Laserfiche WebLink
O A O <br />H.B. S3 <br />EGRESS EGRESS <br />20,_6s„ <br />-- x -- . O <br />r T <br />-- N <br />PAWY <br />16"EWP n <br />�Iw <br />�� <br />�s8 <br />2'- - <br />10'-4" <br />4° <br />10,-44„ <br />m <br />00 <br />2,4" <br />j <br />i <br />I <br />I � <br />FIBERGLASS <br />SURROUND <br />I <br />c2 <br />v <br />AC PAD \ <br />\ <br />I a <br />°° <br />S3 <br />TYP @ 1 <br />STORY _ <br />RANGE: <br />Cq <br />13 <br />5'- <br />2„ <br />ct <br />`� <br />oVAI <br />OE C7 I <br />rri <br />°° CAFE <br />� <br />LO 8'-0" CLG. <br />PATIO CARPET <br />o <br />N O <br />N w <br />� <br />¢ <br />> <br />J <br />U <br />]III <br />I <br />I <br />! . <br />OPT. <br />REF. I <br />BEDROOM <br />8'-0"CLG. <br />CARPET <br />- <br />BEDROOM 3 <br />8 -0 CLG. <br />2 ' " <br />CARPET <br />I <br />IV"I <br />ti <br />00 c=no W <br />N O€F z <br />�) <br />b <br />r <br />BEDROOM 4 <br />I � ., <br />8 -0 CLG. <br />CARPET <br />I <br />=rn <br />6M O <br />6 <br />w <br />`"" <br />o <br />; <br />- <br />T <br />TI <br />ESI Kw/ <br />ISP <br />l��o <br />,_ <br />„ <br />ILE <br />Q o <br />���,////// <br />�- - � <br />I D.W. � o o � <br />� - - - <br />C--=-C-------� <br />o <br />-' <br />-- <br />------ <br />J+ <br />I <br />5' 4 <br />4'-0" 11-7 1 <br />5068 B.F. <br />8'-8" <br />5'-4" <br />14'-6" <br />4068 B.F. <br />7'-6" <br />iv <br />4'-7" <br />_ <br />R&S <br />o <br />2668 <br />2668 <br />� <br />IA00 <br />r <br />� <br />N <br />in <br />------------ <br />R&S <br />-------_ <br />HDR AT 7'-4" <br />I <br />23'_01„ <br />T-10" 7'-8" 10'-10$" <br />6" <br />I <br />„ <br />I <br />I <br />A <br />O <br />I <br />ENTRY <br />�' <br />O M <br />N <br />A <br />S3 <br />TYP @ 1 STORY <br />- & <br />FAMILY R M <br />I 9'-4" CLG. <br />I CARPET <br />4'-0 <br />9'�' C 3068 <br />CC D <br />S3 S3 <br />NOTE: fthISHED I <br />I WALLS TO BE I <br />I FLUSH. VERIFY IN i <br />FIELD. I <br />10 I <br />I I <br />i <br />8'-0" CLG. <br />Lo <br />o <br />2:12 VAULTED CLG. <br />I <br />5'.4 <br />R.A.G. <br />AHU <br />(4) 2x4 #2 SYP- <br />STUDS W/USP <br />S3 HTT4 @ BASE <br />IIN U will <br />I,x rW,1 <br />I it Q I <br />i <br />- <br />00 <br />I <br />I <br />I <br />I <br />I <br />I <br />8'- <br />„ C <br />• <br />G. <br />TILE <br />OPT.D <br />a <br />PT� <br />- <br />- - <br />c G <br />/7 <br />N S3 <br />I <br />17'-O$" <br />T <br />S <br />D <br />60"x36" <br />SHOWER <br />ell <br />1 1 f l <br />�� <br />K`� <br />EDGE OF SLAB 2" <br />BEYOND WALL <br />Ll� <br />20,_„ <br />I I <br />I I g l <br />I o l <br />I I <br />1 w 1 <br />I <br />I w I <br />I I <br />I X L7 <br />i <br />I <br />l <br />l <br />I <br />1 <br />I <br />I <br />I <br />I <br />(4) 2x4 #2 SYP STUDS <br />W/ US P HTT4 @ BASE <br />ERG <br />SURROU <br />R&S <br />------- <br />HANSON <br />BOX @ 36" <br />A.F.F. <br />DRYER VENT <br />THRU ROOF <br />2668 7, 8" <br />- -� <br />I <br />o <br />I <br />I <br />I <br />I <br />21368 <br />5'- <br />" <br />8' <br />3 <br />10�� <br />-1 <br />3'-0" <br />rn <br />OCnw <br />A M� I <br />w ' <br />I <br />OWNER'S SUITE <br />8'-0" CLG. <br />CARPET <br />�� <br />'' <br />W.I.C. <br />8'-0" CLG. <br />CARPET <br />I �, <br />I <br />I <br />2 CAR GARAGE <br />8'-0" CLG. <br />2'-6" BUILDER TO <br />PROVIDE <br />I I I <br />I I <br />I I I <br />I I <br />I <br />I <br />I <br />I <br />=�jl <br />a <br />00 <br />TIE <br />O APPLIANCE <br />I I <br />I <br />5-SH -- <br />r <br />I <br />J <br />PROTECTION <br />CO WHEN REQUIRED <br />N PER FBC <br />( I <br />T----------- <br />I <br />0 <br />0 <br />---_____ -- <br />R&S <br />go <br />T <br />v <br />s <br />H.B.T <br />HEADER SCHEDULE <br />SIZE <br />REMARKS <br />KHEADER <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) -1 3/4" X 71/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 } X 25 <br />S.H. <br />13 <br />20 X 38 j <br />18 } X 371 <br />S.H. <br />14 <br />20 X 501 <br />184 X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 62 j <br />S.H. <br />16 <br />20X72 <br />184X71 j <br />S.H. <br />11-12 <br />271/4X26 <br />26X25 <br />S.H. <br />11-13 <br />271/4X381 <br />26x371 <br />S.H. <br />11144 <br />27 4 X 50 j <br />26 x 50 <br />S.H. <br />11-15 <br />274X63 <br />26X621/2 <br />S.H. <br />11-16 <br />27 X72 <br />26X711/2 <br />S.H. <br />22 <br />37 X26 <br />36jX251/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 1 <br />36 } X 50 <br />S.H. <br />25 <br />37 j X 63 <br />36 4 X 621 /2 <br />S.H. <br />26 <br />37 J X 72 <br />36 4 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 } WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 <br />S.H. <br />33 <br />54 X 38 <br />52 } X 37 <br />S.H. <br />34 <br />54 X 50 <br />52 4 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 j X 624 <br />S.H. <br />36 <br />54 X 72 <br />52 j X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic , crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />C.A <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />OE <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />�G <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />111111111111111111 <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A1" <br />1ST FLOOR LIVING AREA 1936 <br />LIVING TOTAL 1936 <br />GARAGE 416 <br />FRONT ENTRY 20 <br />TOTAL AREA 2372 <br />INSULATION REQ. <br />LOCATION I R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />FIRST <br />FLOOR <br />PLAN <br />A � <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />1/ I GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />SCALE: Y4 r=1 '-On (GARAGE / LIVING) <br />0 0 <br />0 <br />0 <br />z N <br />z <br />� N <br />tJ1 z <br />� Ur <br />U � <br />- <br />O <br />U m <br />rn <br />2 g <br />Q <br />Om- <br />z W AN: 2XV <br />LU <br />%j <br />p14r317 <br />„. <br />LLI ff' . & <br />:0 <br />��•'• 0Q',• Nr <br />��si�JJlJQRO F•. SS\o <br />To the best of the Engineer's knowledge, info"naton and belief, <br />the structural plans and specttications contained witirin these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o <br />CD <br />o <br />w <br />z <br />ce E <br />z� <br />o <br />» <br />�� <br />Q <br />o. <br />E U <br />co <br />° <br />XU <br />z® <br />oa <br />So <br />�U <br />Z <br />O <br />O <br />N <br />I'- <br />a <br />Q0 <br />¢ <br />� �d <br />wz <br />¢ � <br />Wm <br />L <br />`Ux <br />6 = <br />NO <br />O <br />ZQ <br />z <br />o <br />QW <br />U <br />W <br />c� 3 <br />uLL <br /><o <br />a <br />nw <br />�G <br />_ <br />.9 <br />� 3 <br />W <br />0 <br />IIIJ <br />o <br />v <br />� <br />=1< <br />>� <br />c C:)0 <br />La <br />> d. <br />^L <br />W <br />i <br />M <br />00 <br />CN <br />> <br />O <br />C U <br />CN <br />n� <br />A <br />_ <br />it <br />T <br />c <br />•}� O <br />V <br />0*)_ <br />d' <br />T <br />I CM o 04 <br />V) <br />�-- <br />r <br />E <br />00 M <br />M N <br />0 <br />c <br />:3z N <br />E O <br />a <br />E <br />v _j ¢ o <br />JOB <br />NO : 19-5339 <br />SCALE : AS NOTED <br />SHEET NO. <br />1.0 <br />