-CAR GARAGE <br />S3 8'-0" FLAT CLG. <br />FIBERGLASS I EDGE OF SLAB 2" <br />SURROUND BEYOND WALL•" <br />T 8 <br />t I DRYER VENT <br />6-0" V-7§8" I G HAS N BOX @ THRU ROOF <br />36' A F F R&S I <br />i coo <br />1" <br />N <br />SUR%OUND <br />.0 <br />SHOWER <br />� i <br />awl1���■��m���1 <br />�11�1®��IIrl��l <br />Mi=O=i����..1 <br />I S3 -- ---- <br />9'-0" I 3'-8" 2'-8" 4'-3" 6-10" T_7" DPT. OPT. D <br />e <br />I <br />I CO -0" LA CL <br />2.12 SLOPE. I I U 11 <br />CEILING I - Ax <br />_ INIv� I <br />I 868 1= a I <br />r------------------------------------ II 11 <br />T FAMILY ROOM M °` <br />VAULT. CLG. CAFE <br />i CARPET VAULT. CLG. 1 <br />30'-0" CARPET 4 -13" 068 1 <br />B <br />a ENTRY <br />I <br />JZ _ Y °° l <br />CNUJ <br />ILE I I 8'-0" FLAT CLG. <br />. <br />S3 <br />35-SH <br />O <br />16'-3" <br />low <br />4068 B.F. II„' <br />- - - <br />-R&S - - ---- <br />F--------- - <br />I D <br />I S3 1 <br />I <br />I <br />I <br />I <br />I 1 <br />I <br />I <br />I E' <br />I � <br />I I <br />I <br />I <br />I <br />I <br />I <br />I I <br />I <br />I <br />I <br />I <br />I 1 <br />I <br />I <br />I <br />I <br />I I <br />I <br />I <br />L--------- -- <br />I <br />9*1 <br />,CO] <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2' <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) -1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 4 X 25 } <br />S.H. <br />13 <br />20 X 38 j <br />18 J X 37 j <br />S.H. <br />14 <br />20 X 50 j <br />18 J X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 J X 62 j <br />S.H. <br />16 <br />20X72 <br />18jX71} <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />11-13 <br />271/4X38 <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 50 i <br />26 x 50 <br />S.H. <br />11-15 <br />27jX63 <br />26X621/2 <br />S.H. <br />11-16 <br />27}X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 j X 25 1/2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 j <br />36 4 X 50 <br />S.H. <br />25 <br />37jX63 <br />36}X621/2 <br />S.H. <br />26 <br />37JX72 <br />36}X711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 j WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 4 <br />S.H. <br />33 <br />54 X 381j <br />52 } X 37 1 <br />S.H. <br />34 <br />54 X 501 <br />52 4 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 j X 62 j <br />S.H. <br />36 <br />54 X 72 <br />52 } X 71 4 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />� o <br />N <br />N <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />DA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />( <br />+26.6 / -28.0 <br />) <br />+26.6 / -32.2 <br />OG <br />SEE SN SHEET OH SEE SN SHEET <br />wilff <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />MASONRY HGT. @ 9'4" A.F.F. <br />TYP. 2x FRAME WALL <br />INTERIOR BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION <br />1ST FLOOR LIVING AREA 1817 <br />LIVING TOTAL 1817 <br />GARAGE 427 <br />FRONT ENTRY 32 <br />TOTAL AREA 2276 <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />B EXT FRAME 2 x 6 R-1KRAFT FACED <br />FIRST FLOOR PLAN <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />11�� GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />SCALE: 741_ 11-011 (GARAGE / LIVING) <br />GU <br />O <br />Z <br />z� <br />z <br />a <br />U, Z <br />Q0cn <br />W <br />A <br />p <br />•O W <br />ZD <br />♦� ' ` <br />_OOOm N <br />c <br />N 1 C%1 <br />= Ql <br />C) <br />O O <br />00 <br />¢ rn <br />C. <br />� R <br />obi Q o <br />MID. <br />10 <br />N- N <br />U) Z Wo z raa, z <br />a w <br />W <br />�\\ N Qav,®® <br />LLPt A i2 in <br />P r Ng��O'E7 <br />co <br />•,• <br />., F 1.0�` <br />�, <br />FESSX <br />��//11I111111` <br />To the best of fhe Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />o <br />W <br />Zg <br />Edo <br />z <br />z <br />�89W <br />J <br />oLL�I��.o <br />OFti0 <br />A <br />uj <br />OZ <br />Z <br />LL <br />0 <br />U <br />uz <br />-RO <br />"S <br />i <br />v' <br />va°°$ <br />(� <br />�-•� <br />W <br />W <br />Q <br />Z <br />'""I <br />3 <br />J <br />rl <br />W <br />Q <br />W <br />2: <br />Z <br />az <br />�a� <br />,--I <br />Z <br />yl-j <br />1 o S <br />M <br />W <br />6 <br />g <br />W <br />W <br />° <br />o <br />SCALE : AS NOTED <br />DATE : 08/07/2019 <br />TECH: FM <br />VERSION NO. 4w0 <br />SHEET NO. <br />1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.