CHEMICAL TERMITE TREATMENT NOTES <br />1. " A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE -INSPECTION AND TREATMENT CONTRACT <br />RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER AND ELECTRICAL PANEL." <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST V-0" FROM BUILDING SIDEWALLS. <br />3. IRRIGATION/ SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN V-0" OF THE BUILDING SIDEWALLS. <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES. <br />EXCEPTION: PAINT OR DECORATIVE CEMENTICIOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY TO THE FOUNDATION WALL. <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACK FILL IS COMPLETE. <br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED AND FORMED. <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. <br />PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT. <br />8. MINIMUM 6 MIL. VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER <br />PLACEMENT, RETREATMENT IS REQUIRED. <br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT. <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN V-0" OF THE STRUCTURE SIDEWALLS. <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION <br />ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED. <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. <br />13. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE <br />OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE <br />PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF <br />AGRICULTURE AND CONSUMER SERVICES." <br />14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FORM BELOW AND WITHIN V-0" OF THE BUILDING. THIS INCLUDES ALL <br />GRADE STAKES, TUB BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC. SHALL BE BURIED WITHIN 15'-0" OF ANY BUILDING OR PROPOSED BUILDING. <br />WIND DESIGN CRITERIA <br />WIND SPEED -MPH) <br />140 <br />WIND IMPORTANCE FACTOR <br />+ <br />BUILDING CATEGORY <br />II <br />WIND EXPOSURE <br />C <br />INT. PRESSURE COEF. <br />+/- 0.18 <br />ROOF HEIGHT <br />15 <br />ROOF DLOPE <br />25 <br />EXPOSURE ADJ. COEFF. <br />1.21 <br />AREA (SF) <br />POSITIVE (PSF) <br />NEGATIVE (PSFI <br />10 <br />42.7 <br />-57.1 <br />15 <br />41.7 <br />-55.2 <br />20 <br />40.8 <br />-53.2 <br />25 <br />40.4 <br />-52.4 <br />30 <br />39.9 <br />-51.5 <br />25 <br />39.5 <br />-50.7 <br />40 <br />39.1 <br />-50.0 <br />45 <br />38.7 <br />-49.1 <br />50 <br />38.2 <br />-48.2 <br />75 <br />37.3 <br />-46.3 <br />100 <br />36.3 <br />-44.4 <br />500 <br />31.8 <br />-35.5 <br />56 <br />38.0 -47.7 <br />112 <br />36.2 -44.1 <br />COMPONENTS AND CLADDING <br />ROOF <br />AREA (SF) <br />POSITIVE (PSF) <br />NEGATIVE (PSF, <br />10 <br />24.6 <br />-100.6 <br />20 <br />22.4 <br />-94.0 <br />50 <br />19.5 <br />-85.3 <br />100 <br />17.3 <br />-78.8 <br />WALLS <br />AREA (SF) <br />POSITIVE (PSF) <br />NEGATIVE (PSF) <br />10 <br />42.7 <br />-57.1 <br />20 <br />40.8 <br />-53.2 <br />50 <br />38.2 <br />-48.2 <br />100 <br />36.3 <br />-44.4 <br />500 <br />31.8 <br />-35.5 <br />OVERHANGS (PSF) <br />-133.83 <br />CONNECTOR SCHEDULE <br />UPLIFT CAPACITIES ARE BASED ON SOUTHERN YELLOW PINE (S.Y.P.) <br />UNI FAR NOTED OTHERWISE <br />SIMPSON <br />ID <br />QTY. <br />CONNECTOR <br />UPLIFT <br />FASTENERS <br />T1 <br />1 <br />HTSM16,20 <br />1175 <br />(8) 1OD W/ (4) 1/4"x2 114" TITEN <br />T2 <br />1 <br />T3 <br />1 <br />MSTAM24 <br />1500 <br />(9) 1OD W/ (5) 1/4"x2 114" TITEN <br />T4 <br />1 <br />LTT20B <br />1500 <br />10 10D <br />T5 <br />1 <br />LTA2 <br />1425 <br />(10) 10Dxl 1/2" <br />T6 <br />1 <br />HETA20 <br />1810 <br />(9) 10Dx1 1/2" <br />T7 <br />1 <br />HTT4 <br />4455 <br />(1) 5/8" A.T.R.** (18)-5D#10xl 1/2" <br />T8 <br />1 <br />MGT <br />3965 <br />(22) 10d&5/8" A.T.R.** <br />T9 <br />1 <br />HTT5 <br />5090 <br />(1) 5/8" A.T.R: `* (26) 16d x 2 1/2" <br />T10 <br />1 <br />HTT5 <br />5090 <br />(1) 5/8" A.T.R.** W/ (26) 16d x 2 <br />/12" <br />Tl l <br />1 <br />HGT-2(2 PLY <br />MEMBER) <br />10980 <br />(2) 3/4" A.T.R.** W/ (16) 10d <br />T12 <br />1 <br />HGT-3 (3PLY <br />MEMBER) <br />10530 <br />(2) 3/4" A.T.R.** W/ (16) 10d <br />T13 <br />1 <br />H10 <br />995 <br />x <br />T14 <br />1 <br />MTS12 <br />1000 <br />(14) 10d 1 1/2" OR 10d <br />T15 <br />1 <br />LSTA18 <br />1235 <br />T16 <br />1 <br />HTS20 <br />1450 <br />(24) 10d 1 1/2" OR (20) 10d <br />T17 <br />1 <br />LSTA30 <br />1640 <br />(22) 1OD <br />T18 <br />(2) <br />MST18 <br />2000 <br />(28) 10d 1 1/2" OR 1OD <br />T19 <br />(2) <br />HTS20 <br />2900 <br />(48) 10d 1 1/2" OR (48) 1OD <br />T20 <br />1 <br />ST6224 <br />2540 <br />T21 <br />(3) <br />HTS20 <br />4350 <br />(72) 1OD 1 1/2" OR (72) 1OD <br />T22 <br />(4) <br />HTS20 <br />5800 <br />(96) 10D 1 1/2" OR (96) 10D <br />T23 <br />1 <br />LGT2 <br />2050 <br />30 16D SINKERS <br />T24 <br />(1) <br />LGT3-SDS2.5 <br />3685 <br />26) 16D SINKERS (12) SDS 1/2"x <br />1/2" <br />T25 <br />1 <br />LGT2 <br />2050 <br />30 16D SINKERS <br />T26 <br />(1) <br />LGT3-SDS2.5 <br />3685 <br />(26) 16D SINKERS & (12) SDS <br />1 /4 x2 1/2" <br />OOD TO MASONRY <br />UPLIFT LESS THAN 1810# USE <br />SIMPSON HETA20 <br />OOD TO WOOD UPLIFT LESS THAN 455# USE SIMPSON H5 Wl (8) 8D <br />OOD TO WOOD UPLIFT LESS THAN 14504 MUHL I HAN 4=9 KtUUIKt: H I Z52 <br />CONC. 8" WIDE TIE -BEAM USING SIMPSON EPDXY -TIE <br />'DENOTES ALL THREAD ROD TO BE EMBEDDED 12" MIN. AND SEGURE0-VV7__ <br />IMPSON SET EPDXY OR EQUAL, <br />EPDXOIED ALL THREAD ROD UPLIFT CAPACITIES <br />EMBEDMENT <br />1/2" DIA. <br />5/8" DIA. <br />6" <br />1920 # <br />3768 # <br />8" <br />2560 # <br />5024 # <br />10" <br />3200 # <br />5900 # <br />12" <br />3700 # <br />5900 # <br />NOTE: <br />THESE VALUES ARE BASED ON A307 STEEL ALL <br />THREAD RODS AND SIMPSON SET HIGH STRENGTH <br />EPDXY. THE USE OF HIGHER STEEL WILL YIELD <br />GREATER UPLIFT CAPACITIES FOR DEEPER <br />EMBEDMENTS, <br />INSULATION <br />WALLS: <br />CMU WALLS: R-FOIL 4.1 <br />FRAME WALLS: R-11 <br />CEILING: R-30 <br />INTERIOR FRAME KNEE WALLS: R-19 <br />(WALL THAT BACK UP TO CEILING AREA ONLY) <br />1. CODES AND REFERENCES <br />1.1 2010 FLORIDA BUILDING CODE RESIDENTIAL CODE <br />1.2 AMERICAN CONCRETE INSTITUTE OF STRUCTURAL CONCRETE (ACI 318) <br />1.3 AMERICAN CONCRETE INSTITUTE OF MASONRY STRUCTURES (ACI-530/ <br />ASCE-5/TMS 402 AND SPECIFICATIONS FOR MASONRY STRUCTURES <br />(ACI 530 VASCE 6(TMS 602) LATEST EDITIONS <br />1.4 AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN <br />LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE-7-10) <br />1.5 SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION <br />OF STRUCTURAL STEEL FOR BUILDINGS LATEST EDITION <br />1.6 DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD <br />TRUSSES BY THE TRUSS PLATE INSTITUTE (TPI) LATEST EDITION <br />1.7 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS) <br />LATEST EDITION <br />1.8 AMERICAN PLYWOOD ASSOCIATION DESIGN / CONSTRUCTION GUIDE. (APA) <br />LATEST EDITION <br />2. DESIGN CRITERIA <br />2.1 ROOF LOADING <br />LIVE 20 PSF @ 1.25 DURATION FACTOR <br />30 PSF @ 1.33 DURATION FACTOR <br />DEAD 17 PSF FOR SHINGLE <br />25 PSF FOR TILE <br />2.2 FLOOR LOADING <br />LIVE 40 PSF @ 1.00 DURATION FACTOR <br />DEAD 15 PSF <br />2.3 BALCONY LOADING <br />LIVE 60 PSF <br />DEAD 15 PSF <br />2.4 FOR FLOORING MATERIALS HEAVIER THAN 5 PSF, CONTACT <br />ENDINEER OF RECORD FOR RECOMMENDATIONS <br />2.5 WIND LOADING <br />SEE TABLE FOR CRITERIA <br />DEAD MAXIMUM 10 PSF FOR SHINGLE <br />15 PSF FOR TILE <br />3. SOIL <br />3.1 MINIMUM ALLOWABLE SOIL PRESSURE 2,000 PSF U.N.O. <br />4. CONCRETE <br />4.1 OPERATION INSTALLATION AND PROCEDURE TO COMPLY WITH ACI STANDARDS <br />4.2 CONCRETE & MINIMUM