<br />Re: Wood Construction Connector Compliance for 2015 International Codes & 2017 Florida Codes -- 0
<br />L }a Q
<br />To Whom It May Concern: - � O `/0 0-
<br />Section 2303.5 of the 2015 International Building Code (IBC) and 2017 Florida Building Code (FBC) specifies that -� v )
<br />joist hangers shall be tested per ASTM D7147 Testing and Establishing Loads of Joist Hangers. Previous versions of
<br />the IBC and FBC required testing to comply with ASTM D1761 Test Method for Mechanical Fasteners in Wood. Both
<br />methods determine a connector's allowable load as the lowest of the following:
<br />1. Lowest ultimate of three tests (or average of 6) with a safety factor of 3
<br />2. Average load at 1/8-Inch deflection
<br />3. Calculations per American Wood Council National Design Specification for Wood Construction (NDS
<br />The primary changes in ASTM D7147 are requirements to measure properties of the tested materials, such as steel
<br />strength, fastener strength, and wood specific gravity. The tested ultimate loads must be adjusted when tested
<br />material properties exceed the specified properties.
<br />ICC Evaluation Services (ICC-ES) revised AC13 Acceptance Criteria for Joist Hangers and Similar Devices in
<br />October 2016 to incorporate a methodology to evaluate products to the 2015 I -Codes. Simpson Strong -Tie is working
<br />on re-evaluating wood construction connector loads to the new standard to update our product evaluation reports to
<br />the 2015 ]-Codes. As soon as the updated evaluation reports are completed, we will apply for Florida Product
<br />Approvals
<br />However; reevaluating a large number of products will take time. While manufacturers work with product certification
<br />agencies to update their wood connector evaluation reports, we recommend that building departments under the
<br />2015 I -Codes and 2017 Florida Codes continue to accept code reports showing compliance to the 2012 and 2014
<br />editions, respectively, until July 2018.
<br />The information in this letter is valid until 61302018 when it will be re-evaluated by Simpson Strong -Tie. Please visit
<br />wyvw.strondtie.com for additional pertinent information. If you have questions or need further assistance regarding
<br />this matter, please contact the Simpson Strong -Tie Engineering Department at 800.999.5099.
<br />Sincerely,
<br />SIMPSON STRONG -TIE COMPANY INC.
<br />Keith Cullum, P.E., LEER AP dwfBDW
<br />Engineer, Southeast U.S. Branch
<br />Page I of I
<br />Simpson Strong�Tie Company Inc. 2221 Country Lana McKinney, TX 75069 Phone: 972.542.0326 Fax 972.542.4139 www.stronatie tom
<br />W
<br />Z
<br />co
<br />O
<br />a L
<br />O
<br />III
<br />O
<br />i
<br />V,
<br />IM
<br />U m
<br />O L
<br />w
<br />Q W
<br />z J
<br />z
<br />J
<br />SHEET N0.
<br />PA1.0
<br />n?'i cif« ;i._:.�,:.:.. _F .- .
<br />� � `� ���1�1 -��� k � �. -
<br />Y'
<br />� ,sg,v i'f
<br />y^"� t x��,5kzs".s, � 1
<br />F+£.: �n ,� �. :Y 31
<br />w t� [lSC(r `N_C' �
<br />fi-1x$IiH'� 7�'� �
<br />: �' �h� � T,'B.?���$tt'f•.� . � �
<br />r;.Y
<br />,.+
<br />$ '• ,4-
<br />..,.�
<br />� :C
<br />+';f
<br />5,,.
