ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />vvP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />0 <br />EXHAUST FAN <br />` <br />twt <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />i9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />I�U'i7�3K•atlx�� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />01 s14 copper to lights & outlets <br />NEMA <br />00 AMP t <br />200 A00 p12 copper to 20 amp clds <br />11 tl10-2 copper to WH <br />R10.3 copper to Dryer <br />METER <br />M71 N T <br />0 or 4/0 SER Alu <br />200 amp <br />150 amp IT <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP DISC. <br />GFI H.B. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn omn cmmrl <br />PUSH BUTTON SWITCH - DOOR BELL <br />i <br />SD <br />SMOKE DETECTOR <br />I <br />I <br />0 <br />CO <br />CARBON MONOXIDE DETECTOR <br />f <br />jIll <br />ji <br />I <br />W H VERIFY LOCATION <br />----- -----J <br />ELECTRICAL PANEL <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />RECEPT. <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />FOR ALARM VERIFY METER <br />SYSTEM LOCATION WITH <br />TELEVISION (OPTIONAL) <br />BUILDER <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />g <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />89 <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />O <br />0 <br />0 <br />z N t0 <br />zCD <br />Q <br />— M <br />) z <br />X <br />VJ Y <br />0 <br />0_'V)"' <br />ec <br />N <br />2 <br />U co <br />® ty iA <br />~ O $ <br />U o <br />• <br />or <br />48— <br />S2 <br />w <br />z <br />— <br />a A <br />R <br />�LU <br />Z <br />N <br />Z ti <br />N <br />W <br />[— <br />❑ ❑ <br />a� <br />0 <br />N <br />fM <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />CID o <br />CI),z <br />a <br />W <br />Q <br />a E <br />Wo <br />$R <br />a <br />(O ni <br />H r0 <br />— <br />f0 <br />x� <br />a� <br />VO <br />gU <br />Z <br />0 <br />O <br />N <br />L <br />$ <br />4+ <br />M <br />o <br />- <br />< <br />.0 <br />O� <br />Z <br />Q) <br />m <br />a° <br />aw <br />Fz <br />a <br />W <br />+Z <br />U�0 <br />w <br />LL <br />IIIIIIIII' <br />O <br />CCC) <br />< <br />"'� <br />0: 0 <br />0 <br />a = <br />�Z <br />zlc <br />o3 <br />C O <br />0 <br />AL1 <br />W <br />i <br />. tt� <br />M <br />N <br />,.1 <br />LtL <br />> <br />O <br />0 o <br />N <br />m <br />r <br />7 O � <br />T^ <br />11- <br />T O <br />L <br />r <br />I M o � <br />'- <br />E <br />ch <br />00 M N <br />z° <br />Z <br />E <br />B <br />c <br />a. <br />U Q p <br />JOB <br />NO: 19-5339 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />