My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3302 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3302 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 3:29:41 PM
Creation date
2/28/2025 11:06:55 AM
Metadata
Fields
Template:
Building Plans
Street #
3302
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
21894
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• n r U <br />SIMPSON HGAM11 <br />W/ <br />(4)1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & ( <br />1/4"x2 3/4" <br />TITEN TO CMU <br />SEE STRUCTURAL NOTES AND BACKNAIL W/ (2)16d NAILS BACKNAIL w/ (2)16d NAILS SIMPSON H1 OA w/ (18) SIMPSON SP4 w/ 6 1 <br />TOENAIL W/ (2) 16d NAILS SIMPSON H10A w/ (18) () Od x <br />NAILING SCHEDULE FOR 2"x4" 1 Od x 1 12" AT EA. <br />SHEATHING DETAIL 2"x4" OUTLOOKER SEE STRUCTURAL NOTES AND 1 Od x 1 12" AT EA. SEE STRUCTURAL NOTES OUTLOOKER 1 12 AT EA STUD (USE BACKNAIL w/ (2) 16d NAILS SIMPSON H10A w/ (18) <br />OUTLOOKER SP6 FOR 2x6 WALL USE 10d 1 12" AT EA <br />TOP CHORD @ 24" O.C. <br />BLOCKING FOR <br />FIRST FOUR <br />NAILING SCHEDULE FOR OUTLOOKER <br />SHEATHING DETAIL <br />AND NAILING SCHEDULE <br />24" O.C. <br />@ OR SHEATHING <br />DETAIL <br />TOP CORD BLOCKING <br />ROWS OF 45° ± 24" MAX. <br />TOP CORD BLOCKING 45°± <br />2X4 CONT"L" BRACE <br />TRUSSES @ SIMPSON H1 OA w/ (18) <br />FOR FIRST FOUR <br />FASTENED W/ (2)10d 3" <br />FOR FIRST FOUR ROWS <br />EDGES OF 2x4 CRO BRACE 10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24" 0/C. CMID HEIGHT <br />OF TRUSSES @ EDGES <br />SHEATHING APPROX. 8" FROM OUTLOOKER <br />EDGES OF <br />OF SHEATHING TYPICAL <br />TYPICAL @ RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />SHEATHING TYP. 2X4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />48" O.C. EACH JOINT W/ (3) 10d <br />@ 8'-0" O/C. <br />EXTEND AT LEAST 90% OF <br />AT LEAST 90% OF WEB <br />MAX. & (2)10d TOE NAILS @ <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />" <br />LENGTH (SEE TABLE) <br />EA. END @ 48" O.C. <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE ) <br />i <br />2x6 P.T. GABLE TRUSS <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />SILL 1/2"CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROM LEDGER TO <br />' <br />7/16" OSB SHEATHING <br />& (2)10d TOE NAILS @ <br />BLOCKING <br />ATTACHED W/ 10d <br />EA. END <br />NAILS 6" O.C. EDGES <br />@ <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />10dX3" @ 3" 0/C <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />1/2" CDX PLYWOOD OR 7/16" <br />ATTACHED <br />SNAILS <br />THROUGH CHORD <br />CORD ATTACHED W/ (2)16d TOENAILS <br />6 <br />1 NAILS 6" O.C. <br />INTO 2"x6" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />w/ @ <br />w/ GE <br />EDGES AND 12" O.C. FIELD <br />2x4 PANEL BLOCKING @ <br />2x4 7' ON TOP OF PANEL BLOCKING, <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />O.C. FOR THE FIRST (4) <br />FASTEN WITH 10dx3" @ 4" O/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />NOTCH "L" BRACE HERE <br />ROWS OF TRUSSES FRO <br />@ 48" O.C. <br />5/8" x 10" "J" BOLT @ 48" O.C. <br />WEEP SCREED <br />EA. END TYP. TOP & <br />MOISTURE BARRIER <br />BOTTOM ATTACHED w/ <br />5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM <br />SIMPSON HETA20 w/ (8)1Odxl 1/2" NAILS AT 6'-0" <br />INSTALLED PER MANUF. <br />16d TOENAILS <br />PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />1Odxl 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7)1Od NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4) 1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTIONEMBEDMENT <br />O.C. MAX) T MIN. 4" <br />IN KO BLOCK <br />ri <br />GABLE WEBSECTION <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />10d NAILS & (4)1/4"x21/4" SCALE: N.T.S. <br />S5 <br />SCALE: N.T.S. <br />Srj <br />TITEN ON OUTSIDE <br />SIMPSON H10A w/ (18) <br />BACKNAIL W/ 2 16d NAILS <br />SP8 FOR 2x8 WALL) <br />2) <br />SEE STRUCTURAL NOTES OUTLOOKER <br />AND NAILING SCHEDULE <br />2x4 OUTLOOKER <br />FOR SHEATHIN <br />DETAIL <br />@ 24" O/C <br />2x4 OUTLOOKER @ 24° <br />TOP CORD <br />4" MAX. <br />O.C. (OPTIONAL - SEE <br />BLOCKING FOR <br />ELEVATIONS) <br />FIRST FOUR ROWS <br />DOUBLE TOP PLATE <br />OF TRUSSES @ <br />2x4 CROSS BRACE APPROX. 8" <br />2"x4"CROSS BRACE <br />24" MAX. <br />EDGES OF <br />FROM RIDGE FASTENED AT <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />EACH JOINT W/ (2)1Od & (2)1Od <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />TOE NAILS @ EA. END <br />EACH JOINT W/ (2) <br />AT LEAST 90% OF WEB <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE &SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />7/16" OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />NAI <br />NAILS <br />ATTACHED w/ 10d NAILS <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />@ 6" O.C. EDGES AND 12" <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />O.C. FIELD <br />(2) 16d NAILS <br />BOTTOM ATTACHED <br />48 <br />2x BLOCKING <br />W/ (2)16d TOENAILS <br />2x4 "T" ON TOP OF PANEL <br />k2x4'7" <br />BLOCKING, FASTEN WITH <br />M <br />ON TOP OF PANEL <br />SIMPSON HGAIOKT w/ (4) 1/4"x1 1/2" <br />1Odx3" @ 4" O/C <br />BLOCKING, FASTEN WITH <br />SDS SCREWS TO TRUSS & (4)1/4"x3" <br />10dx3" @ 4" O/C <br />SDS SCREWS TO PLATES AT 36" O.C. <br />SIMPSON SP2 w/ (12)10d <br />2x4 LEDGER (MATCH BOTTOM <br />NAILS AT EACH STUD <br />DBL. TOP PLATE <br />CHORD SLOPE OF ADJACENT <br />TRUSS) STUD WALL (SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. SS SCALE: N.T.S. SS <br />() <br />1 Od x 1 12" AT EA. 2x4 OUTLOOKER <br />REFER TO DETAIL J <br />N <br />SEE STRUCTURAL <br />OUTLOOKER F@ 24" O/C <br />ON SHEET S5 FOR <br />NOTES AND NAILING <br />TOP CORD <br />X-BRACING, AND TOP <br />N <br />SCHEDULE FOR <br />BLOCKING FOR <br />CHORD BLOCKING <br />`� <br />;000 <br />SHEATHING DETAIL <br />FIRST FOUR ROWS <br />INFORMATION <br />OF TRUSSES @ <br />1 <br />1 <br />1/ „. <br />2"x4" CROSS BRACE <br />24" MAX. <br />EDGES OF <br />WOOD TRUSSES <br />�° <br />00 <br />00 <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />•2x4 RAT RUN BRACING <br />" <br />EACH JOINT W/ (2) <br />AT LEAST 90% o OF WEB <br />AT 24 O.C. ON TOP OF <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />BOTT. CHORD FOR 4 <br />NAILS @ EA. END <br />GABLE TRUSS <br />TRUSS SPANS <br />ATTACHED W/ 2 -16d <br />`jur <br />2x4 PANEL BLOCKING <br />1/2"CDX PLYWOOD OR 7/16" <br />AT EA. TRUSS JOINT <br />(2) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 6" LAMINATIONS W/ (2) ROWS OF <br />@ 48" O/C FOR THE <br />FIRST (4) ROWS OF <br />(2)16d NAILS <br />OSB SHEATHING ATTACHED <br />W/ 10d NAILS @ 6" O.C. <br />OF STAGGERED 10d COMMON WIRE NAILS <br />OF STAGGERED 30d COMMON WIRE NAILS <br />STAGGERED 30d COMMON WIRE NAILS <br />TRUSSES FROM EA. <br />E <br />ES AND 12" O.C. FIELD <br />2x4 BLOCKING @ 24" <br />(D = 0.148", L = 3") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />END TYP. TOP & <br />JACK TRUSS <br />O/C w/ (2)16d <br />TOENAILS @ EA. END <br />NOTES: <br />BOTTOM ATTACHED <br />SEE PLAN FOR <br />1 ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY PROVIDE 1/4" DIA x 51/2" LAG SCREWS OR EQUAL <br />w/ (2)16d TOENAILS <br />CONNECTION <br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) Em <br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL OF PANEL <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) 2x4 TOP <br />BLOCKINNG, FASTEN WITH 2x4 BLOCKING W/ _ .. <br />3) EACH 30d COMMON NAIL MAYBE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION 10dx3" @ 4" 0/C (2) 12d TOENAILS <br />EXT. WALL CONN. COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />NON - LOAD BEARI G LOCATION D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION K'9 <br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 <br />ADDITIONAL INFORMATION. <br />2"x4" OUTLOOKER @ 