COMPRESSIVE STRENGTH OF 2500 psi AT 28 DAYS <br />(U.N.O.) (3000 psi MIN IN HERNANDO) <br />4.3 REINFORCEMENT REBARS ASTM A615 GRADE 40 (U.N.O.) <br />4.4 WELD WIRE FABRIC (WWF ASTM A185) <br />4.5 LAP SPLICES AND HOOKS SEE TABLE. <br />5. MASONRY <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THE <br />ATTACHED DESIGN AND FOUND IT TO BE IN <br />COMPLIANCE WITH SECTION R301 OF THE <br />2004 FLORIDA BUILDING CODE, RESIDENTIAL. <br />7 Zy►[09 <br />"THE ENGINEER HAS NOT REVIEWED THE <br />PRE-ENGINEERED TRUSS MANUFACTURER'S <br />LAYOUT TO DETERMINE ANY LOAD BEARING <br />CONDITIONS AND RESERVES THE RIGHT TO <br />MAKE ANY CHANGES AFTER TRUSS LOAD <br />INFORMATION IS SUPPLIED TO THE ENGINEER. , <br />TRUSS NOTE <br />5.1 MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM TO ALL REQUIREMENTS <br />OF, "SPECIFICATION FOR MASONRY STRUCTURES (ACI 530.1/ASCE 6/TMS 602)," <br />PUBLISHED BY THE MASONRY SOCIETY; BOULDER, COLORADO: THE AMERICAN <br />CONCRETE INSTITUTE, FARMINGTON HILLS, MICHIGAN: AND THE AMERICAN SOCIETY <br />OF CIVIL ENGINEERS, RESTON, VIRGINIA: EXCEPT AS MODIFIED BY THE REQUIREMENTS <br />OF THESE CONTRACT DOCUMENTS. <br />5.2 GENERAL SPECIFICATION FOR MASONRY STRUCTURES <br />5.2.1 TESTING OF FIELD MATERIALS FOR QUALITY CONTROL IS NOT REQUIRED BY <br />ENGINEER FOR THIS PROJECT. <br />5.2.2 COMPRESSIVE STRENGTH REQUIREMENT IS fm=1500 PSI <br />5.2.3 DETERMINATION OF COMPRESSIVE STRENGTH IS THE ALLOWABLE STRESS METHOD <br />5.2.4 UNIT STRENGTH METHOD IS NOT APPLICABLE <br />5.2.5 QUALITY ASSURANCE IS NOT APPLICABLE <br />5.3 PRODUCTS <br />5.3.1 MORTAR MATERIALS SHALL BE TYPE M OR S GRAY MORTAR <br />5.3.2 MASONRY UNIT MATERIALS SHALL BE 1900 PSI MIN. CONCRETE MASONRY UNIT. <br />5.3.3 REINFORCEMENT, PRE -STRESSED TENDONS, AND METAL ACCESSORIES SHALL <br />BE 40 KSI REBAR (MIN.). <br />5.3.4 WELDED WIRE FABRIC TO BE INSTALLED AS SPECIFIED ON PLAN SET. <br />5.3.5 STAINLESS STEEL IS NOT APPLICABLE. <br />5.3.6 COATING FOR CORROSION PROTECTION IS NOT APPLICABLE. <br />5.3.7 CORROSION PROTECTION FOR TENDONS IS NOT APPLICABLE. <br />5.3.8 PRE -STRESSING ANCHORAGE, COUPLERS, AND END BLOCKS ARE <br />NOT APPLICABLE. <br />5.3.9 JOINT FILLERS ARE NOT APPLICABLE. <br />5.3.10 LINTELS TO BE BY CAST-CRETE UNLESS NOTED OTHERWISE. <br />5.4 EXECUTION <br />5.4.1 PIPES AND CONDUITS ARE NOT APPLICABLE, <br />5.4.2 ACCESSORIES ARE NOT APPLICABLE. <br />5.4.3 EXPANSION AND CONTROL JOINTS SHALL BE AS INDICATED <br />IN PLAN SET. <br />C <br />ASHING NOTES: <br />E GALVANIZED STEEL FLASHING <br />G TO BE DONE AT: A: ALL ROOF <br />CONNECTIONS <br />ALL PLUMBING, ELECTRICAL, AND <br />MECHANICAL ROUGH -INS MUST BE <br />COMPLETE, INSPECTED, AND APPROVED <br />BEFORE REQUESTING THE FRAMING <br />INSPECTION. <br />GEN. INSP. NOTES <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL <br />BE ON THE SITE FOR THE BUILDING INSPECTOR'S USE, OR ALL PROPERTY MARKERS <br />SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY <br />REQUIRED SETBACKS. <br />FOR STRUCTURES BUILT WITHIN AREAS OF THE DESIGNATED WIND BORNE DEBRIS REGION, AS <br />DEFINED IN THE 2010 FBC, ALL OPENINGS SHALL BE PROTECTED IN ACCORDANCE WITH THE <br />REQUIREMENTS OF SECTION R301.2.1.2 OF THE 2010 FBC-R. IF BUILDING IS TO OCCUR WITHOUT <br />OPENING PROTECTIONS, CONTRACTOR TO REQUEST VERIFICATION FROM FOR IN WRITING THAT <br />SUBJECT HOMESITE IS OUTSIDE OF THE DESIGNATED WIND BORNE DEBRIS REGION. <br />6. WOOD FRAMING <br />6.1 DIMENSIONED LUMBER SHALL BE DRESSED S4S, AND SHALL BEAR <br />THE GRADE STAMP OF THE MANUFACTURER'S ASSOCIATION. <br />6.2 ALL LUMBER SHALL BE SOUND, SEASONED, AND FREE FROM WARP. <br />6.3 FRAMING WALLS AND COLUMNS <br />6.3.1 MINIMUM OF 3 PLY S.Y.P. #1 STUD COLUMNS TO BE INSTALLED AT BEAM OR <br />GIRDER TRUSS BEARING LOCATIONS. UNLESS NOTED OTHERWISE. <br />6.3.2 S.Y.P. #1 GRADE OR BETTER FASTEN PLYS TOGETHER USING 16d <br />COMMON NAILS 6" O.C. AS EACH MEMBER IS APPLIED (U.N.O.) <br />6.3.3 4 PLY OR AND LARGER STUD COLUMNS SHALL BE FASTENED TOGETHER <br />AS STATED ABOVE PLUS CS16 COIL STRAPPING WRAPPED AROUND <br />COLUMN WITH A 4" END CAP AT 16" O.C. OR 1/2" < THRU BOLTS <br />AT 24" O.C. <br />6.3.4 ALL FRAMING LUMBER SHALL BE S.Y.P. #1 OR <br />BETTER U.N.O. <br />6.3.5 INTERIOR LOAD BEARING (IF APPLICABLE) WALLS SPACED AT 16" O.C. <br />AND SHALL BE S.Y.P. #1 OR BETTER. <br />6.3.7 INTERIOR NON -LOAD BEARING WALLS SHALL BE UTILITY GRADE <br />OR BETTER. <br />6.3.8 INSTALL BLOCKING IN ALL WALL STUDS OVER 8'-0 AT <br />MID -HEIGHT, AND SHEATHING JOINT. BRACE GABLE END <br />WALLS AT 4'-0 O.C. AS SHOWN IN DRAWINGS <br />6.3.9 ALL LOAD BEARING WALL SHALL HAVE S.Y.P. #1 DOUBLE TOP PLATES <br />AND SHALL BE FASTENED PER 5/S4. BOTTOM PLATES SHALL BE S.Y.P. #1. <br />6.4 ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE <br />PRESSURE TREATED OR NATURAL DURABLE WOOD. <br />6.5 PRESSURE TREATED LUMBER SHALL BE IMPREGNATED WITH A CCA <br />SALT TREATMENT IN ACCORDANCE WITH F.S. 11-W-571 AND BARE <br />THE AMERICAN WOOD PRESERVES INSTITUTE EQUALITY MARK LP-2. <br />6.6 A.P.A. RATED SHEATHING EXTERIOR GRADE. ALL ROOF <br />SHEATHING TO INSTALLED WITH PLY CLIPS (MAXIMUM 24" O.C.). <br />(SEE