Laserfiche WebLink
PRODUCT APPROVAL SPECIFICATION SHEET(2024) <br />As required by Florida Statute 553.842 and Florida Administrative Code 913-72, please provide the information and approval numbers on the building components listed below if <br />they will be utilized on the construction project for which you are applying for a <br />Cate o /S ubcategory <br />Manufacturer <br />Product Description <br />Approval Numbers <br />Test Pressures <br />Ex .Date <br />1. EXTERIOR DOORS <br />A. SWINGING <br />ThermaTru <br />Fiber -Classic and Smooth -Star (NON -IMPACT) <br />FL20461.1 <br />+67.0/-67.0 psf <br />12/31/2026 <br />ThermaTru <br />Fiber -Classic and Smooth -Star (IMPACT) <br />FL20468 <br />+67.0/fi7.0 psf <br />12/31/2026 <br />ThermaTru <br />Fiber -Classic and Smooth -Star (IMPACT) <br />FL20470 <br />+80.0/-80.0 psf <br />12/31/2026 <br />B. SLIDING <br />MI Windows and Doors <br />Series 420 <br />FL15332.1 - FL15332.5 <br />+40.0/40.0 psf <br />12131/2024 <br />PGT <br />Series 5570 <br />FL242.6 <br />+60.0/-60.0 psf <br />8/4/2026 <br />Pella Corporation <br />Standard Performance Sliding Patio Door <br />FL1824 <br />+40.0/-40.0 psf <br />2/16/2032 <br />C. SECTIONAL <br />Wayne -Dalton <br />Series 8000/8100/8200 #1105 (8X7) <br />FL8248.3 <br />+31.0/-35.0 psf <br />12/31/2035 <br />Wayne -Dalton <br />Series 8000/8100/8200 #1123 (16X7) <br />FL8248.10 <br />+30.0/-33.5 psf <br />12/31/2035 <br />Wayne -Dalton <br />Series 8000/8100/8200 #1124 (16X7) <br />FL8248.11 <br />+34.4/-38.3 psf <br />12/31/2035 <br />D. METAL LOUVERED DRS <br />Curries Division of AADG, Inc <br />607,707,727,747,and 847 Single & Pairs of Doors <br />FL11537.1 <br />N/A (see inst sht) <br />12/31/2025 <br />2. WINDOWS <br />A. SINGLE HUNG <br />MI Windows and Doors <br />3540 Single Hung <br />FL17676.11 <br />+30.0/-30.0 psf <br />4/12/2027 <br />MI Windows and Doors <br />3540 Series Fixed Glass <br />FL17845.1 <br />+35.01-50.0 psf <br />4/12/2027 <br />MI Windows and Doors <br />1620 Series Single Hung Non -Impact <br />FL21637.4 <br />+35.0/-47.0 psf <br />8/1/2027 <br />MI Windows and Doors <br />1620 Series Single Hung Impact <br />FL21637.8 <br />+35.0/-47.0 psf <br />8128/2027 <br />MI Windows and Doors <br />1620 Series Fixed Non -Impact <br />FL21639.1 <br />+55.0/-55.0 psf <br />8/17/2026 <br />MI Windows and Doors <br />1620 Series Fixed Impact <br />FL21639.6 <br />+55.0/-55.0 psf <br />8/15/2026 <br />PGT <br />Series 5500 <br />FL239.2 <br />N/A <br />7/30/2025 <br />Pella Corporation <br />Series 10/20 <br />FL11206 <br />+35.0/-35.0 psf <br />6/17/2027 <br />B. HORIZONTAL SLIDER <br />MI Windows and Doors <br />Series 188 <br />FL15351.1 <br />+55.01-55.0 psf <br />12/31/2035 <br />Pella Corporation <br />Series 10/20 <br />FL11161 <br />+30.0/-30.0 psf <br />7/27/2024 <br />Pella Corporation <br />Series 10 Sliding Window <br />FL12811 <br />N/A <br />5/25/2031 <br />C. FIXED <br />MI Windows and Doors <br />Series 3500 HP PW <br />FL17845.5 <br />+70.0/-75.0 psf <br />4/30/2026 <br />PGT <br />Series 5520 <br />FL243.5 <br />N/A <br />4/30/2025 <br />Pella Corporation <br />Series 10/20 <br />FL6694 <br />+50.0/-50.0 psf <br />7/15/2024 <br />Pella Corporation <br />10 Series Flange Fixed <br />FL16280 <br />N/A <br />5/25/2031 <br />D. MULLION <br />MI Windows and Doors <br />Series 5764 <br />FL15353.2 <br />N/A <br />12131/2024 <br />PGT <br />Series 5500 <br />FL261.1 <br />N/A <br />5/26/2026 <br />E. OTHER <br />3. PANEL WALL <br />A. SIDING <br />James Hardie Building Prod. <br />Cemplank Lap Siding and HardiePlank Lap Siding <br />FL13192.1 - FL13192.2 <br />N/A <br />3/31/2026 <br />B. SOFFITS <br />Alside <br />Solid and Vented Vinyl Soffit <br />FL15272.1 - FL15272.2 <br />+75.0/-75.0 psf <br />12/31/2026 <br />Alpha Aluminum, Inc. <br />Solid and Vented Aluminum Soffit <br />FL16544 R5 <br />+54.2/-54.2 psf <br />7/30/2033 <br />C. OTHER <br />4, ROOFING PRODUCTS <br />A. ASPHALT SHINGLES <br />GAF <br />3 Tab, Dimensional <br />FL10124.1 <br />N/A <br />1211612025 <br />B. UNDERLAYMENTS <br />Tamko (for Shingle Root) <br />151b Felt Underiayment <br />FL12328 <br />N/A <br />6/1/2026 <br />Plyglass USA, Inc. (for Tile Roof) <br />POLYSTICK TU MAX <br />FL5259 <br />N/A <br />12/4/2026 <br />C. ROOFING FASTENERS <br />NOT USED <br />D. ROOF VENTILATORS <br />Thompson Arch Metal Comp. <br />Off Ridge Vents <br />FL16918.1 - FL16918.4 <br />N/A <br />9/9/2026 <br />Florida Metal Products, Inc <br />Vent RV10 <br />FL21580.3 <br />N/A <br />12/31/2024 <br />Lomanco, Inc <br />DA4 Exahust Vent <br />FL17202.1 <br />+97.5l-97.5 psf <br />12110/2025 <br />E. ROOFING TILES <br />Boral Tile <br />Villa 900 <br />FL7849.27 - FL7849.28 <br />N/A <br />12/31/2025 <br />Boral Tile <br />Saxony 900 <br />FL7849.16 - FL7849.20 <br />N/A <br />12/31/2025 <br />F. METAL ROOF <br />Drexel Metals, Inc. <br />DMC 100NS, DMC 150SS, DMC 1755, DMC <br />2005, DMC 5V <br />FL17679.1 <br />+0/-180 <br />12/31/2025 <br />April 12, 2024 <br />PRODUCT APPROVAL SPECIFICATION SHEET(2024) <br />As required by Florida Statute 553.842 and Florida Administrative Code 913-72, please provide the information and approval numbers on the building components listed below if <br />they will be utilized on the construction project for which you are applying for a <br />Cate o /S ubcategory <br />Manufacturer <br />Product Description <br />Approval Numbers <br />Test Pressures <br />Exp. Date <br />5. SHUTTERS <br />A. STORM PANELS <br />Global Protection Products <br />Galvanized Steel Storm Panels <br />FL15076.1 - FL15076.2 <br />N/A <br />12/31/2024 <br />All American Shutters & Glass <br />Galvanized Steel Storm Panels <br />FL17869.1 <br />N/A <br />12131/2024 <br />6. STRUCTURAL <br />COMPONENTS <br />A. WOOD <br />CONNECTORS/ANCHORS <br />Simpson Strong -Tie <br />Titen Stainless Steel Concrete & Masonry Screw <br />(TTN-SS) <br />FL2355 <br />N/A <br />12131/2024 <br />Connector Screws <br />FL9589 <br />N/A <br />12/31/2026 <br />Take -Up Devices <br />FL10007 <br />N/A <br />12131/2026 <br />Hold-downs <br />FL10441 <br />N/A <br />12/31/2026 <br />Accents Angles <br />FL10446 <br />N/A <br />12131/2026 <br />Hip Ridge Connectors <br />FL10447 <br />N/A <br />12131/2026 <br />Coiled Straps <br />FL10456 <br />N/A <br />12/31/2026 <br />Face -mount hangers <br />FL10531 <br />N/A <br />12/31/2026 <br />Top flange hangers <br />FL10667 <br />N/A <br />12131/2026 <br />Adjustable Post Base <br />FL10860 <br />NIA <br />12/31/2026 <br />Bearing Plate <br />FL10866 <br />N/A <br />12/31/2026 <br />Joist Hanger <br />FL11468 <br />N/A <br />12/31/2024 <br />Truss Anchor <br />FL11473 <br />N/A <br />12/31/2024 <br />Tension Tie <br />FL11496 <br />N/A <br />12/31/2026 <br />Anchor Bolts <br />FL13628 <br />N/A <br />12/3112026 <br />Straps <br />FL13872 <br />N/A <br />12131/2026 <br />Masonry Beam Hangers <br />FL13904 <br />N/A <br />12/31/2024 <br />Strong -Drive SDWC Screw <br />FL13975 <br />N/A <br />12/31/2026 <br />Truss Plate <br />FL15363 <br />N/A <br />12/31/2026 <br />Adhesive Anchor for concrete <br />FL15730 <br />N/A <br />12/31/2026 <br />Adhesive for masonry <br />FL16230 <br />N/A <br />12/31/2026 <br />Tapping Screws <br />FL16937 <br />N/A <br />12/31/2026 <br />Bypass Framing Connector <br />FL35320 <br />N/A <br />12131/2026 <br />B. TRUSS PLATES <br />ITW Building Components <br />Alpine Truss Plates <br />FL1999.1 - FL1999.4 <br />N/A <br />12/31/2024 <br />MiTek Industries, Inc. <br />Truss Plates <br />FL2197.1 - FL2197.5 <br />N/A <br />12/31/2024 <br />C. ENGINEERED LUMBER <br />Weyerhaeuser <br />Rim Board, LVL, PSL, LSL <br />FL6527.1 - FL6527.5 <br />N/A <br />3/31/2025 <br />D. MATERIAL <br />Cast -Crete Corp. <br />High Strength Concrete Lintels <br />FL158 <br />N/A <br />5/21/2027 <br />Commercial Concrete Products, Inc. <br />High Strength Concrete Lintels <br />FL1774 <br />NIA <br />1/26/2034 <br />The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be <br />available to the inspector on the jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy <br />of the applicable manufacturers installation requirements. Further, I understand these products may have to be removed if approval cannot be demonstrated during inspection. <br />APPLICANT SIGNATURE <br />DATE <br />N <br />a) <br />(n <br />O <br />U <br />C <br />O <br />O <br />C <br />.� <br />Ca <br />- <br />CU <br />U <br />o <br />ca <br />M <br />c <br />o <br />0 <br />t- <br />ca <br />o <br />CU <br />E <br />o <br />o <br />a� <br />Cn <br />a <br />z <br />Z <br />W <br />J <br />L <br />(D <br />Z <br />,,,,,cET NO. <br />PA 1.0 <br />