24" - <br />O.C. W/ (2)10d PER JOINT <br />IINIMUM 2x <br />;ROSS BRACING <br />3EE PLAN FOR <br />OCATIONS) 10dx3" O/C 2"x4 <br />TOENAIL 6" O/C RUN <br />W/ (2)16d TYPICAL <br />(2)16d PER NAILS <br />JOINT <br />L CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />CROSS BRACING DETAIL rj_"� <br />SCALE: N.T.S. S5 <br />ALTERNATE NON -DROP <br />GABLE END DETAIL <br />SCALE: N.T.S. <br />1 GABLE TRUSS <br />"L" BRACE W/ 1 Od @ 4" O.C. <br />12 (SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />6.9 MAX. <br />5 <br />S5 <br />6 <br />S5 <br />It 11 <br />ill• <br />�I <br />\- <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />SCALE: N.T.S. <br />PRE-ENGINEERE <br />WOOD TRUSSES <br />S5 SCALE: N.T.S. S5 <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />`MINIMUM (2)16d PER JOINT MINIMUM 2x4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)10d <br />WOOD TRUSSES TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />0 <br />z <br />w <br />J-1 \—BRACING w/ (3)1 Od x 3" AT <br />• EACH CONN. @ 24" O/C <br />SIMPSON HGAMIOKTA w/ (4) MOISTURE BARRIER <br />1/4"xl 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"x2 3/4" BOND BEAM <br />TITEN TO CMU <br />MASONRY WALL <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB J <br />SINGLE "L" BRACING DETAIL s <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE -� <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE 7 <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 CONTINUOUS BOTTOM CHORD BRACING 2X4 MIN. <br />M <br />1111111 <br />rr <br />ARCHITECTURAL FINISH NOTE: <br />EXT. WALL CONN. NON -LOAD <br />BEARING LOCATIO(UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - T-O" <br />T-0" - 6'-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"xi 1/2" SDS <br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS <br />TO PLATES (TYP.) <br />r-GABLE TRUSS <br />1-CONT. BEARING <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />Uj <br />0� <br />Cr <br />CORNER JACK <br />C <br />Y <br />11 <br />U <br />cr <br />w <br />z <br />O <br />U <br />HIP FRAMING REFERENCE PLAN <br />E <br />S5 <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 <br />SCISSOR TRUSS <br />LTOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)1 Od AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />0 <br />a <br />CO <br />0 <br />i <br />z_ M � <br />N M <br />z g <br />Q= <br />J M <br />� N <br />Z0 <br />v,l <br />a)T <br />W Y <br />L LL, <br />o Q <br />00 <br />N c <br />�2r— <br />o <br />U C° <br />mrn <br />� 2E <br />i w <br />Q <br />�Q <br />so <br />N N <br />I <br />o� I <br />yy oN � z <br />Z W � <br />J II W W <br />= Q <br />QN LL" c y it <br />LULU > � <br />� a g; :9 <br />L <br />Z .syora� o 0 <br />a <br />N�1�111!ll,l <br />ZLIL <br />LU <br />ZZ- <br />- —� 0 <br />; <br />...••. <br />kOFESS1O <br />�� <br />\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />co <br />o <br />W <br />Q <br />U_ <br />E Q <br />I✓ CJ <br />z o <br />�0 <br />¢ 6 <br />� <br />» <br />Z® <br />w <br />I_ <br />x� <br />0o <br />zof <br />o <br />N <br />az�z <br /><= <br />o <br />�Z2z <br />ww <br />¢� <br />m0 <br />z <br />N c <br />Q� <br />pY <br />U <br />hm <br />OLL <br />Z <br />Q W <br />c22 J <br />N <br />a°„ <br />oa <br />w� <br />zz <br />aO <br />.'z'a <br />W <br />3 <br />�G <br />o <br />CD. <br />Wz <br />< <br /><a <br />ti� <br />= <br />moo' <br />aF <br />�1 <br />oa <br />za <br />O <br />o3 <br />C O CD <br />L <br />W <br />,!00 <br />M <br />oo-*.% <br />I.L (D <br />N <br />0 <br />.2! <br />^ L <br />L <br />N <br />nQ <br />li <br />m <br />1 <br />� <br />2 <br />r0) <br />c <br />� <br />�--• <br />O <br />LO <br />r <br />� � <br />cN <br />r <br />ai <br />z <br />N "i n <br />o <br />z <br />C <br />O H <br />E .d <br />a. <br />C <br />a <br />U Q p <br />JOB NO : 19-5339 <br />SCALE : AS NOTED <br />SHEET NO. <br />S5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.