My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3323 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3323 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 3:40:46 PM
Creation date
2/28/2025 11:07:05 AM
Metadata
Fields
Template:
Building Plans
Street #
3323
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
21908
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(2) 2x6 OR (2) 2x8 <br />/—PLAN <br />TOP PLATE SEE <br />1/2" MINIMUM CEMENT FINISH <br />(2) 2x HEADER TO SIT <br />2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE STANDARD 3" DIA. TEE <br />SEE PLAN FOR HEADER SEE PLAN FOR SIZE THREADED 3" DIA. EXTENSION - <br />CONNECTION SCREW OFF CAP (3" DIA.)—� <br />I DOUBLE 2x TOP <br />{ PLATE <br />I <br />2x DEAD WOOD @ MID FOR CLEAN -OUT <br />POINT w/ (3)12d MIN. EXTENSION FROM <br />TONEAILS SPACED EXTERIOR FACE OF BLOCK <br />EVENLY W LL S 1 1/2" MAXIMUM <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1 /2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />A 1 INTERIOR <br />HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL <br />FACE OF BLOCK WALL IS 21/4" <br />2x BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />VARIES 2x BOTTOM PLATE W/ (1)10d @ 8" <br />O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL 1 <br />SCALE: N.T.S. S4 <br />12 SEE TYPICAL WALL SECTION <br />(Np) SEE ELEV. PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2X4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12)10d (3)10d TOENAILS T&B <br />NAILS AT EACH STUD AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />STUD W/ (3)10d NAILS <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2) 16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" 0/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10)10d <br />NAILS AT EACH STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90" HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERAL NOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />BLOCKING (TYP.) <br />-ROOF TRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE`. N.T.S. <br />-SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />TO DRAIN <br />EXTERIOR <br />WALL CLEAN -OUT WALL <br />A <br />SCALE: N.T.S. 54 <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />1 ST COARSE 2ND COARSE 3RD COARSE <br />REFER TO WINDOW PRODUCT APPROVAL MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE <br />SHEETS FOR INSTALLATION INFORMATION BY COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE <br />MANUFACTURER. WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />TYPICAL SECTION THRU WINDOW g MASONRY LAYOUT D <br />54 SCALE: N.T.S. 54 <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT <br />a <br />a <br />o a <br />a <br />8STD. 9THOOK g" <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6-0" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />11 <br />NOTES: <br />1� FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />Q VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />Q SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4" <br />FORM CONCRETE INSET TO <br />CREATE A SOLID BASE FOR <br />112"X91/2"PLYWOOD BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />J <br />J <br />i- <br />r <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />MOUNTING BASE SHOWN <br />IN POSITION <br />GARAGE ENTRY FORM DETAIL <br />2x6 MOUNTING BASE <br />SCALE: N.T.S. <br />�8x8x16 C.M.U. <br />GARAGE DOOR TRACK MOUNTING BRACKET <br />GARAGE DOOR ROLLER GARAGE DOOR TRACK <br />CONNECTION ASSEMBLY <br />:.., GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />Q <br />SCALE: N.T.S. <br />a a a <br />a <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />T1*/ <br />s FF O� <br />2x CRIPPLES @ --� <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1/2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" —� <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING <br />VERTICAL JAM <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />FOP <br />a <br />IARAGE <br />OOR <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. 54 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />SIZE <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />V-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1)LSTA30 <br />4'- 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 1.2d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />\---(2) 2x HEADER SEE PLAN <br />INTERIOR HEADER: <br />S4 <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER <br />• EXTERIOR HEADERS: <br />ONLY <br />(1) 2x SILL PLATE W/ (2) " <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH <br />SIDE <br />' <br />2x STUDS TYP. <br />00 <br />OR <br />SIMPSON HTT4 TYP. <br />Op <br />FN��G <br />U.N.O. SEE N/S4 <br />** HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL Q <br />SCALE: N.T.S. SL) <br />SIMPSON SIMPSON <br />SP4 SP2 <br />2X STUDS @ 24" O.C. <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />LINTEL <br />12 <br />(TYP.) SEE ELEV. <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM C. <br />926 APPLY 3 LAYERS W/ TOTAL <br />THICKNESS 7/8" OVER