<br />+. 'v'Pl In ��. A. 't
<br />�:" � -�e�fCNaI�fA: �
<br />A3
<br />FL17244 1
<br />ESR-3455
<br />A23
<br />FL10448.2
<br />ESR-2606
<br />HD210-2
<br />FL17232.3
<br />ESR-3445
<br />HU210.2
<br />FL10856.4
<br />ESR-2549
<br />HD212-2
<br />FL17232.3
<br />ESR-3445
<br />HU212-2
<br />FL10856.4
<br />ESR-2549
<br />HD216
<br />FL17232.3
<br />ESR-3445
<br />HU216
<br />FL10856.5
<br />ESR-2549
<br />HD218.3
<br />FL17232.3
<br />ESR-3445
<br />HU216-3
<br />FL10858.1
<br />ESR-2549
<br />HD26
<br />FL17232.2
<br />ESR-3445
<br />HU26
<br />FL10856.3
<br />ESR-2549
<br />HD28-2
<br />FL17232.3
<br />ESR-3445
<br />NU28-2
<br />FL10856.4
<br />ESR-2549
<br />HD410
<br />FL17232.4
<br />ESR-3445
<br />HU410
<br />FL10856.9
<br />ESR-2549
<br />HD412
<br />FL17232.4
<br />ESR-3445
<br />HU412
<br />FL10856.9
<br />ESR-2549
<br />HD610
<br />FL17232.4
<br />ESR-3445
<br />HU610
<br />FL10656.10
<br />ESR-2549
<br />HD0410
<br />FL17241.7
<br />ESR-3444
<br />HUC0410
<br />FL11468.11
<br />SIM200804
<br />HGA10
<br />FL17699.1
<br />Evaluation Report
<br />HGAIOKT
<br />FL11470.4
<br />SIM200803
<br />HGAM10
<br />FL17699.1
<br />Evaluation Report
<br />HGAMIOKT
<br />FL11470.4
<br />SIM200803
<br />HHCP2
<br />FL17238.7
<br />ESR-3448
<br />HCP2
<br />FL10447.2
<br />ESR-2551
<br />HTA16
<br />FL17680.4
<br />Evaluation Report
<br />HETA16
<br />FL11473.5
<br />SIM200802
<br />HTA20.18
<br />FL17680.4
<br />Evaluation Report
<br />HETA20
<br />FL11473.5
<br />SIM200802
<br />HTT16
<br />FL17324.2
<br />Evaluation Report
<br />HTT16
<br />FL11496.1
<br />ES-0130
<br />HTT45
<br />FL17324.2
<br />Evaluation Report
<br />HTT22
<br />FL11496.1
<br />ES-0130
<br />HTW16
<br />FL17244.8
<br />ESR-3455
<br />HTS16
<br />FL10458.22
<br />ESR-2613
<br />HTW20
<br />FL17244.8
<br />ESR-3455
<br />HTS20
<br />FL10456.23
<br />ESR-2613
<br />HTW24
<br />FL17244.8
<br />ESR-3455
<br />H7S24
<br />FL10456.24
<br />ESR-2613
<br />HTW30
<br />FL17244.8
<br />ESR-3455
<br />HTS30
<br />FL10456.26
<br />ESR-2613
<br />HTWM16
<br />FL6223.2
<br />Evaluation Report
<br />HTSM16
<br />FL11473.11
<br />SIM200802
<br />HTWM20
<br />FL6223.2
<br />Evaluation Report
<br />HTSM20
<br />FL11473.11
<br />SIM200802
<br />HUGT2
<br />FL6223.3
<br />Evaluation Repo
<br />PRODUCT APPROVAL SPECIFICATION SHEET (2018) January 9, 2019
<br />As required by Florida Statute 553.842. and Florida Administrative Code 9B-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the
<br />construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed
<br />products.
<br />Category/Subcategory
<br />Manufacturer
<br />Product Description
<br />Approval Number(s)
<br />Test Pressures
<br />1. EXTERIOR DOORS
<br />A. SWINGING
<br />ThermaTru
<br />Firber-Classic and Smooth -Star (NON -IMPACT)
<br />FL20461.1
<br />+87.0/-67.0 psf
<br />ThermaTru
<br />Firber-Classic and Smooth -Star (NON -IMPACT)
<br />FL2D481.6
<br />+67.0/-67.0 psf
<br />ThermaTru
<br />FirberClassic and Smooth -Star (NON -IMPACT)
<br />FL20461.9
<br />+67.0/-67.0 psf
<br />ThermaTru
<br />Firber-Classic and Smooth -Star (NON -IMPACT)
<br />FL2pg61.14
<br />+67.0/-67.0 psf
<br />ThermaTru
<br />Classic -Craft and Benchmark
<br />FL15225.1
<br />+67A/-67.0 psf
<br />ThermaTru
<br />Smooth -Star and Benchmark
<br />FL15225.5
<br />+67.0/-67.0 psf
<br />ThermaTru
<br />FiberClassic, Smoothstar, ClassicCraft, Rustic
<br />FL7640.1
<br />+67.0/-67.0 psf
<br />B. SLIDING
<br />MI Windows and Doors
<br />Series 420
<br />FL15332.1 - FL15332.5
<br />+40.0/-40.0 psf
<br />PGT
<br />Series 5570
<br />FL251.10
<br />C. SECTIONAL
<br />Clopay Building Products
<br />Residential WindCode Doors W5 (8X7)
<br />FL15279.37
<br />+30.0/-32.0 psf
<br />Clopay Building Products
<br />Residential WindCode Doors W5 (16X7)
<br />FL15279.53
<br />+30.0/-30.0 psf
<br />Clopay Building Products
<br />Residential WindCode Doors W6 (SX7)
<br />FL15279.85
<br />+36.0/-42.0 psF
<br />Clopay Building Products
<br />Residential WindCode Doors W6 (16X7)
<br />FL15279.102
<br />+37.0l-41.0 psf
<br />D. METAL LOUVERED DRS
<br />Curries Division of AADG, Inc
<br />807,707,727,747,and 847 Single &Pairs of Doors
<br />FL11537.1
<br />N/A (see lost sht)
<br />2. WINDOWS
<br />A. SINGLE HUNG
<br />MI Windows and Doors
<br />Series 185
<br />FL17499.2
<br />+50.0/-55.Opsf
<br />PGT
<br />Series 5500
<br />FL239.7
<br />B. HORIZONTAL SLIDER
<br />MI Windows and Doors
<br />Series 188
<br />FL15351.1
<br />+4D.0/-50.0 psf
<br />C. FIXED
<br />MI Windows and Doors
<br />Series 185
<br />FL15349.1
<br />+40.0/-40.0 psf
<br />PGT
<br />Series 5520
<br />FL243.9
<br />D. MULLION
<br />MI Windows and Doors
<br />Series 5784
<br />FL15353.2
<br />N/A
<br />PGT
<br />Series 5500
<br />FL261.1
<br />N/A
<br />E. OTHER
<br />3. PANEL WALL
<br />A. SIDING
<br />James Hardie Building Prod.