PLANS FOR SHEATHING THICKNESS.) FOR ALL SHEATHING <br />ATTACHMENT, SEE TYPICAL NAILING SCHEDULE <br />6.6.1 ROOF: SHINGLE, 7/16" MIN. THICK SUPPORTED OVER 24" MAX. SPAN <br />TILE, 1/2" MIN. THICK SUPPORTED OVER 24" MAX. SPAN <br />6.6.2 WALL: 7/16" MIN. THICK SUPPORTED OVER 24" MAX. SPAN <br />6.6.3 FLOOR: CARPET, VINYL, WOOD, ETC., 3/4" MIN. TONGUE AND <br />GROOVE SUPPORTED OVER 24" MAX. SPAN <br />CERAMIC TILE, MARBLE, ETC., SEE MANUFACTURERS <br />RECOMMENDATIONS <br />6.7 ALL NAILING AND BOLTING SHALL COMPLY WITH AMERICAN <br />INSTITUTE OF TIMBER CONSTRUCTION REQUIREMENTS. ALL NAILS <br />EXPOSED TO THE EXTERIOR SHALL BE GALVANIZED. <br />6.8 ALL CONNECTION HARDWARE SHALL BE GALVANIZED AND SUPPLIED <br />BY SIMPSON STRONG TIE CO., USP, KC METAL, OR <br />EQUIVALENT, SUBMIT CUT SHEETS FOR ALL CONNECTION <br />HARDWARE TO ENGINEER FOR APPROVAL. ALL NAIL HOLES SHALL BE <br />FILLED OR AS PRESCRIBED BY THE MANUFACTURER. <br />6.9 BRACING: TEMPORARY BRACING OF THE ROOF SYSTEM SHALL BE <br />INSTALLED PER HIB-91 RECOMMENDATIONS AND SHALL BE UTILIZED <br />AS THE PERMANENT BRACING FOR THE ROOF SYSTEM (U.N.O.) <br />6.10 ALL WOOD FRAMING SHALL BE IN COMPLIANCE WITH THE LATEST NDS <br />EDITION FOR WOOD CONSTRUCTION. <br />NOTE: <br />MISSING DOWELS: WHERE FOOTING DOWELS ARE PLACED INCORRECTLY OR <br />MISTAKENLY ELIMINATED, REPLACE DOWEL AT PROPER LOCATION W/ GRADE <br />40 #5 BAR INSTALL IN SLAB W/5" MINIMUM EMBEDMENT, USE EPDXY GROUT. <br />MISSING TRUSS ANCHORS: TRUSSES WHICH ARE PLACED SUCH THAT AN EMBEDDMENT <br />ANCHOR IS MISPLACED OR MISSING MAY BE FASTENED TO THE MASONRY BOND BEAM <br />USING ONE SIMPSON MTSM16 W/ (4) 1/4"x2 1/4" TITEN SCREWS AND 7-10 D NAILS IN TRUSS, <br />MAS CAP IS 840 #. <br />MISSING ANCHOR BOLTS AT BEARING WALL: <br />EXTERIOR BEARING WALL: <br />IN ADDITION TO THE GENERAL PLACEMENT REQUIREMENTS: <br />1.) 5/8" DIAMETER x 6" EMBEDMENT SIMPSON TITEN HD ANCHORS SPACED <br />A MAXIMUM OF 24" O.C. <br />INTERIOR BEARING WALL: <br />IN ADDITION TO THE GENERAL PLACEMENT REQUIREMENTS: <br />1.) 5/8" DIAMETER x 6" EMBEDMENT SIMPSON TITEN HD ANCHORS SPACED <br />A MAXIMUM OF 48" O.C. IF RESISTING UPLIFT LOADS OR 3 1/2" EMBEDMENT <br />AT 48" O.C. IF RESISTING GRAVITY LOADS <br />ALL PRE-ENGINEERED WOOD PRODUCTS SHALL BE VERIFIED BY TRUSS <br />MANUFACTURER. TRUSS MANUFACTURER SHALL HAVE THE AUTHORITY TO <br />MAKE SUBSTITUTIONS FOR PRODUCTS SPECIFIED ON THE PLANS DUE TO <br />AVAILABILITY OR ECONOMICS. CHANGES SPECIFIED BY THE TRUSS <br />MANUFACTURER SHALL CONTROL. CHANGES MADE AFTER TRUSS <br />ENGINEERING HAS BEEN PROVIDED TO