My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36476 Flats St
Zephyrhills
>
Building Department
>
Building Plans
>
36476 Flats St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 5:57:26 PM
Creation date
2/28/2025 11:08:02 AM
Metadata
Fields
Template:
Building Plans
Street #
36476
Location
Flats St
Contractor
Lennar
Building Plans - Permit #
5921
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I L I I I I I I t I I I I I II ' J- 1' 1 1- 1 1 ' _' I 1— 1 <br />- -L '1 ' I I _ lug ---1-1 1-111 1 1 - - -- — — - -I <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />FLOOR PLAN <br />r <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAILS <br />4 <br />ELECTRICAL PLAN <br />5 <br />0 <br />ROOF PLAN 1140 <br />6 <br />FOUNDATION PLAN LL <br />7 <br />8 <br />SN <br />SN 1 <br />FRAMING PLAN Ct <br />LINTEL PLAN <br />STRUCTURALNOTES <br />DETAILS <br />ABBREVIATIONS <br />AB or A.B. Anchor Bolt <br />ABV or Abv. Above <br />FIX or FXD Fixed <br />FLR or Flr. Floor <br />RA or R/A or R.A. Return Air <br />RAD or Rad. Radius <br />AC or A/C Air -Conditioner <br />FLR SYS or Ar Sys Floor System <br />RAG or Rag. <br />Return Air Grill <br />S3 <br />DETAILS <br />ADJ orADJ. Adjustable <br />AFF or A.F.F. Above Finished Floor <br />FOM or F.O.M. Face Of Masonry <br />FP or F.P. Fireplace <br />REC or Rec. <br />RECEPT <br />Recessed <br />Receptacle <br />S4 <br />DETAILS <br />AHU or A.H.U. Air Handier Unit <br />FR DR French Door <br />REF or Ref. <br />Refrigerator <br />S5 <br />DETAILS <br />ALT or ALT. Alternate <br />Be Base Cabinet <br />FRT Front <br />FT or Ft. Foot/ Feet <br />REINF <br />READ or Req'd. <br />Reinforcing <br />Required <br />- - <br />SS <br />RETROFIT DETAILS <br />BF Bifoid Door <br />FTG or Ftg. Footing <br />RM or Rm. <br />Room <br />- <br />D1 <br />DETAILS &SECTIONS <br />BK SH or Bk Sh BookShelf <br />BLK or BLK. Block <br />FXD GL Fixed Glass <br />GALV or Galv. Galvanized <br />RND or Rnd. <br />RO or R.O. <br />Round <br />Rough Opening <br />- -- -_ - -- - - - - <br />- <br />- <br />WP <br />WATERPROOFING DETAILS <br />BLW or BLW. Below <br />GC or G.C. General Contractor <br />RS, R/S, RISH or R&S <br />Rod and Shelf <br />-- --- — <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />BM or Bm. Beam <br />BOT or Bot. Bottom <br />GFI or G.F.I. Ground Fault Interrupter <br />GT or G.T. Girder Truss <br />SC <br />SD or SD. <br />Solid Core <br />Smoke Detector <br />- - <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />BP or B.P. Bypass (door) <br />BRG or BRG. Bearing <br />GYP BD or Gyp. Bd. Gypsum Board <br />HB Hose Bibb <br />SGD <br />SH or Sh. <br />Sliding Glass Door <br />Shelves <br />= _- <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />C Carpet <br />HC Hollow Core <br />SHT <br />Sheet <br />- - <br />SH1.0 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CAB Cabinet <br />CIR or Cir. Circle <br />HDR or Hdr. Header <br />HGT or Hgt. Height <br />SHWR or Shwr. <br />SL or S.L. <br />Shower <br />Side Lights <br />- - - <br />SH1.1 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CJ or C/J Control Joint <br />CLG or Clg. Ceiling <br />CMU Concrete Masonry Unit <br />HH or H.H. Hand Held (plumbing faucet) <br />HORIZ Horizontal <br />HS Hard Surface (flooring) <br />SPECS or SPECS. <br />SPF or S.P.F. <br />SQ FT or SF or S.F. <br />Specifications <br />Spruce Pine Fir <br />Square Foot (feet) <br />FF E—J] <br />I� <br />❑ ❑ <br />SH1.2 <br />SH1.3 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COFF or Coff. Coffered or Tray Ceiling <br />COL M Col. Column <br />COMorComm. Community <br />ILO In Lieu Of <br />INS or nt Insul. Insulation <br />INTorint. Interior <br />SQ or Sq. <br />SIN <br />SWorS.W. <br />Square <br />Storage <br />Shear Wall <br />JEl <br />SH1.4 <br />SH1.5 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COMP or Comp. Compressor <br />K/WALL or K/Wall Kneewall <br />SYP or S.Y.P. <br />Southern Yellow Pine <br />CONN or CONN. Connection <br />KS or K.S. Knee Space <br />TB <br />Towel Bar <br />CONT or Cont. Continuous <br />LAUN or Laun. Laundry <br />TEMP or Temp. <br />Tempered <br />[::IEIE:l <br />CSMT Casement <br />LAV or Lay. Lavatory <br />THIKN or Thik'n. <br />Thicken <br />CT or C.T. Ceramic Tile <br />LF or L.F. Linear <br />TOB or T.O.B.op <br />of Block <br />D or D. Dryer <br />LL Lintel Length <br />TOM or T.O.M.O. <br />Top of Masonry <br />❑ a FE7[711E] [7:11 <br />DB Door Bell <br />LT Laundry Tub <br />TOP or T.O.P. <br />Top of Plate <br />DBL or Dbl. Double <br />MAS or Mas. Masonry <br />TP <br />Toilet Paper Holder <br />DCF Decorative Cementitious Finish <br />MAX or Max Maximum <br />TR <br />Towel Ring <br />DEC or Dec. Decorative <br />MC Medicine Cabinet <br />TRANS WDW or Trans. <br />Transom Window <br />DED or Ded. Dedicated (outlet) <br />MFR or Mfr. Manufacturer <br />TYP or Typ. <br />Typical <br />DIA or Dia. Diameter <br />MGT Management (room) <br />UC or u.c. <br />Under Counter <br />DISP or Disp. Disposal <br />MIN or Min Minimum <br />UCL <br />Under Cabinet Lighting <br />DIST or Dist. Distance <br />MIR or Mir. Mirror <br />UNO or U.N.O. <br />Unless Noted Otherwise <br />DMF Decorative Masonry Finish <br />ML or M.L. Microlam <br />V or v. <br />Valve (shower or tub/shower) <br />DS or D.S. Drawer Stack <br />MONO or Mono Monolithic <br />VB <br />Vanity Base <br />DTL Detail <br />MW or MICRO or Micro. Microwave <br />VERT or Vert. <br />Vertical <br />DV or D.V. Dryer Vent <br />NTS or N.T.S. Not to Scale <br />VL or V.L. <br />Versalam <br />DVP or D.V.P. Diverter Valve (plumbing) <br />OE or O.E. Owner's Entry <br />VTR orVTE <br />Vent through Roof / Exterior <br />DW or D.W. Dishwasher <br />EA or Ea. Each <br />ELEC or Elec. Electrical <br />OPNG or Opn'g. Opening <br />OPT or Opt. Optional <br />PC Pull Chain <br />W or w <br />W/orw/ <br />WA or W.A. <br />Washer <br />With <br />Wedge Anchor <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />ELEV or Elev. Elevation <br />PED or Ped. Pedestal <br />WC or W/C or W.C. <br />Water Closet (toilet) <br />EQ Equal <br />PH Phone <br />WO orWd <br />Wood <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />EW or E.W. Each Way <br />PKT or Pkt. Pocket (Door) <br />WDW HDR or WDW. HDR. <br />Window Header <br />FOR 2 STORY HOMES <br />EXP or Exp. Expansion <br />EXTorExt. Exterior <br />PL or P.L. Parallam <br />PLF Pounds per linear foot <br />WH or W.H. <br />WIC or W.I.C. <br />Water Heater <br />Walk-in Closet <br />THIS DRAWING AND DESIGN IS VALID <br />FBC Florida Building Code <br />PLNT SHLF or Plt. Sh. Plant Shelf <br />WM or W.M. <br />Wall Mounted (plumbing fixture) <br />FOR 12 MONTHS AFTER THE DATE IT <br />FDNorFdn. Foundation <br />PLT HT or Plt. Ht. Plate Height <br />WP <br />WaterProof(ing) <br />IS SIGNED AND SEALED OR WHILE <br />FFB Finsh Floor Break <br />PSF Pounds per square foot <br />INS <br />Water Softener <br />CURRENT CODE IS VALID <br />FG Fiberglass (Shower Pan) <br />FIN Finished <br />FIN FLR or FF or Fin. Flr, Finished Floor <br />PT or P.T. Pressure Treated <br />PWorP.W. Pre -wire <br />PWDR or Pwd. Powder Room <br />VWVF <br />Welded Wire Fabric (Mesh) <br />REV. 06.23.22 <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />PLAN <br />REVISIONS <br />DATE VERSION DESCRIPTION <br />Notice to Builder & All Subcontractors <br />08-20-15 1. 0 <br />NEW BASE PLAN <br />of these <br />d is the intent t Designer/Engineer listed to the providing <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />12-8-15 2.0 ADDED VAULT. C LG <br />. <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />12-28-17 3.0 <br />2017 FBC UPDATES <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found these plans should be directed our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />02-21-18 4.0 ADDED GRADE BEAM 150 MPH ENG. <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />08-27-19 4.1 <br />ENG. REVIEW FOR 150-C MPH <br />Payments will be made in accordance to the terms of the <br />agreement. <br />09-20-19 4.2 ADD 8'-8" ELEV. FOR TREVESTA <br />Control of Construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />12-12-19 4.3 <br />ELEV. B EXTEND ENTRY SLAB <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />12-15-20 4.4 <br />OVERHANG OVER SGD REV. TO <br />3' PER C.M. <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />Ism <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />12-19-20 5.0 <br />FBC 2020 CODE UPDATE <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />06-14-21 5.1 <br />H VAC DOOR TO 2652 PER C.M. <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />any such peril at any time for any reason. <br />11-29-21 6.0 <br />ADDED ELEV KL M PER <br />C.M.against <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />1941 A1.1KLM <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. <br />I <br />CNN <br />Ca _ <br />r <br />Il S <br />C Cc C.) N <br />- v m x <br />LA- �. <br />N <br />N t <br />N O <br />d <br />Q N Y <br />3 CL <br />cL) <br />3 d <br />r <br />d <br />o��•�°', <br />N <br />H a� <br />o) <br />E <br />a <br />N <br />' <br />Q <br />a <br />Q <br />„V <br />`Tf <br />M <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />fn <br />a <br />E <br />co <br />G <br />N OI oo <br />N n <br />7 <br />N � ik LL <br />C U L LL W <br />LL LL <br />V <br />13,Q�r <br />Z <br />J d <br />cc C a <br />t y o <br />o <br />Z <br />IL <br />J <br />LO MZ ¢ k <br />ZN <br />o cQi <br />W <br />❑ ❑ <br />" M <br />z "M <br />O <br />z � � <br />z <br />Q <br />J — <br />d N <br />N <br />s <br />zC1 <br />(D(a(a <br />j� <br />U <br />� <br />w <br />O <br />N <br />V/N <br />W—C' <br />� .U) <br />U) <br />U W <br />eop <br />L V <br />_ � d <br />U o' y <br />c N <br />N <br />• <br />Of <br />0 <br />� <br />w <br />M <br />J <br />ZO <br />Z <br />IL <br />E <br />z o <br />Z <br />Z0o <br />E U <br />Z® <br />oa <br />H M <br />O E <br />0 <br />20 <br />UO <br />a F <br />O <br />p <br />Z <br />� <br />az <br />wZ <br />cn <br />0a <br />OU <br />0 � <br />ZF <br />Z� <br />m J <br />aw <br />W <br />C, � <br />O <br />OLL <br /><O <br />�U <br />aw <br />3 <br />¢ <br />zId <br />0 3 <br />0o <br />= <br />> <br />J <br />LOfT <br />m <br />Q <br />0 <br />nU')' <br />J <br />J LO <br />LO <br />Y <br />LO <br />� <br />� <br />r <br />U <br />U) 0N <br />M <br />m <br />L <br />L <br />N <br />O+ <br />T <br />QI <br />p <br />� <br />N <br />oo <br />O <br />r <br />.0 <br />LL- CV <br />c0 <br />V/ <br />LO <br />� <br />Q <br />� <br />r <br />E <br />c <br />(0 T <br />M <br />o <br />Z <br />l0 <br />Z <br />c <br />7 <br />E O <br />N <br />cn <br />N <br />c <br />a <br />U -i <br />Q p <br />JOB <br />NO: <br />23-00526 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />C S <br />S <br />1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.