My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3278 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3278 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 3:09:21 PM
Creation date
2/28/2025 11:06:34 AM
Metadata
Fields
Template:
Building Plans
Street #
3278
Location
Lytton Hall Dr
Contractor
Lennar Home
Building Plans - Permit #
21905
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE �, <br />� <br />15/32" CDX <br />m <br />PLYWOOD OR <br />7l16" OSB <br />RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0,280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: " FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER, IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />t <br />+ + <br />+ + <br />+ + . + <br />+ <br />+ <br />+ <br />+ <br />+ t <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ p <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ <br />+6-13" + <br />^++ <br />+ + <br />+ <br />+ + <br />+++ <br />+++ <br />+ 4 <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />q <br />+ + <br />+ + <br />+ + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />++ <br />+++ <br />++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/$" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />1/8" gap <br />o <br />FILL CELL STD. 90° HOOK BOND BEAM <br />Cn <br />Q <br />STD. 90° CONT. #5 <br />CONT. #5 <br />BAR <br />HOOK BAR <br />OOC <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />L <br /># OF 2nd FLOOR <br />Solid block all posts from <br />above to bearing below. <br />STUDS <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. Small 2 min. <br />2" } <br />gap <br />max. 4 max. <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange, <br />4 Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OS6 web stiffener 2" min. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT ) at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or 4" max. <br />- Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVINGY8" GAP @ TOP sides by 6". - Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION top flangeuth cuts. <br />- Birdsmouth cuts. N.T.S. <br />- - Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />Non stacking walls over squash=20 blocks and <br />require additions{ wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or-20 sinker <br />lateral load. nail each side <br />10ES a ring. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 000 <br />5'-0" Q - <br />c� <br />STUB -OUT FOR 1 -011 0 0 <br />GAS METER 0 o LO <br />� U <br />CV � <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY*" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @' 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />'I T-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block / <br />(2x4 minimum) �J <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam J <br />Boise Joist Blocking <br />I l.a 3" (10dl nail. at 6" n c_ <br />Q '/ Provide adequate bearing <br />for each lapped joist. <br />nails SECTION'--" INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />le <br />DO NOT cut, notch <br />or drill flanges <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />king and wall or beam below.*tz <br />—� <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BC16000s® <br />BC16500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s8 <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190s® <br />11-7/ " <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPS( <br />w/(22)' <br />NAILS 1 <br />5/8" � <br />THRU <br />BOLT <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN, EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing H ETAL20 INSTALLATION <br />&13/4" <br />Joist <br />n joists meet over wall, provide <br />minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />177. <br />• ■ • ...; • <br />6„ A 11Z" ROUND HOLE MAY -/ 6„ 6„ DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y2" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yz" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Yz" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB, THE JOIST MAY BE SET WITH THE i z" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAYBE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Joist hanger <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) —I I �J l 1-4, -LI-- 11— <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM <br />° v <br />SEE PLAN FOR °• a . • <br />FOUNDATION INFO 4 a <br />STEM FOUNDATION <br />GRADE <br />`ill\ Filler block. r <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be fight <br />to bottom of top flange with to top of bottom flange with <br />114%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiff ner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0,6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />REINF, SEE PLAN <br />/1vl4 l nM0r_ 4 rvV_ <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />JOA' <br />LOCATION OF <br />SECOND H10A <br />SIMPSON (WHEN <br />w/ (18)10d ° REQUIRED) <br />NAILS <br />UPLIFT =1 <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />r—PLUMBING LINE <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @PIPE <br />PENETRATION PLUMBING LINE <br />a <br />Q a °a. n av G <br />11 111-�1= I 1=) I I=I I C <br />-► I I-1 I —1 e' ' Q <br />,II_,,,,III v a e a e _ II <br />.. a IIti <br />.Q <br />SEE FND. PLN. <br />SIZE & REINF. <br />F �0 V <br />V <br />z_M <br />0 <br />z�z <br />Q <br />z <br />V) (D <br />w <br />� p <br />•O <br />w <br />T <br />Ln _ <br />viera <br />E <br />F- <br />U <br />CO <br />W <br />H <br />—' 8 <br />N M <br />Im M <br />m ,-1°0 M <br />_ <br />O o cV <br />o <br />< o <br />¢m <br />� o. o <br />u,g-v <br />�i ¢ o <br />B D. <br />®� <br />� - N <br />0 �`N <br />O p N � �i 00 <br />Z WIlIll- <br />45 <br />W <br />W �_ s a <br />� E� <br />Ck <br />Z 0o <br />C <br />C N rra <br />N Mpp <br />U)9bi <br />W �jtioN¢m <br />� <br />V ,,, I <br />�\� (U�j <br />.f. •✓ <br />sn <br />zz �° <br />4�O O�{c�t <br />" F i— <br />S`5'rQ",� <br />%FE <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and spermcations contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />z <br />rn <br />LU� <br />LU <br />za <br />Uu¢°d[r <br />Moo <br />z0ZxQ <br />U Zz <br />LU <br />o <br />A <br />uJ <br />L <br />w <br />z0 <br />rU <br />Ez <br />J w <br />_ <br />00 <br />f-- <br />. <br />N <br />o <br />J <br />ry <br />,6p <br />0� <br />U2: <br />N <br />�/� <br />V J <br />¢ Z <br />i� <br />C7<wCe <br />¢Ce <br />0 M <br />goo <br />z <br />Z <br />*-� <br />lu <br />� a 1 <br />J <br />W <br />lL1 <br />Z <br />If <br />¢ z o <br />"vU <br />S~8 <br />M <br />Q <br />�, <br />z <br />m <br />Ln <br />(� <br />Z <br />g <br />= <br />se <br />¢X <br />rn <br />T__I <br />n- <br />to <br />s <br />SCALE : AS NOTED <br />DATE : 7/29/2019 <br />TECH: SCASEY <br />VERSION N0. 10 <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.