CROSS BRACING DETAIL (TYP.) 1 <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. Dg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKINGBETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP - <br />MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. 1 A <br />----Z-WOOD TRUSS -! <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />4" <br />V-4" <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />CN <br />T <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />TRUSS <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />„ 2x8 #2 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />2X4 CONT. AT-/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />K <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />(2) 12D NAILS t <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />z <br />O <br />Q <br />w <br />J <br />w <br />w <br />w <br />U) <br />WOOD POST. SEE FLR <br />PLAN FOR SIZE & BASE <br />CONNECTION <br />4" <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />V-4" <br />SEE <br />PLAN <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />CN <br />2 ENTRY PORCH SILL 14 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />FOR COLUMN INFO WOOD OR MASONRY <br />INTEGRATE MASONRY ABOVE MASONRY <br />KNEEWALL INTO CMU BASE OR PIER SEE FLOOR <br />MAIN HOUSE PER ELEVATION IF PLAN FOR COLUMN 41,I <br />REQUIRED INFO <br />MASONRY KNEE WALL MAX 3 <br />COURSES w/ TOP K.O. COURSE CMU BASE W/ (1) #5 1 j <br />T <br />. FILLED CELL VERTICAL EACH <br />SPAN MAX 6-8" CORNER FILLED 1 1 <br />MAX 3 SOLID. SEE ELEV. <br />COURSE FOR BASE SIZE <br />(3) #5's EA. WAY <br />1 1 <br />8 <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />-#5 REBAR CONT <br />@ SLAB LEVEL <br />-EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />SLAB PORCH SLAB SEE <br />LEVEL FOUNDATION PLAN <br />(2) #5's CONT. T&B w/ C14 z <br />CONTRACTOR TO INSTALL SEE CUT <br />MIN 3" x 3" WEEP HOLE SECTION FOR #3 STIRRUPS AT 4'-0" '- <br />ALONG w/ PITCHING SLAB MORE INFO WHEN DEPTH <br />EXCEEDS 30" V-4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL r16 <br />SCALE: N.T.S. <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />-#5 REBAR CONT <br />@ SLAB LEVEL <br />-EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />SLAB PORCH SLAB SEE <br />LEVEL FOUNDATION PLAN <br />(2) #5's CONT. T&B w/ C14 z <br />CONTRACTOR TO INSTALL SEE CUT <br />MIN 3" x 3" WEEP HOLE SECTION FOR #3 STIRRUPS AT 4'-0" '- <br />ALONG w/ PITCHING SLAB MORE INFO WHEN DEPTH <br />EXCEEDS 30" V-4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL r16 <br />SCALE: N.T.S. <br />W/ (1) #5 CON <br />SIMPSON LSTA18 SEE PLAN <br />A -A ALTERNATE BLOCKING w/(12)10dNAILS ----------� SIMPSONHUC410w/(14) F-----------7 1 <br />CENTERED AT I I I I I FOR CANT. <br />DETAIL INTERIOR BEARING SPLIT TO TIE I 16dINTOBEAM-SEE ) <br />10d INTO BEAM -SEE <br />((`j-J BEAMS TOGETHER I I I I I <br />I I ROOF PLAN FOR MORE I I <br />I INFO <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />2° <br />�k . 11 <br />w <br />4" z U)) <br />PORCH SLAB SEE a N <br />FOUNDATION PLAN w <br />z <br />W/ #3 STIRRUPS AT C14 z <br />4'-0" WHEN DEPTH . r- <br />EXCEEDS 30" LOWER OR <br />GARAGE SLAB <br />„-4„ SEE PLAN <br />LARGE STEP DOWN 17 <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />I I SEE FLOOR PLAN FOR I <br />COLUMN SIZE & BASE I I I 7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN I CONNECTION INFO I I _ REQ'D ONLY WHEN <br />FOR COLUMN SIZE L — — — — — — — INDICATED ON BM. <br />& ADDITIONAL INFO. SCHEDULE/PLAN <br />7/16" OSB FLITCH PLATE L J