Laserfiche WebLink
0 PNL-A- <br />208Y/1 20V 30 4W <br />FED FROM MDP <br />11)179 AFC <br />0 0 <br />,,,—%6'0 PRE -DRILLED HOLES. SECURE TO PANEL <br />WITH Y" 0 SS RIVETS (TYP. 4) <br />�—EQUIPMENT NAME AS SPECIFIED ON PLANS <br />SYSTEM VOLTAGE <br />--UPSTREAM EQUIPMENT SUPPLYING POWER <br />AVAILABLE FAULT CURRENT AT EQUIPMENT <br />DATE OF FAULT CURRENT CALCULATUION <br />NSTALL LABEL AT TOP OF ENCLOSURE <br />NOTES: <br />1. ALL DISTRIBUTION EQUIPMENT SUCH AS PANELBOARDS, SWITCHBOARDS, DISCONNECTS, TRANSFORMERS, ETC. SHALL BE <br />PROVIDED WITH AN EQUIPMENT LABEL PER THE REQUIREMENTS OF THIS DETAIL. <br />2. LABELS SHALL BE 2-PLY ENGRAVED PLASTIC LAMINATE WITH BLACK TYPEFACE LETTERS., LABEL BACKGROUND SHALL <br />FOLLOW THE BELOW COLOR SCHEME: <br />a. NORMAL POWER - WHITE <br />b. UPS POWER - BLUE <br />c. LIFE SAFETY POWER -YELLOW <br />3. LABEL MATERIAL SHALL BE DURABLE, UV STABLE, RATED FOR OUTDOOR USE, AND ABRASION RESISTANT. WHERE ATTACHED TO <br />NEMA 4X EQUIPMENT, LABELS SHALL IN ADDITION BE CHEMICAL RESISTANT, <br />4. LABELS SHALL BE PERMANENTLY ATTACHED TO ENCLOSURE COVER WITH RIVETS UNLESS DOING SO COMPROMISES ITS NEMA / IP <br />RATING. LABELS FOR ENCLOSURES WITH WELDED SEAMS AND GASKETED DOORS SUCH AS THOSE RATED NEMA 12 OR NEMA 4 <br />SHALL BE INSTALLED USING PERMANENT WEATHER-, UV-, AND TEMPERATURE -RESISTANT DOUBLE -SIDED MOUNTING TAPE ONLY. <br />5. A SUBMITTAL WITH A COMPLETE LIST OF EQUIPMENT LABELS SHALL BE PROVIDED FOR ENGINEER APPROVAL PRIOR TO ORDERING. <br />6. LABELS SHALL INDICATE NO LESS THAN THE FOLLOWING: <br />a. EQUIPMENT NAME. <br />b. THE NOMINAL SYSTEM VOLTAGE WHICH SAID EQUIPMENT IS CONNECTED TO. <br />c. THE EQUIPMENT NAME SUPPLYING POWER TO SAID EQUIPMENT. <br />d. THE AVAILABLE FAULT CURRENT AT SAID EQUIPMENT. <br />PANEL LABEL DETAIL <br />FIRE ALARM HORN ONLY, <br />STROBE OR HORN/STROBE, <br />PAINT TO MATCH WALL <br />ALIGN WHEN MOUNTED <br />ON SAME WALL <br />FIRE ALARM PULL STATION 1 <br />1 <br />Q O <br />cv�oo 00 <br />" <br />ALIGN HORN ONLY DEVICE WITH TOP OF DOOR <br />FRAME, STOBE OR HORN/STROBE DEVICE 80" <br />AFF TO BOTTOM OF STROBE LENS <br />C <br />2" ABOVE BACKSPLASH <br />4" ABOVE COUNTERLno <br />�b o <br />W/O BACKSPLASH Fi <br />O <br />CABINET <br />(TYP.) <br />FINISHED FLOOR <br />NOTES: <br />1. MOUNTING HEIGHTS SHOWN ARE FROM FINISHED FLOOR (A.F.F.), UNLESS OTHERWISE NOTED. <br />2. LOCATIONS OF OUTLETS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL TAKE PRECEDENCE OVER <br />THESE MOUNTING HEIGHTS. FIELD LOCATE OUTLETS WITH ARCHITECT DURING ROUGH -IN. <br />3. INSTALL OUTLETS THAT ARE IN CLOSE PROXIMITY ON THE SAME CENTERLINE. OUTLETS THAT ARE <br />WITHIN 2'-0" HORIZONTALLY AND WITHIN T-0" VERTICALLY SHALL BE INSTALLED ON THE SAME <br />HORIZONTAL CENTERLINE LOCATED HALF WAY BETWEEN THE HEIGHTS SHOWN. OUTLETS THAT ARE <br />MORE THAN 1'-0" APART VERTICALLY SHALL BE INSTALLED ON THE SAME VERTICAL CENTERLINE, <br />4. VERIFY MOUNTING HEIGHT WITH LOCAL AUTHORITY. <br />5. ADA REQUIREMENTS SHALL SUPERCEDE STANDARD MOUNTING HEIGHTS WHEN THERE IS A <br />CONFLICT. <br />STANDARD MOUNTING HEIGHTS DETAIL <br />al <br />NOTES: <br />PROVIDE ARC FLASH HAZARD LABELING AND FIELD MARK ALL ELECTRICAL EQUIPMENT AS PART OF <br />ARC FLASH RISK ASSESSMENT PER 2015 EDITION OF NFPA 70E 130.5(D). THE LABEL MUST CONTAIN <br />THE FOLLOWING INFORMATION: <br />1. KNOWN SYSTEM VOLTAGE. <br />2. ARC FLASH BOUNDARY. <br />3. AT LEAST ONE OF THE FOLLOWING: <br />a. AVAILABLE INCIDENT ENERGY AND THE CORRESPONDING DISTANCE, OR THE ARC <br />FLASH PPE CATEGORY IN TABLE 130.7(C)(15)(A)(b) OR 130.7(C)(15)(B) FOR THE <br />EQUIPMENT, BUT NOT BOTH. <br />b. MINIMUM ARC RATING OF CLOTHING. <br />c. SITE -SPECIFIC LEVEL OF PPE. <br />ARC FLASH WARNING LABEL RE( <br />UIREMENTS DETAIL <br />NOTES: <br />1. ALL CONDUCTOR CONNECTIONS ARE TO BE EXOTHERMIC Gq <br />WELD TYPE. <br />2. UL LISTED WATER PIPE CLAMP SIZED ACCORDINGLY. <br />4� 3. UL LISTED REBAR CLAMP SIZED ACCORDINGLY. <br />€ 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE A NEW <br />GROUND ROD AS INDICATED. <br />NOT ALL GROUNDING ELECTRODES SHOWN MAY BE <br />PRESENT AT SITE. PER N.E.C. ARTICLE 250.50, THE <br />ELECTRICAL CONTRACTOR SHALL BOND TOGETHER ALL <br />PRESENT GROUNDING ELECTRODES. I LETTER (FILL) COLOR SHALL <br />BE BLACK <br />0 <br />LETTERING SHALL BEY" INDICATED VOLTAGE, F <br />HIGH NO. OF PHASES, <br />NO OF WIRES <br />U <br />Ck <br />NHA W <br />INDICATES WHERE THIS EQUIPMENT Q <br />120/208V, 3PH, 4W IS FED FROM (TRANSFER SWITCHES <br />MAIN BONDING JUMPER WILL HAVE TWO LINES) <br />(SIZE PER NEC 250.102) <br />METAL FRAME OF THE FED FROM MSB BKR.11 <br />BUILDING OR STRUCTURE PHASE A - BLACK WIRE <br />(NEC 250.52 (A) (2)) G N T PHASE B - RED WIRE ATTACH NAMEPLATE WITH (2) <br />SERVICE ENTRANCE EQUIPMENT SCREWS (MIN.) <br />PHASE C -BLUE WIRE <br />NEUTRAL - WHITE WIRE W <br />GROUND - GREEN WIRE Q <br />BONDING JUMPER GROUNDING ELECTRODE CONDUCTOR NAMEPLATE COLOR Q <br />{ BONDING JUMPER { LIFE SAFETY = YELLOW <br />(SIZE PER NEC 250.66) (SIZE PER NEC 250.66) (SIZE PER NEC 250.66) EMERGENCY =OANGE <br />NORMAL =WHITE <br />12,345 AFC / DATE <br />{ z. SEE NOTE 2 (TYP.) Z <br />BONDING JUMPER (SIZE PER NEC 250.66) <br />NON-METALLIC PROTECTIVE SLEEVE L INCLUDE MAXIMUM AVAILABLE FAULT CURRENT PER NEC 110.24(A) O�: LJ J '—' M r-A 0 Z U) <br />This item has <br />been digitally � <br />SEE NOTE 3 (TYP.) Signed and ,It <br />CONCRETE ENCASED REBAR Sealed by Cory A. <br />00 <br />(NEC 250.52 (A) (3)) Glass, PE on the <br />METAL UNDERGROUND WATER PIPE date adjacent to <br />GROUND ROD C (NEC 250.52 (A) (1)) o °° pppppOAAAAApQ� oOoothe seal W <br />°`GNo Digital Susing Signature. a' <br />250.52 (A) (5)) <br />No 80467 ' Printed copies of <br />e�E -this document <br />are not <br />3 GROUNDING ELECTRODE SYSTEM DETAIL 4 ELECTRICAL EQUIPMENT NAMEPLATE DETAIL °°<..... e?0� considered <br />= NONE E0 1 SCALE = NONE E0 1 SCALE = NONE o�N�9signed and <br />sealed and the <br />_F a SHA ,ya <br />authentication <br />code must be <br />verified on any U <br />{ i electronic copies. <br />i <br />Uco <br />m <br />5 <br />W <br />,w�,w C N <br />WL <br />0 NW <br />0 W � <br />U c <br />t� a " N <br />N <br />Zo 3 0 <br />c) —a. <br />UM O ch M 0 <br />J <br />i..l) - o <br />,+ (1)A , <br />�/ c ,�a0 M <br />2 'V oD <br />J � a�ic�v� <br />W N5�I <br />KTK I JIW I CAG <br />BY: ENG: APPRV: <br />[ R <br />SHEET DESCRIPTION: DETAILS SHEET ALL DETAILS ON SHEET MAY NOT NECESSARILY APPLY TO PROJECT) 0 7/5/2023 <br />