Laserfiche WebLink
to <br />3 <br />v <br />c.i <br />s <br />3 <br />I <br />x <br />rn <br />L0 <br />ID <br />v <br />0- <br />0 <br />C7 <br />J <br />0 <br />I <br />U <br />tz <br />to <br />to <br />L <br />00 <br />C7 <br />co <br />I <br />N <br />t[ <br />O <br />7 <br />N <br />0 <br />3 <br />CI <br />a <br />N <br />v <br />a <br />d <br />O <br />`o <br />c <br />y <br />U <br />C> <br />i <br />0 <br />0 <br />J <br />m <br />L�. <br />N <br />N <br />S <br />0 <br />0 <br />a <br />N <br />N <br />S <br />0 <br />0 <br />U <br />Z <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />LIL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />Q, <br />EXHAUST FAN/LIGHT COMBINATION <br />® D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�]M <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />J <br />DISCONNECT SWITCH <br />&�3 <br />ROUGH -IN FOR OPT. CEILING FAN <br />q��Z <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />A9 <br />(1) PHONE LINE, (1) DATA PORT <br />150AI200A INDOOR <br />PANEL CENTER <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />A14 to lights 8 outlets <br />912 to appliances and GFI <br />k10 to WH <br />k8 to Range <br />66 to HVAC <br />MAIN t <br />Or2oo=4'10 <br />50=20 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />l" <br />G <br />CAFE <br />1 <br />vll 2't <br />Ad ETA <br />PLUMBING RISER_ <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />OWNER'S SW� ITE <br />T <br />/ ROUGH -IN FOR / <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />/ I O. BATH <br />FAMILY RM <br />1 / <br />I G � <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />U.C. OUTLET <br />FOR DW <br />Cn <br />U.C. OUTLET <br />I <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />15' <br />VERIF METER <br />LOCATION WITH <br />BUILDER WP H.B. <br />r ---- I A GFI <br />' IRRIGATION <br />----�1 <br />_ <br />VERIFY LOCATION GFI @ 44" A.F.F. <br />W.H. <br />ELECTRICAL PANEL <br />I <br />0 <br />I <br />I <br />W.I.C. <br />I <br />I <br />I <br />\ <br />2 CAR GARAGE <br />I <br />I <br />I <br />I <br />GFI FOR <br />GAR. DOO� <br />GFI I <br />GFI @ 44" <br />A.F.F. <br />-----------J <br />_ <br />I <br />OPT. <br />D. <br />GFI <br />L U <br />AHU <br />I <br />GFI @ 44" <br />A.F.F. <br />I I <br />I <br />\ OPT. 4 <br />GFI REF, <br />GFI L---------- GFI <br />D.W. I <br />SINK w/ DISP <br />— K I TC H E N U.C. SWITCH <br />FOR DISPOSAL <br />PENDANT AS \ <br />PER SPECS \ _ — <br />� RANGE <br />in \ M <br />i <br />. 3 GFI : GFI <br />i <br />DEDICATED RECEPTACLE <br />H.B. FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />I <br />GFI <br />f= <br />I <br />I <br />BEDROOM 2 <br />ROUGH -IN FOR C �/ <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED <br />/ <br />FOYER,' <br />NTRY <br />I <br />WP j <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />C" <br />C9 <br />U <br />Uj <br />. <br />CL O <br />3RU�� <br />Q -0 CO X <br />� L <br />® <br />N U �� r <br />Q <br />u .c <br />U <br />(3) 0) <br />LY c F <br />ro o <br />a <br />v <br />N <br />0 <br />N <br />N <br />co <br />0 <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />a <br />C <br />. N O N ci Co <br />N_ <br />V <br />N � <br />i! <br />Lu <br />�2s <br />N <br />Q <br />rNi v LL a <br />ro -J LL 2 0. Y 0 <br />U- 55 z <br />J <br />Z <br />=@�_ 0o <br />�ro = o <br />W <br />7 f6 (N m J Q <br />o <br />IL <br />to NZ UO = <br />M <br />0 <br />= <br />N Q U Go H <br />OU ❑❑❑ <br />W <br />V M <br />_ o <br />Z N <br />z � � <br />Q <br />CN <br />N <br />z <br />0 <br />� <br />o <br />u- <br />(� <br />C 7 <br />w <br />Z <br />'ram • <br />V <br />0 w o <br />v) C N <br />Y <br />I =DWalk <br />v c <br />w m <br />L 8 <br />I <br />v o <br />c rn <br />Q 0 <br />s Q <br />N <br />M <br />M <br />J <br />w q <br />0 S2 <br />Z <br />Z <br />4 <br />E <br />W <br />E <br />z <br />�= <br />20 <br />Q� <br />w <br />oa <br />�� <br />o <br />aaZ <br />�o <br />Z <br />t <br />ao <br />wo <br />�Z <br />�w <br />n' <br />c <br />C <br />o� <br />Z <br />J <br />2Z <br />` ° <br />Z Z <br />o <br />3 <br />Q � <br />W <br />in <br />o <br />Q <br />w� <br />8 <br />az <br />H <br />w <br />3 <br />-0 <br />M <br />0 <br />a <br />v <br />old <br />� 3 <br />y O <br />Lnrn <br />L) <br />Q <br />c� <br />F— <br />00 <br />O <br />T <br />O <br />r <br />VJ <br />m <br />m <br />QI <br />O <br />N <br />o <br />O <br />N <br />n <br />LC) <br />T <br />Q <br />CO <br />T <br />E <br />o <br />z <br />:300 <br />r <br />to <br />ccC6 <br />a <br />E <br />U <br />¢ p <br />JOB <br />NO: <br />22-04746 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />