Laserfiche WebLink
^' ^ "" WEATHER <br />✓E BARRIER & <br />MRILY SECURE <br />WEATHER <br />`RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weat <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING -� <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />NAILING FLANGE <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHING. - <br />SHEATHING BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOK <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />- 3/4"A" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1"BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />1 <br />2 SEAL TOPS OF JOISTS <br />8 UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />8 2 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />O <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />NEEDED IN CORNERS RUBBERIZED ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />FLASHING SELF -ADHERED FLASHING <br />SCORED <br />RELEASE PAPER <br />�v (BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />1 <br />Water Resistant Barrier <br />Lath <br />SELF FLASHING <br />-ADHERED <br />Sheathing <br />g <br />5 <br />v <br />Stucco <br />° A ° <br />NS <br />ANC <br />.I <br />DOUBLE <br />ix �6 <br />A d <br />n <br />JOIST <br />, - <br />a d <br />rn <br />SINGLE WOOD <br />BEAM <br />JOIST BELOW- <br />- 1 SELF -ADHERED FLASHING <br />Foundation Wall e <br />SELF -ADHERED FLASHING <br />e <br />3"MIN <br />" <br />SELF -ADHERED SELF -ADHERED <br />4 <br />FLASHING FLASHING <br />O <br />5 <br />SELF -ADHERED FLASHING <br />' <br />SELF -ADHERED FLASHING , • <br />FOUNDATION WEEP SCREED <br />• <br />DECK JOIST <br />OUTSIDE CORNER • <br />-�+ <br />STRIP OF SAF <br />LEGEND <br />SELF ADHERED FLASHING (SAF) <br />o <br />DRAINAGE PLANE WRB <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />as <br />BARRIER (WRB) <br />- - <br />./ <br />BOND BREAK WRB <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />- <br />� <br />i ! <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />c <br />SF LATH <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS <br />v <br />WRAP DP WRB ONTO <br />� <br />THE VERTICAL <br />SURFACE TO TOP OF <br />3 <br />FLANGE AS AN AIR <br />BARRIER <br />rn <br />I I I <br />3-1/2" INCH FLANGE <br />a <br />as <br />CD <br />N <br />n <br />NOT USED <br />.aa <br />PLASTER STOP - <br />CONTINUOUS BACKER - <br />ROD & SEALANT <br />A <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8 <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />31/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as #Oin each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to comer <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />,I I Cement installed over the top of the weep screed. <br />Plaster <br />A over block <br />TACKER ROD 1 st floor <br />FINISH <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />With ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />O n <br />r; O <br />rn <br />Z <br />z <br />Z <br />Q <br />a <br />N C9 <br />co <br />w <br />CD� <br />(z o <br />.0 <br />W <br />�Ln <br />r ~ <br />ru U <br />M <br />oo " <br />Ll l <br />4) M M <br />_ � <br />U <br />r.1 <br />N <br />15 LLB <br />05 tL <br />Q rn <br />Lo Q v <br />Q� Ci <br />B D <br />N N <br />� Val N <br />rn2W 00 <br />) r� z <br />�Zyy <br />UJ <br />LU < <br />Q Z C y¢ p <br />Zcc �r <br />um In N¢o2 �i <br />o <br />(..3 U [- <br />WWW.FDSENG.COM ❑ Ii <br />rn <br />0 <br />N <br />co <br />N <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />0 <br />W <br />ZZ p�, <br />w Za °00 <br />U <br />Z U O <br />Z UJ <br />2 <br />�sZ <br />W <br />6. <br />OU <br />J <br />N <br />L <br />Q� <br />> <br />LU <br />Z <br />LL <br />O <br />OU <br />-a0.o <br />_ <br />�/ <br />r'I <br />9 <br />O0,o <br />0 <br />J <br />� <br />LLl <br />r- � Q <br />W m <br />< <br />O <br />Q � W <br />Z0*11 <br />J <br />Ln <br />di <br />&�j <br />rll <br />tll <br />Q <br />z� <br />U <br />F I- <br />Itn <br />Z <br />t <br />= <br />-{S <br />a <br />O <br />On <br />� <br />J <br />X <br />SCALE : AS NOTED <br />DATE : 5/7/2019 <br />TECH: FFLORES <br />VERSION NO. 4n0 <br />SHEET NO. <br />W P <br />