ENGINEER OF RECORD, MUST BE <br />APPROVED BY THE ENGINEER OF RECORD. <br />UPON REVIEW, ENGINEER OF RECORD WILL PROVIDE A REVIEW LETTER <br />INDICATING ANY CHANGE IN STRAPPING OR SUPPORT BASED ON THAT <br />REVIEW. CONSTRUCTION COMMENCING PRIOR TO ENGINEER'S REVIEW IS <br />SUBJECT TO MODIFICATION BASED ON REVIEW LETTER. <br />FRAMING PLAN IS DIAGRAMMATIC IN NATURE AND IS PROVIDED FOR <br />ILLUSTRATION PURPOSES ONLY. TRUSS MANUFACTURER TO PROVIDE <br />SEPARATE LAYOUT AND TRUSS COMPONENT DESIGN SIGNED AND SEALED BY A <br />FLORIDA REGISTERED PROFESSIONAL ENGINEER. <br />ALL PRE-ENGINEERED WOOD PRODUCTS SHALL BE VERIFIED BY TRUSS <br />MANUFACTURER. TRUSS MANUFACTURER SHALL HAVE THE AUTHORITY TO MAKE <br />SUBSTITUTIONS FOR PRODUCTS SPECIFIED ON THE PLANS DUE TO AVAILABILITY <br />OR ECONOMICS. CHANGES SPECIFIED BY THE TRUSS MANUFACTURER SHALL <br />CONTROL. CHANGES MADE AFTER TRUSS ENGINEERING HAS BEEN PROVIDED TO <br />ENGINEER OF RECORD, MUST BE APPROVED BY THE ENGINEER OF RECORD. <br />EXTERIOR CEMENTITIOUS FINISH <br />CEMENTITIOUS FINISH OVER FRAME TO BE A MINIMUM 7/8" IN THICKNESS <br />CEMENTITIOUS FINISH OVER CMU TO BE A MINIMUM 5/8" IN THICKNESS <br />TO MEET ASTM C926 <br />ALL PRE-ENGINEERED WOOD PRODUCTS ARE THE RESPONSIBILITY OF THE <br />TRUSS MANUFACTURER. THE TRUSS ENGINEER IS A DELEGATED ENGINEER <br />FOR THIS PROJECT, AND AS SUCH, IS RESPONSIBLE FOR THE VALIDITY OF THE <br />COMPONENTS PROVIDED. FRAMING LAYOUTS SHOWN MAY BE CHANGED BY <br />THE TRUSS MANUFACTURER. THE DELEGATED ENGINEER IS RESPONSIBLE FOR <br />PROVIDING A FINAL SEALED SET OF ALL CALCULATIONS AND LAYOUTS FOR <br />THIS PROJECT TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO <br />MANUFACTURE OF SAID COMPONENTS. ENGINEER OF RECORD HAS NOT <br />REVIEWED THE PRE-ENGINEERED TRUSS MANUFACTURER'S COMPONENTS AT <br />THIS TIME AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER SUCH <br />INFORMATION HAS BEEN PROVIDED FOR REVIEW. CONTRACTOR, AS PROJECT <br />COORDINATOR, SHALL BE RESPONSIBLE FOR INSURING INFORMATION <br />REQUESTED ABOVE HAS BEEN SUBMITTED TO ENGINEER OF RECORD IN A <br />TIMELY MANNER WHEN AVAILABLE. <br />TRUSS ENGINEER NOTE <br />PRE -CAST AND PRE -STRESSED CONCRETE COMPONENTS SHALL BE USED <br />AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. PRE -CAST <br />LINTELS HAVE BEEN REVIEWED AND PLACED BASED ON DESIGN <br />ALLOWABLE LOAD INFORMATION PROVIDED BY CAST CRETE. <br />THEREFORE, CAST CRETE IS A DELEGATED ENGINEER FOR THIS <br />PROJECT. ENGINEER OF RECORD MUST APPROVE IN WRITING ANY <br />CHANGE IN LINTEL MANUFACTURER. ALL