<br />Re: Wood Construction Connector Compliance for 2015 International Codes & 2017 Florida Codes
<br />To Whom It May Concern
<br />Section 2303.5 of the 2015 International Building Code (IBC) and 2017 Florida Building Code (FBC) specifies that
<br />joist hangers shall be tested per ASTM D7147 Tooling and Estabkshing Loads of Joist Hangers. Previous versions of
<br />the IBC and FBC required testing to comply with ASTM D1761 Test Method fir Mechanical Fasteners in Wood. Both
<br />methods determine a connector's allowable load as the lowest of the following:
<br />i. ith Lowest ultimate of three tests (or average of 6) wa safety factor of 3
<br />2. Average bad at 1/8-inch deflection
<br />3. Calculations per American Wood Council National Design Specification for Wood Construction (NDS)
<br />The primary changes in ASTM D7147 are requirements to measure properties of the tested materials, such as steel
<br />strength, fastener strength, and wood specific gravity. The tested ultimate loads must be adjusted when tested
<br />material properties exceed the specified properties.
<br />ICC Evaluation Services QCC-ES) revised AC13 Acceptance Criteria for Joist Hangars and Similar Devices in
<br />October 2018 to incorporate a methodology to evaluate products to tiro 2015 I -Codes. Simpson Strong -Tie is working
<br />on re-evaluating wood construction connector beds to the new standard to update our product evaluation reports to
<br />the 2015 I -Codes. As soon as the updated evaluation reports are completed, we will apply for Florida Product
<br />Approvals.
<br />However, reevaluating a large number of products will take time. While manufacturers work with product certification
<br />agencies to update their wood connector evaluation reports, we recommend that building departments under the
<br />2015 I -Codes and 2017 Florida Codes continue to accept code reports showing compliance to the 2012 and 2014
<br />editions, respectively, until July 2018.
<br />The information in this letter is valid until SG=118 when it will be re-evaluated by Simpson Strong -Tie. Please visa
<br />on�tie.com for additional pertinent information. If you have questions or reed further assistance regarding
<br />this matter, please contact the Simpson Strong -Tie Engineering Department at 800.999.5099.
<br />Sincerely,
<br />SIMPSON STRONG -TIE COMPANY INC.
<br />AP4
<br />Keith Cullum, P.E, LEED AP dw(BDW
<br />Engineer, Southeast U.S. Branch
<br />Page 1 of 1
<br />",- . . 2221 Country Ina McKimay, TX 75M Phorr: 972.542.0320 Fax 972.542.4139 W",4tQ^aoe com
<br />-I✓'
<br />-
<br />`u'
<br />.-4._..: J _ 6 .
<br />Y
<br />y„ y, ... robY �"
<br />`[' .::? '4't.-'MR
<br />ry J` i
<br />1.
<br />Y ..�:j,f, k`MF iu'... 4e /,
<br />A3
<br />FL17244-1
<br />ESR-3455
<br />A23
<br />FL10446.2
<br />ESR-26M
<br />HD210-2
<br />FL17232.3
<br />ESR-3445
<br />HU210.2
<br />FL10856.4
<br />ESR-2549
<br />HD212-2
<br />FL17232.3
<br />ESR-3445
<br />HU212-2
<br />FL10856.4
<br />ESR-2549
<br />HD216
<br />FL17232.3
<br />ESR-3445
<br />HU216
<br />FL10856.5
<br />ESR-2549
<br />HD2163
<br />FL17232.3
<br />ESR-3445
<br />HU216.3
<br />FL10856.1
<br />ESR-2549
<br />HD26
<br />FL17232.2
<br />ESR-3445
<br />HU26
<br />FL10856.3
<br />ESR-2549
<br />HD28-2
<br />FL17232.3
<br />ESR-3445
<br />HU28-2
<br />FL10858.4
<br />ESR-2549
<br />HD410
<br />FL17232.4
<br />ESR-3445
<br />HU410
<br />FL10856.9
<br />ESR-2549
<br />HD412
<br />FL17232.4
<br />ESR-3445
<br />HU412
<br />FL10858.9
<br />ESR-2549
<br />HD610
<br />FL17232.4
<br />ESR-3445
<br />HU610
<br />FL10856.10
<br />ESR-2549
<br />HDO410
<br />FL17241.7
<br />ESR-3444
<br />HUCQ410
<br />FL11468.11
<br />SIM200804
<br />HGA10
<br />FL17699.1
<br />Evaluation Report
<br />HGA10KT
<br />FL11470.4
<br />SIM200803
<br />HGAM10
<br />FL17699.1
<br />Evaluation Report
<br />HGAM10KT
<br />FL11470.4
<br />SIM200803
<br />HHCP2
<br />FL17236.7
<br />ESR-3448
<br />HCP2
<br />FL10447.2
<br />ESR-2551
<br />HTA16
<br />FL17680.4
<br />Evaluation Report
<br />HETA16
<br />FL11473.5
<br />SIM200802
<br />HTA20-18
<br />FL17880.4
<br />Evaluation Report
<br />HETA20
<br />FL11473.5
<br />SIM200802
<br />HTT16
<br />FL17324.2
<br />Evaluation Report
<br />HTT66
<br />FL11496.1
<br />ES-0130
<br />HTT45
<br />FL17324.2
<br />Evaluation Report
<br />HTT22
<br />FL11496.1
<br />ES-0130
<br />HTW16
<br />FL17244.8
<br />ESR-3455
<br />HTS18
<br />FL10458.22
<br />ESR-2613
<br />HTW20
<br />FL17244.8
<br />ESR-3455
<br />HTS20
<br />FL10456.23
<br />ESR-2613
<br />HTW24
<br />FL17244.8
<br />ESR-3455
<br />HTS24
<br />FL10456.24
<br />ESR-2613
<br />HTW30
<br />FL17244.8
<br />ESR-3455
<br />HTS30
<br />FL10456.26
<br />ESR-2613
<br />HTWM16
<br />FL6223.2
<br />Evaluation Report
<br />HTSM16
<br />FL11473.11
<br />SIM200802
<br />HTWM20
<br />FL6223.2
<br />Evaluation Report
<br />HTSM20
<br />FL11473.11
<br />SIM20DB02
<br />HUGT2
<br />FL6223.3
<br />Evaluation Report
<br />HGT2
<br />FL10456.18
<br />ESR-2613
<br />HUGT3
<br />FL6223.3
<br />Evaluation Report
<br />HGT3
<br />FL10456.19
<br />ESR-2613
<br />HUS210-2
<br />FL17232.6
<br />ESR-3445
<br />HUS210-2
<br />FL10856-R4
<br />ESR-2549
<br />HUS212-2
<br />FL17232.6
<br />ESR-3445
<br />HUS212-2
<br />FL10858.11
<br />ESR-2549
<br />HUS26
<br />FL17232.6
<br />ESR-3445
<br />HUS28
<br />FL10858.11
<br />ESR-2549
<br />HUS28
<br />FL17232.6
<br />ESR-3445
<br />HUS28
<br />FL10858.61
<br />ESR-2549
<br />HUS28-2
<br />FL17232.6
<br />ESR-3445
<br />HUS28-2
<br />FL10856.11
<br />ESR-2549
<br />JL24
<br />FL17232.7
<br />ESR-3445
<br />LU24
<br />FL10655.103
<br />ESR-2549
<br />JL26
<br />FL17232.7
<br />ESR-3445
<br />LU26
<br />FL10655.104
<br />ESR-2549
<br />JUS210.2
<br />FL17232.11
<br />ESR-3445
<br />LUS210-2
<br />FL10655.107
<br />ESR-2549
<br />JUS24
<br />FL17232.10
<br />ESR-3445
<br />LUS24
<br />FL10655.109
<br />ESR-2549
<br />JUS26
<br />FL17232.11
<br />ESR-3445
<br />LUS26
<br />FL10655.111
<br />ESR-2549
<br />JUS26-2
<br />FL17232.11
<br />ESR-3445
<br />LUS26.2
<br />FL10655.112
<br />ESR-2549
<br />JUS28
<br />FL17232.11
<br />ESR-3445
<br />LUS28
<br />FL10655.113
<br />ESR-2549
<br />JUS46
<br />FL17232.11
<br />ESR-3445
<br />LUS46
<br />FL10655.118
<br />ESR-2549
<br />KLEG3
<br />FL17241.15
<br />ESR-3444
<br />LEGS
<br />FL10e67.71
<br />ESR-2615
<br />KST260
<br />FL17244.15
<br />ESR-3455
<br />MST60
<br />FL10852.7
<br />ESR-2105
<br />LSTA12
<br />FL17244.18
<br />ESR-3455
<br />LSTA12
<br />FL10852.4
<br />ESR-2105
<br />LSTA15
<br />FL17244.18
<br />ESR-3455
<br />LSTA15
<br />F00852.4
<br />ESR-2105
<br />LSTA18
<br />FL17244.18
<br />ESR-3455
<br />LSTA18
<br />FL10852.4
<br />ESR-2105
<br />LSTA24
<br />FL17244.18
<br />ESR-3455
<br />LSTA24
<br />FL10852.4
<br />ESR-2105
<br />LSTA30
<br />FL17244.18
<br />ESR-3455
<br />LSTA30
<br />FL10852.4
<br />ESR-2105
<br />LSTA36
<br />FL17244.18
<br />ESR-3456
<br />LSTA36
<br />FL10852.5
<br />ESR-2105
<br />LTS19
<br />FL17219.2
<br />ER-0200
<br />LTT19
<br />FL11496.3
<br />ER-130
<br />LTS20B
<br />FL172192
<br />ER-0200
<br />LTT20B
<br />FL11496.3
<br />ER-130
<br />LTT131
<br />FL17219.2
<br />ER-0200
<br />LTT131
<br />FL11496.3
<br />ER-130
<br />LTW12
<br />FL17244.8
<br />ESR-3455
<br />LTS12
<br />FL10456.29
<br />ESR-2613
<br />LUGT2
<br />FL17240.2
<br />ESR-3447
<br />LGT2
<br />FL11470.7
<br />SIM200803
<br />MP3
<br />FL17244.22
<br />ESR-3455
<br />LS30
<br />FL10446.15
<br />ESR-2606
<br />MP34
<br />FL17244.23
<br />ESR-3455
<br />A34
<br />FL10446.3
<br />ESR-2606
<br />MP4F
<br />FL17244.24
<br />ESR-3455
<br />LTP4
<br />FL10446.19
<br />ESR-2606
<br />MPS
<br />FL17244.22
<br />ESR-3455
<br />LS50
<br />FL10446.16
<br />ESR-26M
<br />MPH3516
<br />FL17240-3
<br />ESR-3447
<br />WM1418
<br />FL10667.86
<br />ESR-2615
<br />MSTA12
<br />FL17244.18
<br />ESR-3455
<br />MSTA12
<br />FL10852.8
<br />ESR-2105
<br />MSTA15
<br />FL17244.18
<br />ESR-3455
<br />MSTA15
<br />FL10852.8
<br />ESR-2105
<br />MSTA18
<br />FL17244.18
<br />ESR-3455
<br />MSTA18
<br />FL10852.9
<br />ESR-2105
<br />MSTA24
<br />FL17244.18
<br />ESR-3455
<br />MSTA24
<br />FL10852.9
<br />ESR-2105
<br />MSTA36
<br />FL17244.18
<br />ESR-3455
<br />MSTA36
<br />FL10852.9
<br />ESR-2105
<br />MSTC40
<br />FL17244.26
<br />ESR-3465
<br />MSTC40
<br />FL10852.11
<br />ESR-21D5
<br />MSTC52
<br />FL17244.26
<br />ESR-3455
<br />MSTC52
<br />FL10852.11
<br />ESR-2105
<br />MTW12
<br />FL17244.8
<br />ESR-3455
<br />MTS12
<br />FL10456.33
<br />ESR-2613
<br />MTW18
<br />FL17244.8
<br />ESR-3455
<br />MTS16
<br />FL10456.34
<br />ESR-2613
<br />MTW18
<br />FL17244.8
<br />ESR-3455
<br />MTS18
<br />FL10456.35
<br />ESR-2613
<br />MTW20
<br />FL17244.8
<br />ESR-3455
<br />MTS20
<br />FL10456.36
<br />ESR-2613
<br />MUGT15
<br />FL17240.5
<br />ESR-3447
<br />MGT
<br />FL11470.9
<br />SIM200803
<br />NFM35X12
<br />FL578.2
<br />Evaluation Report
<br />MBHA3.56/1125
<br />FL13904.6
<br />ESR-2616
<br />NFM35X16U
<br />FL578.3
<br />Evaluation Report
<br />MBHA3.56/16
<br />FL13904.6
<br />ESR-2616
<br />PAU44
<br />FL17239.13
<br />ESR-3449
<br />HDU2SDS2.5
<br />FL10441.4
<br />ESR-2330
<br />PAU68
<br />FL17239.13
<br />ESR-3449
<br />GLTV3.516
<br />FL10667.8
<br />ESR-2615
<br />PHD2A
<br />FL17219.3
<br />ER-0200
<br />FGTR
<br />FL11473.2
<br />SIM200802
<br />PHXU3516
<br />FL17241.20
<br />ESR-3444
<br />CS18
<br />FL10852.1
<br />ESR-2105
<br />RFUS
<br />FL6223.5
<br />Evaluation Report
<br />H1
<br />FL10456.5
<br />ESR-2613
<br />RS150
<br />FL17244.27
<br />ESR-3455
<br />H10
<br />FL10456.6
<br />ESR-2613
<br />RT15
<br />FL17236.3
<br />ESR-3448
<br />H10-2
<br />FL10458.7
<br />ESR-2613
<br />RT16.2
<br />FL17236.2
<br />ESR-3448
<br />H10A
<br />FL10456.6
<br />ESR-2613
<br />RT16A
<br />FL17236.2
<br />ESR-3448
<br />H3
<br />FL10456.13
<br />ESR-2613
<br />RT3A
<br />FL17236.3
<br />ESR-3448
<br />H4
<br />FL10456.14
<br />ESR-2613
<br />RT4
<br />FL17236.3
<br />ESR-3448
<br />H5
<br />FL10456.15
<br />ESR-2813
<br />RT5
<br />FL17236.3
<br />ESR-3448
<br />H2.5
<br />FL10456.11
<br />ESR-2613
<br />RT7
<br />FL17236.3
<br />ESR-3448
<br />H2.5A
<br />FL10456.12
<br />ESR-2813
<br />RT7A
<br />FL1723B.3
<br />ESR-3448
<br />H8
<br />FL11470.3
<br />SIM200803
<br />RTBA
<br />FL17236.3
<br />ESR-3448
<br />SP1
<br />FL10456.41
<br />ESR-2613
<br />SPT22
<br />FL17244-30
<br />ESR-3455
<br />SP2
<br />FL10456.42
<br />ESR-2613
<br />SPT24
<br />FL17244.31
<br />ESR-3455
<br />SP4
<br />FL10456.43
<br />ESR-2613
<br />SPT4
<br />FL17244.32
<br />ESR-3455
<br />SP6
<br />FL10456.44
<br />ESR-2613
<br />SPTt3
<br />FL17244.32
<br />ESR-3455
<br />SP8
<br />FL10456.45
<br />ESR-2613
<br />SPT8
<br />FL17244.32
<br />ESR-3455
<br />SPH4
<br />FL10456.46
<br />ESR-2613
<br />SPTH4
<br />FL17244.32
<br />ESR-3455
<br />SPH6
<br />FL10456.47
<br />ESR-2613
<br />SPTH6
<br />FL17244.32
<br />ESR-3455
<br />SPH8
<br />FL10456.48
<br />ESR-2613
<br />SPTH8
<br />FL17244.32
<br />ESR-3455
<br />U24
<br />FL10855.141
<br />ESR-2549
<br />SUH24
<br />FL17232.13
<br />ESR-3445
<br />HHUS28-2
<br />FL10655.3
<br />ESR-2549
<br />THD28
<br />FL17232.16
<br />ESR-3445
<br />HHUS410
<br />FOD655.4
<br />ESR-2549
<br />THD28.2
<br />FL17232.16
<br />ESR-3445
<br />HGUS5.25/12
<br />FL11468.11
<br />SIM200804
<br />THD410
<br />FL17232.16
<br />ESR-3445
<br />HGUS414
<br />FL11468.10
<br />SIM2008D4
<br />THD412
<br />FL17232.16
<br />ESR-3445
<br />HDQ8-SDS3
<br />FL10441.1
<br />ESR-2330
<br />THD612
<br />FL17232.16
<br />ESR-3445
<br />MSTAM24
<br />FL11473.19
<br />SIM200802
<br />THDH414
<br />FL17232.17
<br />ESR-3445
<br />MSTAM36
<br />FL11473,19
<br />SIM200802
<br />UGTS3F
<br />FL2033.1
<br />Evaluation Report
<br />MSTCM40
<br />FL11473.19
<br />SIM200802
<br />UPHDB
<br />FL17219.5
<br />ER-0200
<br />HHETA20
<br />FL11473.9
<br />SIM20D802
<br />-
<br />-
<br />-
<br />LGT3SDS2.5
<br />FL11470.7
<br />SIM200803
<br />-
<br />-
<br />-
<br />LGUM26-2
<br />FL11473.12
<br />SIM200802
<br />PRODUCT APPROVAL SPECIFICATION SHEET (2018) ,January 9, 2019
<br />As required by Florida Statute 553.842 and Florida Administrative Code 96-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the
<br />construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed
<br />products.
