My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36351 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36351 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 4:21:17 PM
Creation date
2/28/2025 11:07:27 AM
Metadata
Fields
Template:
Building Plans
Street #
36351
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6700
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3/4" PLYWOOD <br />DECKING <br />FLOOR <br />SYSTEM <br />T <br />�T <br />CONT. HANDRAIL <br />RETURN TO_ <br />WALL DETAIL <br />A jSCALE: NTS <br />STAIR CALCULATIONS: <br />TOTAL R I S E = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />42" KNEE WALL WITH <br />1x8 CAP & CASING <br />USP MP3 CLIP EA. <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />16 ` <br />15 <br />36" H. CONT. <br />14 <br />GRASPABLE <br />13 o RAILING <br />`M <br />I <br />12 <br />I <br />` <br />I <br />I <br />1 x TR EAD <br />10 \ ' . \ <br />i �I� <br />(TYP.) <br />9 <br />8 \ �2 <br />STORAGE <br />1 oo <br />1 <br />UNDER 7 `, <br />I <br />- <br />STAIRS 6\ <br />2x FRAMED <br />WALL <br />4 �\I <br />1x RISERS <br />s <br />(TYP.) <br />, <br />2x FRAMED <br />(3) 2x12 <br />2 <br />1 <br />WALL <br />STRINGERS <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)- 1/4"x 3 1/2" TAPCONS @ <br />16"o.c. AND 3" FROM EA. END. <br />TYP. STAIR SECTION <br />SCALE: 1/2" = V-0" <br />SEE PLAN FOR LANDING DEPTH I <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1; <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM OI <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENE <br />LANDING FOF <br />STRINGERS l <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />N <br />v <br />140C <br />REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.* <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS - <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />* SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />EXTERIOR WALLS <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />J <br />S6 <br />TYP. <br />U.N.O. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />OA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />1812 X 251 <br />S.H. <br />13 <br />20X383 <br />182X37 <br />S.H. <br />14 <br />20X505 <br />182X50 <br />S.H. <br />15 <br />20 X 63 <br />1812 X 621 <br />S.H. <br />16 <br />20X72 <br />182X712 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 2 <br />S.H. <br />iH3 <br />27 1/4 X 38 s <br />26 x 37 a <br />S.H. <br />1 H4 <br />27 1 X 50 a <br />26 x 50 <br />S.H. <br />1H5 <br />274'X63 <br />26X621/2 <br />S.H. <br />1 H6 <br />271 X 72 <br />26 X 71 112 <br />S.H. <br />22 <br />37 J4 X 26 <br />36 2 X 25 1/2 <br />S.H. <br />23 <br />37 a X 38 g <br />36 2 X 37 3/4 <br />S.H. <br />24 <br />37 4 X 50 <br />36 2 X 50 <br />S.H. <br />25 <br />37 a X 63 <br />36 X 62 1/2 <br />S.H. <br />26 <br />37 a X 72 <br />36 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 2 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 2 X 25 <br />S.H. <br />33 <br />54X38g <br />522X37 <br />S.H. <br />34 <br />54X50g <br />522X50 <br />S.H. <br />35 <br />54 X 63 <br />52 2 X 62 2 <br />S.H. <br />36 <br />54 X 72 <br />52 2 X 71 2 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 7314 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />%M 1/2 WALL OR vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The V1/AL L L E G E N D <br />RAILING PER SPECS rn greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />W = Winders: <br />= (n o <br />(7 � M Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />= TECH CENTER LU N� foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread MASONRY HGT. @ 8'-8" A.F.F. <br />v T-9" 5'-11" 2668 11 '4' D2 depth of not less than 6 inches at any point within the clear width of the stair. <br />H1 �N = _ _ _ _ _ _ _ _ _ _ 2668 O Nosings: TYP. 2x FRAME WALL <br />D2 - �---------- BF <br />ONosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />A &1413 <br />I H1 9/16 inch or a bevel not exceeding % inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />I I I I inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing BEARING WALL <br />DRYER VENT TY �� projection by more than 318 inch within a stairway. <br />THRU SIDE WALL I 5068 BF 1 11 10 9 8 7 6 5 4 108 Handrails: INTERIOR BEARING WALLS NOTED "FLOOR <br />I D. <br />LAU N -�� Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more BEARING ONLY" ARE FLOOR SYSTEM <br />J I C---------- -- ---- p 9 <br />Q 1 8'-0" FLAT CLG o 2652 R&S risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of SUPPORTING ONLY AND REQUIRES NO <br />TILE ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be UPLIFT CONNECTORS TO FLOOR SYSTEM <br />in continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />3-11" 3-10" - ------x <br />N above the lowest riser] f the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />HANSON BOX I W H A\R N terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />AREA TABULATION <br />@ 36" A.F.F. (�- 4068 handrails. <br />00 a BF Grip -size: <br />�., 5-02' 5'-101, Handrails with a circular cross section shall have an outside diameter of not less than 1114 inches and not greater <br />r CD <br />WIRE SHELF 9'-5' N N than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. g FIRST LIVING 728 S.F. <br />a, @ +54" A.F.F. �' j Guards: SECOND LIVING 1036 S.F. <br />6' <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, TOTAL LIVING 1764 S.F. <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />3 horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, LANAI 60 S.F. <br />S6 I D2 porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the GARAGE 379 S.F. <br />TYP. I adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have ENTRY <br />iv I N SIM. W/ (1) openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in 62 S.F. <br />U.N.O. 5068 I _G.T. _ i�. _ MSTAM36 diameter. TOTAL SQ. FT. <br />3 11' 6 BF 2 " 11'-2" STRAPS @ Under -stair protection: 2265 S.F. <br />D2 r I BASE Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and I N S U LAT I 0 N R E Q <br />1 u) any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />SIM. W/ (1) BEDROOM 3 ;� BEDROOM 2 <br />MSTAM36 8'-0" FLAT CLG. I 8'-0" FLAT CLG. LOCATION R-VALUE / TYPE <br />STRAPS @ CARPET I CARPET EXT CONC WALL R-4.1 HIGH PERM <br />01, <br />BASE I EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EGRESS* EGRESS* EXT FRAME 2 x 6 R-19 KRAFT FACED <br />I 25 H CONDITIONED CEILING R-30 BLOWN -IN <br />25 (INSTALL BAFFELS AT EAVE) <br />j © p2)� () <br />22 39 © j p2 H1 GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />H1 D1 D1 JAMB STUD OVER U) <br />I I ENTRY TO BE <br />I I CONNECTED DOWN <br />I I PER DETAIL 6/D2 <br />B'-1 n" 5'-1 n" R'_R" F'-R" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Ed. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir, per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />SECOND FLOOR PLAN -B <br />SCALE: Y4"=1'-0" <br />c� <br />.r- <br />as <br />LA- <br />N <br />Q r� N <br />,E <br />3 3 <br />�dd� <br />L d C p <br />C .'m T <br />N d A <br />c E <br />fO o <br />a v <br />0 <br />MHO. <br />.C'J' <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />Q <br />EE S <br />O N 8 (o n <br />V <br />wO J <br />co 46 <br />Q <br />J LL ly rL x U <br />Z <br />13Z <br />�o� 0 o <br />_ <br />j (6N(_O m uu Q <br />LLWoo <br />a,0w <br />U) CV Z 6 QU 2 <br />N Q U (n H <br />O U 110 <br />Z <br />W <br />.Z m <br />7_ n <br />J� <br />U) <br />N <br />Cl- <br />N <br />z o <br />c <br />�-J <br />0 <br />emu✓ <br />V <br />0 <br />w g <br />��.• <br />U <br />s�g <br />r <br />r <br />U ) <br />0 <br />M <br />J <br />O 5' <br />Z <br />Z <br />< <br />LL <br />ZO <br />} ry <br />Q O <br />a p <br />@ U <br />z® <br />oa <br />H n7 <br />< 0 <br />�U <br />CO1= <br />o <br />ro <br />pQa< <br />ao <br />pZ <br />ZCO <br />L <br />w� <br />Up <br />w� <br />d J <br />. <br />a Z <br />m 0 <br />oC, <br />Z <br />mCJ <br />J <br />Nm <br />Q� <br />Q� <br />�Z <br />W <br />T > <br />O <br />m <br />oLL <br />a ¢ <br />az <br />h W <br />o_ <br />5 <br />OM <br />Y <br />d F <br />ZI¢TJ <br />C O <br />,o <br />i <br />> Ln <br />0 <br />a� <br />m <br />O <br />00 <br />CID <br />(.0 <br />� <br />fT <br />C <br />T <br />L.L <br />V / <br />m_ <br />Ln <br />O <br />M <br />CV) <br />O <br />LC) <br />T <br />Q <br />M N <br />r <br />.� <br />T <br />M `% <br />o <br />cc <br />00 <br />i� LO <br />Z <br />Z <br />E O <br />co <br />m <br />a <br />E <br />U °� <br />v �? <br />Q <br />JOB <br />NO: <br />23-06102 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.