My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36485 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36485 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 6:13:46 PM
Creation date
2/28/2025 11:08:14 AM
Metadata
Fields
Template:
Building Plans
Street #
36485
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6619
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9 u l I r I 1_ 'I. I �� <br />W <br />z <br />N <br />v <br />_ <br />Cn <br />0 <br />J <br />0 <br />I <br />N <br />i <br />O <br />kn <br />O <br />CD <br />a <br />rM <br />a <br />E <br />9 <br />E <br />x <br />v <br />c <br />J <br />i <br />a <br />0 <br />v <br />tZ <br />N <br />0 <br />c <br />0 <br />a <br />N <br />N <br />ai <br />0 <br />0 <br />0 <br />THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METALLATH <br />16GAx1-1\2" LONG (3/4"-1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />16GAx1-1/2" LONG (3/4"-1" <br />CROWN) STAPLES @ 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF U <br />HOME H C G <br />GARAGE SIDE 0 0 0 <br />5'-011 Q - <br />0 <br />STUB -OUT FOR 1'-011 0 9 <br />10 <br />GAS METER O o <br />� U <br />N = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />1) SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-01, <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />FT_0ENAILCONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood anels or 2 x — <br />P <br />1-1 /8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x — lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />FILL CELL STD. 90' HOOK BOND BEAM <br />w <br />a STD. 90° CONT. #5 <br />BAR CONT. #5 I HOOK BAR <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />5/8"0 <br />#5 CONT. THRU <br />FROM BOLT <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />� � <br />SEE PLAN FOR REQ'D <br />� <br />� PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />- Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. ) Small gap 2" min. <br />r 2" max. 4" max — <br />. <br />Clinch nails -� <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit i I <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/PlywoodlOSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVINGY"GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />code for appropriate <br />1/16 <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />I Isa 3" 110d1 nails at 6" n c <br />Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />"' MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series De th End Intermediate <br />- - - <br />BCI5000s <br />9-1/2" 2-8d <br />11-7/8"I 2-8d <br />28d___ <br />'-- 3-8d <br />14" 2-8d <br />BCI 6000s® <br />BCI6500A <br />9-1/2" <br />11-7/8" <br />14 <br />2-8d <br />2-8d <br />2-8d <br />_ 2-8d <br />3-8d <br />I 5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />2-8d <br />6-8d <br />_ <br />BCI90s®' <br />_16" <br />11-7/ " <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over _ <br />blocking and wall or beam below.* — -� <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at Vo.c. for all joist <br />blocking panel "Non -stacking walls <br />require additional consideration.— <br />�7-7,7-3 <br />■7.7 <br />611 A 1 2' ROUND HOLE MAY 611 611 DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y2' <br />THE WEB. PROVIDE AT of ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS, <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2' <br />v <br />.. <br />_ s <br />LLL <br />-M <br />a <br />Any 16" joist <br />Span (8) <br />8 <br />T- 0" <br />V-1" <br />1' 2" <br />1'-2" <br />1'-3' <br />V-3" <br />1'-T' <br />T-11 " <br />24' <br />2-9' <br />32" <br />3 -7' <br />12 <br />1' 0' <br />T-1" <br />1' 2" <br />1 _2" <br />V-3" <br />T-9" <br />2'-4" <br />2-11 " <br />37' <br />4!-Z' <br />41-9. <br />6-4' <br />16 <br />1' i0 <br />1'-1" <br />1' 2" <br />1 21. <br />1'-T' <br />2-9.3-2" <br />3-10" <br />4-9" <br />5 7 <br />6-4' <br />72" <br />20 <br />1'-0" <br />1'-i"' <br />1' 2" <br />1 2'. <br />2z" <br />3-0 <br />4'-0 <br />4'-10" <br />5'-11" <br />5-11" <br />T-11" <br />8'-111, <br />24 <br />T-O <br />T-1" <br />V-2 <br />V-3" <br />2� <br />3'-T' <br />4'-9" <br />5'-10" <br />T2" <br />81-41 <br />9- <br />10'_9' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Joist hanger <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) I I <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM ° <br />.. <br />SEE PLAN FOR - <br />FOUNDATION INFO <br />STEM FOUNDATION <br />\ \\\\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />�- 1/4"-2" gapes <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />-�� requirements <br />0.6 X Joist <br />p ��depth <br />I'I I I <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />• a. <br />r-- REINF. SEE PLAN <br />/A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />s 1 <br />SIMPSON H10A (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />I HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />1"111"1!� \ A 1 TI IP\1 1 rA IP1 <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />FF <br />d v ° °a n °a L <br />a <br />II: ICI—III-1 <br />—I I � 1 I I= a ° <br />—III— <br />Q <br />SEE FND. PLN. <br />SIZE & REINF. <br />as <br />N <br />0 <br />N <br />c <br />0; <br />-oCM <br />W <br />ELo <br />_J <br />a- � o <br />C � V <br />i N _ CM <br />LL- <br />... c a <br />to O <br />VI lV t <br />N O � <br />d <br />dY <br />m <br />Cc', a <br />x3 m <br />W <br />i C G <br />c E <br />�o 0 <br />a <br />I <br />,��leo{iEli{ffttPtFjr� <br />0 � gR° Wti <br />.. <br />�. .• � .fie <br />G Z:`� <br />C;G o `w_ <br />• <br />'� <br />ref\ �•` <br />A <br />•j <br />zz <br />!_ 0 ' <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />E $ uN} <br />4 p g 8 N '� <br />N N C. <br />c:, a i� J <br />0 <br />N <br />C14 0 1 LL a a <br />N <br />a mLLU_ a <br />C� <br />Z <br />13 <br />_ L:°� p o <br />Z m crn 0 � <br />G <br />Z <br />W OD 0 <br />Z rn �ZIL <br />N �� <br />< <br />OULL ❑❑❑ <br />Z <br />W <br />0 <br />z QTN 8 <br />z <br />Q <br />d � <br />N <br />N z <br />C9 0 <br />.2 <br />LL <br />4-1 C-n(D <br />U <br />O IrI o <br />N Ly N <br />�N CB <br />CB <br />U <br />W <br />J <br />1--- — E <br />L <br />not <br />I <br />1 <br />U <br />� <br />• <br />8 <br />S� <br />o <br />w <br />Z <br />M <br />J <br />0 � <br />Q <br />LL <br />0 <br />Z. <br />f p <br />>m <br />6 N <br />Q <br />d <br />E <br />N C) <br />❑LL <br />z® <br />❑a <br />H c6 <br />o <br />f <br />< <br />w� <br />U o <br />01 <br />Z�� <br />GO <br />S Z <br />wz <br />ym U <br />mo <br />O <br />ZF <br />zW <br />m <br />� J <br />< <br />$ <br />o< <br />5z <br />�w <br />WC- <br />o <br />m <br />w0 <br />�� <br />o <br />w` <br />�5 <br />;o <br />M <br />v <br />M <br />tl r <br />0O3 <br />�� <br />O <br />>L6 <br />O <br />m <br />0 <br />L <br />CU <br />T <br />LO <br />T A <br />co <br />LO <br />3:L0 <br />- <br />O a <br />o <br />co <br />Lo <br />LO <br />001.0 N <br />T <br />T <br />Q <br />4i <br />T <br />ClO <br />M M <br />o <br />W <br />7 (0 Hi LO <br />Z <br />z <br />E V— y <br />E ca <br />m <br />a <br />v <br />c0 0 Q o <br />0) <br />0) <br />JOB <br />NO : 23-06115 <br />SCALE : AS NOTED <br />SHEET NO. <br />SIN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.