<br />Category/Subcategory
<br />Manufacturer
<br />Product Description
<br />Approval Number(s)
<br />Test Pressures
<br />1. EXTERIOR DOORS
<br />A. SWINGING
<br />ThermaTru
<br />Firber-Classic and Smooth -Star (NON -IMPACT)
<br />FL20461.1
<br />+67.0/-67.0 psf
<br />ThermaTru
<br />Firber-Classic and Smooth -Star (NON -IMPACT)
<br />FL20461.6
<br />+67.01.67.0 psf
<br />ThermaTru
<br />Firber-Classic and Smooth -Star (NON -IMPACT)
<br />FL20461.9
<br />+67.0/-67.0 psf
<br />ThermaTru
<br />Firber-Classic and Smoott�Star (NON -IMPACT)
<br />FL20461.14
<br />+67.0/-87.0 psf
<br />ThermaTru
<br />Classic -Craft and Benchmark
<br />FL15225.1
<br />+87.0/-67.0 psf
<br />ThermaTru
<br />Smooth -Star and Benchmark
<br />FL15225.5
<br />+67.0/-87.0 pat
<br />ThermsTru
<br />FiberClassic, Smoothstar, ClassicCraft, Rustic
<br />FL7840.1
<br />+67.0/-67.0 psf
<br />B. SLIDING
<br />MI Wndows and Doors
<br />Series 420
<br />FL15332.1 - FL15332.5
<br />+40.0/-40D psf
<br />PGT
<br />Series 5570
<br />FL251.10
<br />C. SECTIONAL
<br />Clopay Building Products
<br />Residential WlndCode Doors W5 (SX7)
<br />FL15279.37
<br />+30.0/-32.0 psf
<br />Clopay Building Products
<br />Residential WndCode Doors W5 (16X7)
<br />FL15279.53
<br />+30.0/-30.0 psf
<br />Clopay Building Products
<br />Residential WndCode Doors WB (8X7)
<br />FL15279.85
<br />+38.0/-42.0 psf
<br />Clopay Building Products
<br />Residential W ridCode Doors W6 (16X7)
<br />FL15279.102
<br />+37.0/-41.0 pat
<br />D. METAL LOUVERED DRS
<br />Curries Division of AADG, Inc
<br />607,707,727,747,arx1847 Single & Pairs of Doors
<br />FL11537.1
<br />N/A (see inst ant)
<br />2. WINDOWS
<br />A. SINGLE HUNG
<br />MI Windows and Doors
<br />Series 185
<br />FL17499.2
<br />+50.0/-55.0 psf
<br />PGT
<br />Series 55M
<br />FL.239.7
<br />B. HORIZONTAL SLIDER
<br />MI Windows and Doors
<br />Series 188
<br />FL15351.1
<br />+40.0/-50.0 psf
<br />C. FIXED
<br />MI Windows and Doors
<br />Series 185
<br />FL15349.1
<br />+40.0/-40.0 psf
<br />PGT
<br />Series5520
<br />FL243.9
<br />D. MULLION
<br />MI Windows and Doors
<br />Series 5784
<br />FL15353.2
<br />N/A
<br />PGT
<br />Series 55M
<br />FL261.1
<br />N/A
<br />E. OTHER
<br />3. PANEL WALL
<br />A. SIDING
<br />James Hardie Building Prod.
<br />Cemplank Lap Siding and HardiePlank Lap Siding
<br />FL13192.1 - FL13192.2
<br />N/A
<br />B. SOFFITS
<br />Alside
<br />Solid and Vented Soffit
<br />FL15272.1 - FL15272.2
<br />+70.0/-70.0 psf
<br />C. OTHER
<br />4. ROOFING PRODUCTS
<br />A. ASPHALT SHINGLES
<br />GAF
<br />3 Tab, Dimensional
<br />FL10124.1
<br />N/A
<br />B. UNDERLAYMENTS
<br />Tamko
<br />151b Felt Underisyment
<br />FL12328.6
<br />N/A
<br />C. ROOFING FASTENERS
<br />NOT USED
<br />D. ROOF VENTILATORS
<br />Thompson Arch Metal Comp.
<br />Off Ridge Vents
<br />FL16918.1 - FL16918.4
<br />N/A
<br />Florida Metal Products, Inc
<br />Vent RV10
<br />FL21580.3
<br />N/A
<br />Lomanco, Inc
<br />DA-4 Exahust Vent
<br />FL17202.1
<br />N/A
<br />E. ROOFING TILES
<br />Sorel Tile
<br />Villa 900
<br />FL7849.27 - FL7849.28
<br />N/A
<br />Boral Tile
<br />Saxony 900
<br />FL7849.16 - FL7849.20
<br />N/A
<br />F. METAL ROOF
<br />Gulf Coast Supply & Manufacturing, LLC
<br />0.032" Aluminum GulfLok 16" wide roof panel
<br />FL11651.2 R3
<br />N/A
<br />5. SHUTTERS
<br />A. STORM PANELS
<br />Global Protection Products
<br />Galvanized Steel Storm Panels
<br />FL15076.1 - FL15076.2
<br />N/A
<br />All American Shutters & Glass
<br />Galvanized Steel Storm Panels
<br />FL17869.1
<br />N/A
<br />6. STRUCTURAL
<br />COMPONENTS
<br />A. WOOD CONNECTORS/
<br />USP Structural Conn.
<br />see chart
<br />ANCHORS
<br />Simpson Strong -Tie
<br />see chart
<br />B. TRUSS PLATES
<br />ITW Building Components
<br />Alpine Truss Plates
<br />FL1999.1 - FL1999.4
<br />N/A
<br />MTek Industries, Inc.
<br />Truss Plates
<br />FL2197.1 - FL2197.5
<br />N/A
<br />C. ENGINEERED LUMBER
<br />Weyerhaeuser
<br />Rim Board, LVL, PSL, LSL
<br />FL6527.1 - FL6527.5
<br />N/A
<br />D. MATERIAL
<br />Cast -Crete Corp.
<br />High Strength Concrete Lintels
<br />FL158.1
<br />N/A
<br />Commercial Concrete Products, Inc.
<br />High Strength Concrete Lintels
<br />FL1774
<br />N/A
<br />The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the
<br />jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I
<br />understand these products may have to be removed if approval cannot be demonstrated during inspection.
<br />APPLICANT SIGNATURE
<br />DATE
<br />,i
<br />co
<br />_
<br />to
<br />OL
<br />N
<br />U
<br />�\
<br />�{/
<br />c
<br />O
<br />O
<br />CU
<br />�\
<br />CU
<br />Ca
<br />CO
<br />O
<br />O
<br />.L
<br />0
<br />L
<br />O
<br />.w
<br />Cn
<br />a)
<br />t/
<br />Q
<br />Q
<br />C
<br />0
<br />�2
<br />��
<br />8-
<br />.0
<br />VJ
<br />Q
<br />Q
<br />Z
<br />W
<br />J
<br />(�1/)�
<br />V/
<br />CU
<br />M
<br />a<
<br />ICU
<br />W
<br />Z
<br />Z
<br />Q
<br />J
<br />F�
<br />SHEET N0.
<br />PA 1.0
<br />
|