METAL <br />LATH. FIRST 2 LAYERS 3/8" THICK <br />SIM SON SP2 w/ (12)10d <br />NAIL AT EACH STUD <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING ( ) <br />O/C FIELD <br />2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />CARRIER/GIRDER TRUSS <br />SIMPSON HETA20 w/ (8)10dx1 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />L <br />IN KO BLOCK AT EA. STUD <br />MAIN SPAN <br />MOISTURE BARRIER <br />ROOF TRUSS <br />UPLIFT CONNECTOR <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90' HOOK IN K.O. BLOCK <br />ALT. KNEEWALL ABOVE MASONRY <br />WALL DETAIL <br />SCALE: N.T.S. <br />- PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />kSPLICE NAILS TOTAL) EA. SIDE OF <br />48.,SPLICE STAGGERED <br />@ 8" O/C <br />ATTACH ALL -` <br />EXTERIOR STUDS <br />W/ 4b16d TOENAILS <br />TO P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL rM <br />SCALE: N.T.S. <br />F= 2240 LBS <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />P.T. <br />ATE <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />RECESS <br />LINTEL <br />a <br />SIMPSON SIMPSON <br />SP4 SP2 <br />r <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />r SIMPSON SP4 <br />SP4 <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP4 <br />SIMPSON <br />SP1 <br />SIMPSC <br />SP4 <br />TRUSS BOTTOM CHORD OR 2x4 <br />W/ 2-16d TOE NAILS <br />'BLOCKING <br />@ EACH END <br />w <br />U <br />2x TOP PLATE <br />G <br />V2-16d <br />NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE <br />EQUAL @ 12" O.C. <br />STAGGERED FROM BOT. <br />SEE A/S3 FOR <br />PLATE TO CONCRETE <br />REINF. INFO. <br />TYPICAL INTERIOR NOW <br />BEARING WOOD FRAME WALL j <br />SSCALE: N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />P.L. 1.8E Fb=2400 PSI (AS PER PLANS) <br />° o ° • HTT4 w/ (18)10d NAILS (3610# SPF) <br />° o • HTT5 w/ (26)10d NAILS (4670# SPF) <br />° ° • DTT2Z w/ (8)1/4" x 1 1/2" SDS (1835# SPF) <br />° a ° • HDU2-SDS2.5 w/ (6)114" x 21/2" SDS (2215# SPF) <br />HDU4-SDS2.5 w/ (10)1/4" x 2112" SDS (3285# SPF) <br />_ • HDU5-SDS2.5 w/ (14)1/4" x 21/2" SDS (4065# SPF) <br />• HDU8-SDS2.5 w/ (20)1/4" x 21/2" SDS (5665# SPF) <br />• HDU11-SDS2.5 w/ (30)1l4" x 21/2" SDS (6865# SPF) <br />• 518" DIA. x 12" EPDXIED A.T.R. MIN. 8" <br />EMBEDMENT w/ WASHER & NUT <br />9 • FOR DTT2Z USE 1/2" DIA. x 12" EPDXIED <br />A.T.R. MIN. 8" EMBEDMENT w/ WASHER & <br />NUT <br />• FOR HDU8 USE 7/8" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER & NUT <br />• FOR HDU11 USE 1" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER & NUT <br />HTT / HDU TENSION TIE rN <br />SCALE: NTS S4 <br />SIMPSON SP4 <br />ROOF TRUSS ABOVE <br />2X TOP PLATE /- 2X BLOCKING <br />OVERLAPPING / <br />--10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />-2X P.T. PLATE <br />2X8 P.T. BOTTOM PIATE� <br />C <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON C <br />SP4 <br />" <br />-(2)16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />11 <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />10d NAILS @ 4 A 10d NAILS @ 6" O.C. <br />STAGGERED ST D <br />AGGERE <br />NTRANSOM FRAMING <br />0 o BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" L PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES o E SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6)10dx 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY--5/8"X10" J-BOLTS @ 24" O.C. <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW MAX. (MIN. PER BOTTOM <br />L <br />a <br />2X8 P.T. BOTTOM <br />PLATE <br />UU <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY <br />SCALE: N.T.S. <br />r, <br />Q <br />{�o <br />M z - � <br />o <br />! S= <br />CID <br />¢ o <br />� N <br />M <br />V, a <br />N (D <br />T Y <br />� a <br />ua <br />U0 c E <br />N � <br />R3 }-m <br />o <br />MI�- 12 s <br />J= <br />O= N <br />° <br />`y 8 <br />m <br />Kim <br />ooo? w z <br />M r0 <br />41. <br />M Z a <br />II• J n s'o W w <br />LY a �?"`"°z w w <br />tea= gQ <br />Q W <br />0 m <br />t7E:€�'I£P <br />W�'� �W <br />0c <br />n <br />. <br />0� <br />e F L. <br />w <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />Cl) <br />z <br />W <br />Z <br />M <br />q <br />E <br />Wo <br />a <br />Z® <br />14 <br />o <br />E u <br />9 (6 <br />z <br /><o <br />. <br />0 < <br />0n <br />W0 <br />U <br />, V <br />o� <br />C:)Qz <br />CV � <br />¢¢ <br />az <br />-,�+ L <br />_ <br />4Z <br />H <br />m0 <br />~O <br />ZW <br />z <br />oil <br />cn <br />co <br />f7- <br />o <br />� <br />z <br />go <br />a <br />m w <br />c; <br /><- <br />� <br />=G <br />w <br />>° <br />c <br />C <br />a ¢ <br />a <br />00 S <br />c O <br />0 <br />> M <br />^L1 <br />W\ <br />./ <br />_ <br />N <br />T <br />Q <br />C o <br />CV <br />I_. <br />%%—/ <br />= <br />d- <br />r <br />U <br />.2 <br />V J <br />r <br />l; <br />L(') <br />■_ +- <br />O <br />LO <br />rt— <br />I co C) <br />r <br />C� ce) N <br />o <br />z <br />E a <br />CL <br />E a ? <br />U Q 0 <br />c <br />JOB NO : 19-5332 <br />SCALE : AS NOTED <br />SHEET NO, <br />S4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.