My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3287 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3287 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 3:14:59 PM
Creation date
2/28/2025 11:06:40 AM
Metadata
Fields
Template:
Building Plans
Street #
3287
Location
Lytton Hall Dr
Contractor
Lennar Home
Building Plans - Permit #
21902
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />n <br />200 amp <br />150 amp <br />POWER CO. FEED----_ <br />INTERSYSTEM <br />BONDING TERMINATION PER : <br />NEC 14, 250.94---/// <br />NEMA1 <br />200 AMP <br />copper to lights & outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />� 4 Bare Cu Ground <br />#4 GROUNDING WIRE <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFf <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />Cb <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />;W <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />FD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />QQ <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />►� <br />ELECTRIC METER <br />n_ <br />ELECTRIC PANEL <br />—L...I <br />DISCONNECT SWITCH <br />��9 <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />L <br />OWNER'S S Y ITE <br />1 ' <br />/ ROUGH -IN FOR / <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />u <br />Y <br />PA I�O �� j CAFE <br />FAMILY RM <br />G � <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />GFI <br />L0U <br />U.C. OUTLET <br />FOR DW <br />U.C. OUTLET <br />iil . n <br />_ _i ■ IlGr Jam, ■li � V 1f��1 <br />�I /PENDANT <br />PER SPECS <br />7M.1 <br />i 111 ' <br />H.B. <br />GFI DISC. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H, <br />IRRIGATION _ _ _ _ <br />---------'—� VERIFY LOCATION <br />GFI @ 44" A.F.F. <br />W H ELECTRICAL PANEL I I <br />1 0 II <br />W.I.C. I <br />I I I I <br />I <br />2 CAR GARAGE <br />I I I I <br />GFI FOR 1 I I <br />GAR. DOOM I I <br />1 GFI I I <br />GFI @ 44" I I <br />A.F.F. I I <br />I I I I I <br />-----------J <br />I A I I <br />N� I �( 1 1� <br />OPT. OPT. <br />o <br />D. <br />r \ / <br />AHU I GFI @ 44" <br />A.F.F. <br />CH <br />I <br />_ 1 ENTRY <br />WP <br />'3 111111111111111 <br />GFI <br />--------------- <br />h S.D. -� S.D, <br />C.M <br />I <br />OPT. <br />RE_ - iBEDROOM 2 �� , / 1 S.D. IF <br />BEDROOM 311ATBEDROOM 4 <br />G' I /� / N I t \ � 12ROUGH-IN FOR <br />OUCH -IN FOR �/ ' '/ ` \ OPT. CLG. FAN/ <br />I OPT. CLG. FAN/ / / I I LIGHT PRE -WIRE <br />LIGHT PRE -WIRED G I O \ �/ <br />I <br />ROUGH -IN FOR I <br />OPT. CLG. FAN/ I <br />LIGHT PRE -WIRE <br />4-4 <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />l <br />L r u <br />0 <br />Z N O <br />a <br />z � <br />Q o <br />M <br />z <br />(n a <br />n' `o <br />Q) LL <br />a--+ <br />r6 r.tJ <br />a r1 <br />'U a <br />tU <br />0 w <br />o <br />� � <br />c.) m <br />w � <br />o g <br />(� N <br />0 <br />Of <br />`[ ° 0 <br />Sm <br />N N <br />v�i N <br />Z LU o <br />o w Z <br />Z <br />W Nz <br />Wm� w <br />V 4 <br />Z 0 <br />. Ito N O <br />LLC <br />W Q �4O M�= o <br />U U H <br />00 <br />rn <br />0 <br />CV <br />M <br />ti <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />r, <br />CD <br />CDJ <br />Z <br />co <br />coO <br />J <br />n <br />Z <br />¢ <br />� <br />Q E <br />n <br />=o <br />�� <br />» <br />Zo <br />z® <br />oa <br />X O <br />0o¢ <br />0 U <br />U <br />00< <br />CD E <br />CD <br />CV <br />ao <br />¢ z <br />0 <br />ao <br />�z <br />w z <br />r � <br />w0 <br />� <br />rp <br />j CY <br />C <br />z <br />�m <br />'0 <br />0� <br />>z <br />M z <br />Q � <br />�� <br />a 0 <br />U <br />a <br />(nw <br />C) <br />�3 <br />O <br />a� <br />J <br />ui <br />� o <br />CDa <br />cfl <br />� <br />-0'- i <br />z¢ <br />0 — <br />U3 <br />C C:)C <br />> <br />L <br />\W <br />/ <br />Q0 <br />M <br />oo--% <br />> <br />T <br />0 <br />U <br />CL <br />m <br />z' <br />C <br />o <br />r1^ <br />O <br />Y, <br />T- <br />I � <br />,- <br />ui <br />w M M N <br />a <br />m <br />� T N I <br />Z <br />Z <br />E O N <br />E <br />c <br />a <br />U _j Q p <br />JOB <br />NO: 19-5335 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />