Laserfiche WebLink
(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />VENT OR 2ND FLOOR <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />TYPICAL C.M.U. WALL <br />2x6 / 2x8 WALL BEYOND <br />(2) 2x HEADER TO SIT <br />FLUSH TO THE OUTSIDE <br />Iv <br />STANDARD 3" DIA. TEE <br />3/4" FURRING STRIPS <br />SEE PLAN FOR HEADER <br />SEE PLAN FOR SIZE <br />THREADED 3" DIA. EXTENSION <br />1/2" GYPSUM BOARD <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />CONNECTION <br />SCREW OFF CAP (3" DIA.) <br />W/ DRYWALL SCREWS <br />2x DEAD WOOD @ MID <br />FOR CLEAN -OUT <br />@ 8" O.C. OR 4d <br />POINT w/ (3)12d <br />DRYWALL NAILS <br />SOLID AREAS ARE <br />TONEAILS SPACED <br />MIN. EXTENSION FROM <br />EXTERIOR FACE OF BLOCK <br />STEEL AND GROUT ❑ <br />DOUBLE 2x TOP <br />EVENLY <br />WALL IS 1 1/2" MAXIMUM <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />12 <br />(TYP.) SEE ELEV. <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM C. <br />926 APPLY 3 LAYERS W/ TOTAL <br />THICKNESS 7/8" OVER METAL <br />LATH. FIRST 2 LAYERS 3/8" THICK <br />EACH. 3RD LAYER 1/8" THICK. <br />CRICKET AS REQUIRED/ <br />PLATE <br />HEADER FLUSH TO OUTSIDE OPTION <br />EXTENSION FROM EXTERIOR <br />INTERIOR FULL 8x8x16 BLOCK <br />WALL <br />SIM SON SP2 w/ (12)10d <br />NAIL AT EACH STUD <br />I <br />FACE OF BLOCK WALL IS 21/4" <br />CL DOOR OPENING DOOR OPENING DOOR OPENING <br />LMJFASTENED <br />1/2" EXTERIOR GRADE SHEATHING <br />2x BLOCKING @ EACH END W/ 10d @ <br />TO DRAIN <br />Lm <br />j <br />TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />4" O.C. FROM EACH HEADER FACE <br />EXTERIOR <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING ( ) <br />TO BLOCKING <br />WALL CLEAN -OUT A <br />WALL <br />O/C FIELD <br />(2) 2x HEADER <br />PER PLAN <br />SCALE: N.T.S. <br />2X4 PT STUDS @ 16" O.C. <br />S4 <br />(2) 2X4 PT STUDS UNDER HIP <br />2x BOTTOM PLATE W/ (1)10d @ 8" <br />1ST COARSE 2ND COARSE 3RD COARSE <br />CARRIER/GIRDER TRUSS <br />VARIES O.C. TO EACH HEADER FACE <br />MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE <br />HETA20 w/ 1/2" <br />REFER TO WINDOW PRODUCT APPROVAL <br />COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE <br />TIC <br />NAILS VERTICAL <br />NAILS AT EA. TRUSS VERTICAL WEB <br />SHEETS FOR INSTALLATION INFORMATION BY <br />WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />MANUFACTURER. <br />IN KO BLOCK AT EA. STUD <br />MAIN SPAN <br />2 X 6 (MIN.) FRAME <br />ROOF TRUSS <br />WALL HEADER DETAIL 1 <br />TYPICAL SECTION THRU WINDOW B <br />MASONRY LAYOUT D <br />MOISTURE BARRIER <br />UPLIFT CONNECTOR <br />SCALE: N.T.S. <br />SCALE: N.T.S. 54 <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W! GROUT <br />12 SEE TYPICAL WALL SECTION <br />(TYp) SEE ELEV. PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />SEE SCHEDULE KNOCK -OUT <br />( ) NOTCH LINTEL WHERE REQUIRED <br />DOUBLE 2x4 SPF. #2 BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2) 12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12) 10d (3)10d TOENAILS T&B <br />NAILS AT EACH STUD AS REQ'D <br />__-2x BLOCKING @ MID <br />POINT EVERY OTHER <br />(STTUD W/ (3) Od NAIL <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2) 16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10)10d <br />NAILS AT EACH STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90A HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERALNOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />a d <br />8e STD. 9T HOOK g" <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6'-O" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />NOTES: <br />10 FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />--- PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />BLOCKING P. 0 VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />(� ) PROPERLY. <br />\L—ROOFTRUSS O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />UPLIFT CONNECTOR (SEE SCHEDULE) ® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />L-SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO <br />1/2"X91/2" PLYWOOD CREATE A SOLID BASE FOR <br />BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />Uj <br />J <br />T O <br />MOUNTING BASE SHOWN <br />IN POSITION <br />—2x6 MOUNTING BASE <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />GARAGE ENTRY FORM DETAIL <br />�8x8x16 C.M.U. GARAGE DOOR <br />GARAGE DOOR ROLLER _ <br />CONNECTION ASSEMBLY <br />GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />-TRACK MOUNTING BRACKET <br />\ \GARAGE DOOR TRACK <br />SCALE: N.T.S. d , <br />a a BOTTOM OF MOUNTING B <br />POURED CONCRETE BASE FOR <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />SFF 0 <br />2x CRIPPLES @ <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1 /2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90' HOOK IN K.O. BLOCK <br />VERTICAL JAM ALT. KNEEWALL ABOVE MASONRY WALL DETAIL <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. SCALE: N.T.S. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />WALL PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />dTHAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />° aDOOR STOP PSPN516Z w/ (12)16d NAILSz4f<4 <br />d MOLDING TOP 2 ROWS 10d @ 3" O.C. (14 <br />2 x 6 P.T. GARAGE SPLICE NAILS TOTAL) EA. SIDE OF <br />DOOR 4&, SPLICE STAGGERED <br />J-BOLT <br />TRACK <br />BRACKET <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1'-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1)LSTA30 <br />4'- 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />1 (2) 2x HEADER SEE PLAN <br />S4 INTERIOR HEADER: <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER e EXTERIOR HEADERS: <br />ONLY (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH <br />SIDE <br />2x STUDS TYP. <br />00 t SIMPSON HTT4 TYP. <br />Op O'4 U.N.O. SEE N/S4 <br />HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL rQ_"� <br />SCALE: N.T.S. 54 <br />SIMPSON SIMPSON <br />SP4 SP2 <br />2X STUDS @ 24" O.C. <br />EO <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />RECESS <br />LINTEL <br />d <br />d0 d <br />ATTACH ALL <br />EXTERIOR STUDS <br />W/ 4 16d TOENAILS <br />TO YbP PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL rM <br />SCALE: N.T.S. <br />F= 2240 LBS �7 <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />P.T. <br />ATE <br />a <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />�RECESS <br />j <br />/ LINTEL <br />SIMPSON SIMPSON <br />SP4 SP2 <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />Sp1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />NAILED <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP4 <br />SIMPSON <br />SP1 <br />SIMPSC <br />SP4 <br />TRUSS BOTTOM CHORD OR 2x4 <br />BLOCKING W/ 2-16d TOE NAILS <br />@ EACH END <br />w <br />U <br />2x TOP PLATE <br />2-16d NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAXF. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE <br />EQUAL @ 12" O.C. <br />STAGGERED FROM BOT. <br />SEE A/S3 FOR:N <br />REINF. INFO. <br />PLATE TO CONCRETE <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL j <br />SCALE: N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />P.L. 1.8E Fb=2400 PSI (AS PER PLANS) <br />° o ° • HTT4 w/ (18)10d NAILS (3610# SPF) <br />° e HTT5 wl (26)10d NAILS (4670# SPF) <br />° e • DTT2Z w/ (8)1/4" x 1 1/2" SDS (1835# SPF) <br />° • HDU2-SDS2.5 w/ (6)1/4" x 21/2" SDS (2215# SPF) <br />• HDU4-SDS2.5 w/ (10)1/4" x 21/2" SDS (3285# SPF) <br />_ • HDU5-SDS2.5 w/ (14)1/4" x 21/2" SDS (4065# SPF) <br />• HDU8-SDS2.5 w/ (20)1/4" x 21/2" SDS (5665# SPF) <br />• HDU11-SDS2.5 w/ (30)1/4" x 21/2" SDS (6865# SPF) <br />• 5/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" <br />EMBEDMENT wl WASHER & NUT <br />o • FOR DTT2Z USE 1/2" DIA. x 12" EPDXIED <br />A.T.R. MIN. 8" EMBEDMENT w/ WASHER & <br />NUT <br />• FOR HDU8 USE 7/8" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER & NUT <br />• FOR HDU11 USE 1" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER & NUT <br />HTT / HDU TENSION TIE N <br />SCALE: NTS S4 <br />SIMPSON SP4 <br />�2X <br />TOP PLATE <br />OVERLAPPING <br />—10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />ROOF TRUSS ABOVE <br />/— 2X BLOCKING <br />I <br />In 2X8 P.T. BOTTOM P TE G' <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. B <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON C <br />SP4 <br />10d NAILS 4" <br />Q ° <br />2X8 P.T. BOTTOM <br />PLATE <br />UU <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />-(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />@ 10d NAILS @ 6" O.C. <br />STAGGERED A STAGGERED <br />TRANSOM FRAMING <br />o o BEYOND. <br />PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES o E SHEATHING <br />& 8" O/C FIELD <br />S4 B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12)10d NAILS MASONRY <br />• SIMPSON SP1 wl (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY rR� <br />SCALE: N.T.S. <br />l <br />r> <br />�1 <br />z N S <br />z o <br />J C7 <br />� <br />N <br />_ (M <br />� o <br />N zC1 <br />� <br />J� LL <br />T <br />L <br />U — <br />w <br />L C E <br />(an <br />U 00 <br />w <br />Otx <br />0 8 <br />I I <br />e <br />U <br />Q � o <br />s�o <br />N N <br />h N <br />zo��op z <br />M Z z <br />HJ Co <br />Qto LLui v .� Z a' u7 <br />m <br />WL Z to <br />-d10 <br />N <br />W <br />vx <br />ES��" <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />M <br />M <br />¢2 <br />cos <br />Z <br />g <br />LL <br />F <br />Q <br />z <br />',0 <br />OLL <br />>o <br />0 <br />Z <br />z�ao� <br />O � <br />w z <br />K O <br />Qi <br />Da <br />� 0 <br />wz <br /><o <br />w� <br />C <br />< <br />Na' <br />m <br />o& <br />Z~ <br />Z <br />J <br />r,b <br />f� <br />o <br />�0 <br />d <br />lw <br />W <br />U � <br />ire <br />�z <br />=G <br />o <br />O <br />n � <br />tea' <br />zIa <br />Cc, 3 <br />C)0 <br />In <br />^L, <br />W <br />N <br />,>Ir <br />_ <br />N <br />T' <br />Q <br />C o <br />N <br />� <br />C <br />a O <br />V <br />e � J ,— <br />N M N <br />LO <br />T <br />r <br />ui <br />ih <br />Ch N <br />o <br />z <br />E <br />z <br />cc <br />a <br />E <br />0 _j ¢ o <br />� <br />JOB <br />NO : 19-5331 <br />SCALE : AS NOTED <br />SHEET NO. <br />S4 <br />