SEE FLOOR PLAN OR <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />OPTION A INDICATED ON <br />SC EDULEIPLANM OPTION B CONNECTION INFO OPTION C <br />EXTERIOR SHEATHING COMMON BM. TO POST ATTACHMENT A <br />ATTACHED PER SEE ROOF PLAN <br />2x4 STUDS w/ SIMPSON NAILING SCHEDULE FOR BEAM SIZE & SCALE: N.T.S. BM. SPLICE OVER <br />S <br />AT BASE SEE J/S6 FOR A A <br />P1 w/ (10) 10d NAILS CONNECTION INFO. CENTER OF POST <br />MORE INFO. <br />SEE PLAN FOR <br />TOP OF SEAM <br />2x4 BASE PLATE W/ o o a <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR o o o I <br />SIMPSON MTS12w/ ----� <br />(14) 10d x 1 1/2" NAILS SIMPSON (2) HTS20 w/ (14) <br />TO FLOOR GIRDER 10d NAILS TYP. U.N.O. SEE PLAN FOR <br />BELOW @ 16 O.C. CANT. IF <br />SEE FLOOR PLAN FOR INDICATED <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />16" FLOOR SYSTEM FLOOR GIRDER MIDDLE <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />CORNER SEE FOUNDATION <br />SECTION @FLOOR PLAN FOR MORE INFO <br />5" <br />CONNECTION 22 COMMON BM. ATTACHMENT 18 <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL r7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d • <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE: 1/2" = V-0" <br />COMMON TRUSS <br />W/ INTERIOR BRG. <br />SEE PLAN FOR <br />CONNECTIONS <br />V INFO. <br />TRUSS/ <br />_ rHE <br />OP WALL <br />EE PLAN <br />Y2" CDX PLYWOOD OR Y16" O.S.B.MIN. (2) 2x8 #2 SYP <br />SHEATHING REQ'D FROM BOTTOMDER. SEE Q/S4 FOR <br />OF WALL TO ROOF SHEATHINGEQ'D CONNECTIONS <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES -- --�. <br />2x4 #2 SPF STUDS @ <br />12" O.C. W/ USP SPT22 <br />- ��— @ BASE & SPT24 @ <br />u TOP <br />2x4 #2 SYP P.T. PLATE W/ <br />Y$' EPDXY ANCHOR OR <br />2" J-BOLT OR Y2 TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />SEE PLAN MAX. MIN. 6" EMBEDMENT <br />24" STEPS -- <br />a ° cX a x - <br />SEE PLAN FOR OPT. <br />STAIR INFO. IF <br />CONCRETE STAIRS Q <br />FORMED & POURED ° MAIN HOUSE <br />W/ (1) #5 EACH STEP ° ° ° SLAB <br />d <br />(2) #5's CONT. T&B <br />W/ #3 STIRRUPS AT <br />a ° 4'-0" WHEN DEPTH <br />a - ° ° EXCEEDS 30" <br />GARAGE OR `" z1 ° ° <br />e <br />LOWER SLAB ' 8 <br />SEE PLAN ° <br />1'-4" <br />SECTION GARAGE MONO 21 <br />SCALE: N.T.S. <br />x <br />r <br />CD <br />�. O <br />> W <br />CO—,��x <br />y c0 O �.- <br />N <br />y w C-i R <br />•� E s c <br />LL- <br />w o.�. <br />[� u 3 [a <br />r <br />w m <br />,u <br />d- U <br />r <br />f, cM <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W vE <br />I- o <br />,Q Np <br />2 # LL <br />C', a d <br />Q @ � u_ aw <br />J Z <br />t9 0 O �o <br />L W _ 0 <br />(q NcD m L Q <br />W 0 Nz a <br />W U5 °' °' J r- w <br />Z LO M U G H <br />o d ❑O❑ <br />z <br />W <br />arm <br />z N <br />0 <br />og <br />z <br />V <br />2 <br />�-14-1 <br />z <br />.00 o w. <br />N Ln <br />c— y <br />U <br />— E m <br />8 I' ` <br />L <br />U o <br />C J� <br />o w <br />Z <br />M <br />M Q <br />=o >� <br />0 p �� <o <br />n- z <br />N V ❑a <br />l'— ti �o UO <br />O <br />Z �� o�o1 <br />o < <br />t wo <br />�� <br />m <br />z co �U = <br />m J o '¢ w <br />° z <br />S o< go <br />w <br />M <br />W <br />�. <br />N= <br />2 <br />Jw 06 <br />o <Q ;o <br />M 0 <br />O <br />z�a c� 3 <br />=O = <br />0 <br />J <br />> Ln <br />O °' <br />m <br />o <br />>✓ 00 <br />co OCN <br />CO <br />Cr <br />co <br />CL C0 Ln <br />M O <br />U')N Ln <br />r Q C r <br />T <br />c'M C` o <br />M 7 00 N LO Z <br />Z E O <br />d U ° Q p <br />JOB NO: 23-06102 <br />SCALE: AS NOTED <br />SHEET NO. <br />D1 <br />