<br />Cemplank Lap Siding and HardiePlank Lap Siding
<br />FL13192.1 - FL13192.2
<br />N/A
<br />B. SOFFITS
<br />Alside
<br />Solid and Vented Soffit
<br />FL15272.1 - FL15272.2
<br />+70.0l-70.0 psf
<br />C. OTHER
<br />4. ROOFING PRODUCTS
<br />A. ASPHALT SHINGLES
<br />GAF
<br />3 Tab, Dimensional
<br />FL10124.1
<br />N/A
<br />B. UNDERLAYMENTS
<br />Tamko
<br />151b Felt Underlayment
<br />FL12328.6
<br />N/A
<br />C. ROOFING FASTENERS
<br />NOT USED
<br />D. ROOF VENTILATORS
<br />Thompson Arch Metal Comp.
<br />Off Ridge Vents
<br />FL16918.1 - FL16918.4
<br />N/A
<br />Florida Metal Products, Inc
<br />Vent RV10
<br />FL21580.3
<br />N/A
<br />Lomanco, Inc
<br />DA-4 Exahust Vent
<br />FL17202.1
<br />N/A
<br />E. ROOFING TILES
<br />Boral Tile
<br />Villa 900
<br />FL7849.27 - FL7849.28
<br />N/A
<br />Boral Tile
<br />Saxony 900
<br />FL7849.16 - FL7849.20
<br />N/A
<br />F. METAL ROOF
<br />Gulf Coast Supply &Manufacturing, LLC
<br />0.032" Aluminum GulfLok 16" wide roof panel
<br />FL11651.2 R3
<br />N/A
<br />5. SHUTTERS
<br />A. STORM PANELS
<br />Global Protection Products
<br />Galvanized Steel Storm Panels
<br />FL15076.1 - FL15078.2
<br />N/A
<br />All American Shutters &Glass
<br />Galvanized Steel Storm Panels
<br />FLt7869.1
<br />N/A
<br />6. STRUCTURAL
<br />COMPONENTS
<br />A. WOOD CONNECTORS/
<br />USP Structural Conn.
<br />see chart
<br />ANCHORS
<br />Simpson Strong -Tie
<br />see chart
<br />B. TRUSS PLATES
<br />ITW Building Components
<br />Alpine Truss Plates
<br />FL1999.1 - FL1999.4
<br />N/A
<br />MiTek Industries, Inc.
<br />Truss Plates
<br />FL2197.1 - FL2197.5
<br />N/A
<br />C. ENGINEERED LUMBER
<br />Weyerhaeuser
<br />Rim Board, LVL, PSL, LSL
<br />FL6527.1 - FL6527.5
<br />N/A
<br />D. MATERIAL
<br />Cast -Crete Corp.
<br />High Strength Concrete Lintels
<br />FL158.1
<br />N/A
<br />Commercial Concrete Products, Inc.
<br />High Strength Concrete Lintels
<br />FL1774
<br />N/A
<br />The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the
<br />jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I
<br />understand these products may have to be removed if approval cannot he demonstrated during inspection.
<br />APPLICANT SIGNATURE
<br />DATE
<br />11 ,II �,. IBkiir-Ili-.:. i,._]I,. LJ"L�,i . ALA ..II. 1;.:I �II diF:al
<br />
|