OTHER STRUCTURAL PRE -CAST <br />COMPONENT MANUFACTURERS MUST SUBMIT DESIGN LOAD <br />INFORMATION TO ENGINEER OF RECORD FOR APPROVAL. ENGINEER OF <br />RECORD RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER SUCH <br />INFORMATION HAS BEEN PROVIDED FOR REVIEW. CONTRACTOR, AS <br />PROJECT COORDINATOR, SHALL BE RESPONSIBLE FOR INSURING <br />INFORMATION REQUESTED ABOVE HAS BEEN SUBMITTED TO ENGINEER <br />OF RECORD IN A TIMELY MANNER WHEN AVAILABLE. <br />PRE -CAST NOTE <br />ALL MANUFACTURERED PRODUCTS SUCH AS ROOFING, WINDOWS, DOORS, ETC. <br />ARE SHOWN HEREIN FOR ILLUSTRATION PURPOSES ONLY. THE INFORMATION <br />SHOWN IS THE RESPONSIBILITY OF THE MANUFACTURER. THE MANUFACTURER <br />IS RESPONSIBLE FOR THE VALIDITY OF THE COMPONENTS PROVIDED. <br />ATTACHMENT INFORMATION GIVEN BY THE MANUFACTURER IS PROVIDED <br />HEREIN. CONTRACTOR, AS PROJECT COORDINATOR, SHALL BE RESPONSIBLE <br />FOR INSURING THAT THE APPROPRIATE PRODUCT/COMPONENT IS USED AND <br />THAT IT HAS BEEN INSTALLED PER MANUFACTURER'S SPECIFICATIONS SUCH <br />THAT IT WILL WITHSTAND THE COMPONENTS AND CLADDING PRESSURES <br />REQUIRED BY THE SEALED PLANS. <br />ENGINEER OF RECORD HAS NOT REVIEWED THIS INFORMATION FOR <br />APPLICABILITY OR AS A FORM OF PRODUCT APPROVAL OR ENDORSEMENT. <br />MANUFACTURERS NOTE <br />�co <br />0 <br />'G <br />qb <br />+` No 70658 * L <br />.. <br />TAMPA CIVIL DESIGN <br />5289 EHRLICH ROAD <br />TAMPA, FL 33624 <br />(813) 960-5685 PHONE <br />(813) 482-9128 FAX <br />JEREMY COUCH, P.E. <br />PROFESSIONAL ENGINEER,# 70658 <br />1 HEREBY CERTIFY THAT I HAVE <br />REVIEWED THE ATTACHED <br />DESIGN, AND FIND IT TO BE IN <br />COMPLIANCE WITH SECTION R301 <br />OF THE 2010 FLORIDA BUILDING <br />CODE, RESIDENTIAL <br />THE ENGINEER HAS NOT <br />REVIEWED THE PRE-ENGINEERED <br />TRUSS MANUF. LAYOUT TO <br />DETERMINE ANY LOAD BEARING <br />CONDITIONS AND RESERVES THE <br />RIGHT TO MAKE ANY CHANGES <br />AFTER TRUSS LOAD <br />INFORMATION IS SUPPLIED TO <br />THE ENGINEER. <br />SEALED FOR STRUCTURE ONL Y <br />w <br />U) <br />U <br />z <br />Q <br />U <br />J <br />m J <br />u_ J O <br />Q Q 0 > <br />W p z d <br />z p J w <br />mUILEOj <br />❑ ❑ ❑ ❑ ❑ <br />U <br />Z o <br />J Ld <br />> <br />0 <br />w <br />w <br />0 Of <br />0 <br />J <br />J <br />z Q <br />p Q 0 z <br />m CD <br />CD <br />W UO cV Z <br />F- m <br />_ w <br />_ 0 <br />Q � � o <br />z Z <br />Q og <br />U Z <br />z U <br />ISSUE DATE <br />APRIL 2006 <br />REVISION DATE <br />06116109 <br />0412012012 <br />SHEET <br />Sl <br />STRUCTUI?AL DETAILS <br />STORY I4OMPH <br />