Street #
36485
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6619
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />I to lights & outlets <br />? to appliances and GFI <br />) to WH <br />to Range <br />to HVAC <br />MAIN 114. <br />150=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished flcen oor to ter line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />F�Fw.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j WALL SWITCH <br />$3 THREE-WAY SWITCH <br />94 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />OCEILING MOUNTED LIGHT FIXTURE <br />FO HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />Q EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />DB PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />N❑ 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />C� J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />J OPT. CEILING FAN <br />w (1) PHONE LINE, (1) DATA PORT <br />) <br />III- 1.5" VTR <br />'I <br />I <br />I <br />I <br />� I <br />I <br /><\ I I <br />I I <br />I I I I <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />H FOR DISPOSAL <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD kGFPER SPECS <br />I I � <br />II � <br />If <br />II <br />II <br />II <br />Il <br />OPTIONAL LIGHTING <br />SCALE: %4'=1'-0" <br />I W TT n <br />S.D <br />I j \ <br />-------- <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ 1 <br />I I LIGHT PRE -WIRE <br />I I <br />BEDROOM 2 ' <br />I I <br />I I <br />I I I <br />L------------ -I <br />dhP <br />I I <br />I <br />I <br />I I <br />I 1 <br />I <br />I 1 <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L---------------------------------------j <br />■'■ ■'■ <br />LANAI <br />ROUGH -IN FOFk <br />AC PAD I OPT. CLG. FA WP 'I/ <br />GFI I WP G LIGHT PRE-W E <br />DISC. GFI ' <br />I <br />DINING NOOK <br />r - <br />PENDPT PER SPEC <br />_ GFI_ <br />r-------- <br />■ / I GFI I o I SWITCH FOR <br />� I a I DISPOSAL IN <br />FAMILY L---� I CABINET <br />IGFI <br />5'-8" CH GFII ; I ■ <br />i I <br />9 I 5'-8" T-1 "I <br />------ -- co 'GFI <br />v I <br />ROUGH -IN FOR I EH ( I KITCHEN / I <br />OPT. CLG. FAN/ DEDICATED I <br />LIGHT PRE -WIRE I RECEPTACLE Q I - r^===,i <br />/ FOR MICROWAVE j � `ALT <br />� <br />■ RANGE HOOD GFI( r 3 I I AC PAD I I <br />PER SPECS ■ 1 <br />I I 3 <br />WP <br />GFI <br />/ II O DISC. <br />■ O ■ <br />M LI I I I l I t I I I <br />TO LI HTS T D . <br />OPEN I I I I I I I I <br />TO ABV. I I I AND SWITCH __ ----- I I I IABI I I I I I I I I I I I I ■ <br />FOYER GFI _ <br />@ 44" LU ~ <br />A.F.F. / I W.H. W z <br />-� / f J r- W <br />LULL Q 2 <br />■■ ■■ �/� / Oa W0 <br />• / U J <br />IDB / ° U <br />' ` J <br />I I):�PC _ _ '! I GARAGE L U <br />- L-------- LIGHT AS > w <br />(ENTRY LIGdT PER SPECS o <br />■ AS PER SYECS - `a <br />/ GARAGE DOOR <br />■ GFI ■ <br />� <br />r------------ -- ------ <br />------1 9 I GARAGE I <br />I I I <br />I I <br />1 j Q IRRIGATION1 <br />GFI @ 44"1 <br />A.F.F 1 <br />I I <br />I I <br />I I <br />■ ■-------------------- 7�'■ <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS / <br />ELECTRICAL PLANS. <br />C" <br />!V <br />O <br />C%A <br />ilk <br />o .= <br />CD <br />'Ci <br />o LW <br />o <br />CM <br />�! <br />_ m K <br />a U. 1 <br />N tv o <br />y N O to <br />d <br />�.c o <br />as o a <br />cc y d a <br />C d o <br />to 0 <br />a w <br />0 <br />M <br />N <br />0 <br />N <br />M <br />LO <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />um <br />W <br />Q <br />O <br />vE <br />M 8 <br />N_ <br />A <br />J <br />0'-' <br />y <br />L'0' <br />U)N <br />5=3 <br />� -C <br />4 <br />N <br />@LLLLaYc� <br />0' ' d a <br />_ z <br />0 <br />z <br />�i <br />COS <br />r <br />O m <br />N <br />og-� <br />to <br />N J <br />¢ m <br />rn°. <br />W <br />LL <br />ILW <br />Jr-w <br />ch Z CD <br />a04 <br />.= <br />I=— <br />OU ❑❑❑ <br />W <br />z <br />(D <br />z <br />N <br />w <br />U <br />0 <br />V) <br />�V) <br />Of <br />w <br />c6 <br />t- <br />U <br />W <br />J <br />Rig <br />f— <br />= <br />— E <br />� o <br />U <br />z9,� . <br />i. <br />c <br />c <br />U) <br />N to <br />I� <br />o <br />M <br />� � <br />r <br />z <br />Z <br />J <br />N� <br />a <br />o <br />I— <br />� <br />0. <br />�O <br />�Z <br />Z <br /><~ <br />w= <br />wz <br />,..O. i <br />o0 <br />¢ `J <br />N <br />¢z <br />a°z <br />w <br />m0 <br />Z' <br />Z <br />m v <br />J <br />�� <br />m <br />¢ w <br />¢ a <br />0� <br />Z Z <br />g0 <br />Wco <br />A <br />m <br />o LL <br />z <br />N � <br />oz <br />i3 <br />2�. <br />o <br />wa <br />;o <br />a� <br />lu <br />z¢ <br />r <br />O— <br />Ed <br />U� <br />E2 0 <br />Q: <br />L6 <br />O <br />m <br />m <br />O <br />QL� <br />— <br />ICU <br />T <br />Ln <br />L.n <br />Q <br />= T— <br />y, <br />co <br />T <br />N <br />a <br />m <br />Ln <br />O <br />= <br />O <br />3:coLn <br />N <br />LO <br />CD <br />N <br />T <br />T <br />E <br />M <br />M <br />to <br />o <br />? <br />z <br />E <br />m <br />C <br />a <br />E <br />J <br />a <br />Q <br />hi0) <br />p <br />JOB <br />NO: <br />23-06115 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />