Laserfiche WebLink
35'-0" <br />0 <br />I <br />0 <br />16'-8" 18'-4" <br />1'-4" L. 15'-4" 5'-8" 7'-0" 5'-8" <br />1 » , n 11 » A 1 11 1 n <br />3 <br />2 -8 x 2 -8 W. x 12 D. 8 WIDE 6 2 -0 4 -0 x3 -0 <br />CONC. FTG. W/ 2 - #5 _ MONO A/C PAD <br />REBARS E.W. i i FOOTING 0s2 <br />I I <br />1 ■ ■JJ----------------- T------- -- ------ --- ■ • ■ ■ ■ <br />CDI fUUIING \1 ' ao CD00 <br />' <br />I • <br />0 <br />I <br />loo <br />0I <br />cp <br />3 <br />I <br />in S2 <br />00 <br />I <br />i� <br />0 <br />I <br />t� <br />I c 9 <br />w 1 <br />oi� 1 <br />S2 <br />00 <br />3-3 3-10 1 -41 6-10NO <br />I <br />I <br />I <br />1 <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />W, &XXXAXXXXXXYA <br />F <br />------------------------- --- ----- 2 - #4's DIAGONAL AT <br />J '�i 1 <br />I I <br />ALL INTERIOR SLAB a' <br />1 1 1/4" RECESS 6 CORNERS (TYPICAL) <br />■ i FOR S.G.D. s2 n <br />1 1 F 1 OI-11 <br />2 -7 <br />I I I I <br />IIII GARDEN I II <br />`IN i i iii TUB I i <br />I c< it <br />I I I � I I ��i�/ I - ■_ <br />■ I I I N I I 13 -1" ULi N6" �x — <br />I <br />oo i SHG'#E� <br />i �ll�-lam �./')�\\ 2'-4411 <br />\ 4 <br />c -J L----------J L-----------J-L----- <br />,� ELEVATION AT 0'-0" (ASSUMED) `� i i i I^TUg \�I i i i i L <br />■ I 4 THICK, 2500 OR 3000 P.S.I. <br />CONCRETE SLAB ON GRADE W/ ---------' I I 3 -0 <br />6x6 W1.4xW1.4 MESH OVER 6 r------------ <br />MIL. VAPOR BARRIER ON CLEAN, 8" THICKENED EDGE FOR <br />WELL - COMPACTED, TERMITE I 1 i" ( ; i i SHOWER RECESS W/ (1) i ■ <br />TREATED, GRANULAR FILL OR I i �� `--' I 1 #5 BAR CONT. <br />BORATE TREATMENT ON FRAME 11 11 <br />I -T II II <br />COMPONENTS N i i^ " ( -`� \I i i 1 <br />10'�1I ; <br />I Ill <br />oo i t l I L----J I I ■ <br />I <br />ELECTRICAL I 20 -1" <br />CONDUIT,TO-- <br />ISLAND <br />I I D.W. <br />III c <br />SINK DISP Wr=1;il I-----� <br />rr <br />N- <br />1I <br />■ II,iI;I 8, » <br />-5� <br />c' <br />1 I 1 F====c=� <br />OPT. II <br />■ i REF. I <br />-a --------------- <br />-1---____J 1 <br />-----g_ ---- <br />I <br />PROVIDE COPPER LIB <br />I <br />■ I ICE MAKER <br />15'-0" <br />■ <br />I I <br />2'-�" 3'-10" 4'-5if <br />" 1 <br />■ ■ ■ ■ IM <br />II■ - ■ I - <br />3'-0" x 1'-8" W. x 12" D. <br />CONC. FTG. W/ 2 - #5 <br />REBARS E.W. <br />8'-0" <br />10'-4" 4'- <br />0 <br />T <br />CV <br />I <br />0 <br />T <br />i� <br />r-------------a-- <br />II <br />II , <br />1 00 <br />1 1 1 I p . 1 1 1 1 <br />■ <br />I 1 E-==J <br />Li <br />F _ � Ni i <br />■ <br />I <br />F----I I (l— III II j <br />1 <br />I II LL—HI <br />I I I I I <br />) <br />Ws2 <br />/H. <br />--------- ---- ,--------------------------J <br />W.H. I <br />M <br />PLATFORM L-------- ---------------- <br />I ABV. 24" x �* <br />24" x 18" H. I <br />`� <br />I � I <br />N <br />I I <br />WATER SOFTNER o 10'-0" <br />■ <br />LOOP & DRAIN r <br />1 INSTALL 1/2" ANCHOR BOLTS 1 <br />1 AND 2" DIA. WASHERS AT 2'-0" <br />O.C. (MAX) CENTERED ON WALL. <br />i s2 (REFER TO FLOOR PLAN FOR <br />00 I i WALL THICKNESS AND LOCATION) I <br />co 1 I F-j �I I <br />■ <br />S2 <br />------------------------ __ji CONTROL JOINT <br />-- - j-----------I <br />°O <br />I �I---- <br />Zj I <br />a; I <br />o <br />N <br />> <br />o <br />1 ; 20'+-0» <br />I I <br />1 <br />■ <br />-- <br />-I I <br />I 1 <br />1 <br />I <br />I <br />3/4" DP. x 13" W. <br />#■ 9 RECESS FOR <br />8'i gn s2 GARAGE DOOR <br />5 8" <br />1 <br />I <br />• <br />H.B. <br />I <br />�0 <br />2'-4" <br />35'-0" <br />16'-0" <br />20'-8" <br />2'-4" <br />00 <br />0I <br />00 <br />I <br />T <br />N <br />0 <br />I <br />T <br />CV <br />I <br />I <br />00 <br />00 <br />I <br />c 3 <br />Lr, s2 <br />200 <br />I <br />FOUNDATION PL <br />WINDOW SEAT <br />i <br />3'-3" 3'-10" 1'-4'1 6 <br />I I <+- <br />i <br />■ ■ ■ ■ <br />1 <br />I <br />1 1/4" RECESS <br />■ i FOR S.G.D. <br />I <br />I <br />I <br />I <br />I <br />I <br />■ <br />■ i ,� ELEVATION AT 0'-0" (ASSUMED) <br />4 THICK, 2500 OR 3000 P.S.I. <br />i CONCRETE SLAB ON GRADE W/ <br />6x6 W1.4xW1.4 MESH OVER 6 <br />MIL. VAPOR BARRIER ON CLEAN, <br />WELL - COMPACTED, TERMITE <br />TREATED, GRANULAR FILL OR <br />BORATE TREATMENT ON FRAME <br />COMPONENTS <br />■ i ELECTRICAL 1 <br />I CONDUIT, N <br />ISLAND I D.W. <br />1 <br />j _L- -- -� <br />==F====F - 1 ao <br />ff_L mil wI i CL 1�-11 `-%`11 1 -4 <br />II gI �I m z 00 L__. <br />I I I= I N to o I I 1I- <br />1I <br />NOTES: <br />-NOT ALL REQUIRED FLASHING IS INDICATED ON DRAWINGS. <br />PROVIDE FLASHING PER FBC 1403 AND 1503. <br />-FLASHING SHALL BE INSTALLED AT (1) WALL AND ROOF <br />INTERSECTIONS (2) WHEREVER THERE IS A CHANGE IN ROOF SLOPE <br />OR DIRECTION, AND (3) AROUND ROOF OPENING, WHERE FLASHING IS <br />OF METAL. THE METAL SHALL BE CORROSION RESISTANT WITH A <br />THICKNESS OF NOT LESS THAN 0.019 INCH (26 GAGE (0.551 MM) <br />GALVANIZED SHEET). <br />ALL MANUFACTURED PRODUCTS SUCH AS ROOFING, WINDOWS, DOORS, <br />ETC. ARE SHOWN HEREIN FOR ILLUSTRATION PURPOSES ONLY. THE <br />INFORMATION SHOWN IS THE RESPONSIBILITY OF THE <br />MANUFACTURER. THE MANUFACTURER IS RESPONSIBLE FOR THE <br />VALIDITY OF THE COMPONENTS PROVIDED. ATTACHMENT INFORMATION <br />GIVEN BY THE MANUFACTURER IS PROVIDED HEREIN. CONTRACTOR, <br />AS PROJECT COORDINATOR, SHALL BE RESPONSIBLE FOR INSURING <br />THAT THE APPROPRIATE PRODUCT/COMPONENT IS USED AND THAT IT <br />HAS BEEN INSTALLED PER MANUFACTURER'S SPECIFICATIONS SUCH <br />THAT IT WILL WITHSTAND THE COMPONENTS AND CLADDING <br />PRESSURES REQUIRED BY THE SEALED PLANS. ENGINEER OF <br />RECORD HAS NOT REVIEWED THIS INFORMATION FOR APPLICABILITY OR <br />AS A FORM OF PRODUCT APPROVAL OR ENDORSMENT. <br />NOTE: <br />BUILDING SLABS SHALL HAVE CONTROL JOINTS IN ACCORDANCE W/ <br />ACI224-3R <br />ALL CONTROL JOINTS IN LIVING AREA TO BE 10'X10' SQ. <br />ALL CONTROL JOINTS TO BE 1" DEEP. <br />■ = FILLED CELL W/(1) #5 VERTICAL REBAR IN MASONRY <br />CELL FILLED SOLID w/ CONCRETE. VERT. REINF. SHALL <br />BE HOOKED INTO BEAM ABOVE & FTG. BELOW PROVIDE <br />25" MIN. LAP WHERE SPLICED & WIRE TOGETHER. <br />= FILLED CELL W/(2) #5 VERTICAL REBAR IN MASONRY <br />CELL FILLED SOLID w/ CONCRETE. VERT. REINF. SHALL <br />BE HOOKED INTO BEAM ABOVE & FTG. BELOW PROVIDE <br />25" MIN. LAP WHERE SPLICED & WIRE TOGETHER. <br />• = FILL CELL TO THIRD COURSE (NO REBAR) <br />(2) 24" #5 REBAR PLACED DIAGONAL <br />' AT CORNERS <br />LLB- -�LJ <br />,` 0 C <br />1 <br />6 <br />�` �.••' G E•N <br />I <br />1 <br />4 <br />" No 70658 •: <br />�it <br />cD <br />• .1 <br />■ I <br />I REF. I <br />9 :• STATE OF <br />---------------- <br />-L---__- <br />--- <br />., • 4 O R " <br />•O•• <br />'9/15 <br />AN <br />ALL PLUMBING, ELECTRICAL AND <br />MECHANICAL ROUGH -INS MUST BE <br />COMPLETE, INSPECTED AND APPROVED <br />BEFORE REQUESTING THE FRAME <br />INSPECTION <br />TAMPA CIVIL DESIGN <br />'?-A 1P ,.. f73 ;�i <br />JEREMY COUCH, P.E. <br />PROFESSIONAL ENGINEER # 70658 <br />1 HEREBY CERTIFY THAT I HAVE <br />REVIEWED THE ATTACHED DESIGN, <br />AND FIND IT TO BE IN COMPLIANCE <br />WITH SECTION R301 OF THE 2010 <br />FLORIDA BUILDING CODE, <br />RESIDENTIAL. <br />THE ENGINEER HAS NOT REVIEWED <br />THE PRE-ENGINEERED TRUSS MANUF. <br />LAYOUT TO DETERMINE ANY LOAD <br />BEARING CONDITIONS AND RESERVES <br />THE RIGHT TO MAKE ANY CHANGES <br />AFTER TRUSS LOAD INFORMATION IS <br />SUPPLIED TO THE ENGINEER. <br />SEALED FOR STRUCTURE ONL Y - <br />n r a 11x17 BLACKPOINT <br />= 1' . 22X34 ENABLED <br />z <br />m <br />O <br />J <br />U <br />J <br />J <br />J <br />J <br />J <br />W <br />-•� <br />� <br />Q <br />p <br />O <br />Q <br />�Z0_!w <br />Z <br />W <br />J <br />IIm <br />J <br />m0u.Oj <br />❑ ❑ ❑ ❑ ❑ <br />U <br />zo <br />w <br />Of <br />w <br />0 <br />Q <br />w <br />cr <br />0 <br />�_ <br />0 <br />O <br />J <br />J <br />z <br />Q <br />Q <br />z <br />z <br />mM <br />0 <br />W <br />D <br />0 <br />W <br />W <br />0 <br />N z <br />0 <br />o� <br />N� <br />m <br />T <br />2 <br />~ w <br />g o <br />O_ o <br />0 <br />Q <br />% <br />z <br />z <br />ISSUE DATE <br />MARCH 2O07 <br />DRAWN BY <br />SIMPAD <br />DESIGN BY <br />INLAND HOMES <br />REVISION DATE <br />12131110 <br />02105113 <br />SHEET <br />2 <br />FOUNDA TION <br />PLAN <br />