I Wff i <br />ALL STAIR STRINGERS <br />AND TREADS TO BE <br />#2 SYP (MIN.) <br />THREADS, RISERS, AND <br />3/4" PLYWOOD NOT <br />SHOWN IN DETAIL FOR <br />CLARITY <br />ALL WOOD TO WOOD <br />CONNECTIONS TO BE <br />GLUED (PL 200) AND <br />NAILED (MIN. (2)16d). <br />anvir.w,v ivi.inci ry �iu� ,vu ,v�w <br />FLAT STRAP NAILED TO RISER AND <br />THEN WRAPPED AROUND STUD <br />PLAN VIEW <br />SCALE: = 1'-0" <br />NOTE: <br />THESE DETAILS ARE NOT PLAN <br />SPECIFIC. THEY ARE PROVIDED TO <br />YOU AS A STANDARD TO CONSTRUCT <br />STAIRS. REFER TO PLAN DETAILS <br />FOR RISE AND RUN INFORMATION. <br />2x4 SPF NOSING GLUED AND <br />NAILED MATCH NOSING ON <br />OTHER TREADS <br />3/4" RISER CUT TO FIT <br />2x4 SYP BLOCKING <br />MAINTAIN BETWEEN 1/4" <br />FOR STRAP (SIMPSON <br />AND 1/2" GAP TOP AND <br />MTS12 w/ (14) 10d x 1 <br />BOTTOM, GLUED AND <br />1/2" NAILS) <br />NAILED TO STRINGER <br />2x12 TREAD <br />GLUED AND <br />NAILED <br />/. <br />DR FT S P <br />2x4 PT NOTCHED INTO <br />STRINGER AND T7 <br />APCONED 2x8 SYP DRYWALL STOP MUST <br />INTO FLOOR WITH GLU NOT TOUCH STRINGERS <br />STRINGER CONTACT 2x4 BLOCK IN KNEEWALL FOR 2x12 NAILING <br />POINTS x4 GLUED AND NAILED TO STRINGER <br />E FOR DRYWALL SPACING <br />H SECTION VIEW <br />SCALE: ' = V-0" <br />STRINGER <br />CONTACT <br />SIMPSON A <br />LSC EACH <br />STRINGER <br />�vvi v <br />DOES NOT BEAR IN <br />WALL GLUED TO <br />2x8 <br />F S ECTI <br />STRINGER MUST MAKE <br />FULL CONTACT WITH LANDING <br />I PT NOTCHED INTO STRINGER - <br />D NAILED TO FLOOR WITH GLUE <br />STRINGER CONTACT POINTS <br />ON VIEW "A" <br />SCALE: 1" = V-0" <br />SIMPSON A35 OR \ <br />LSC EACH <br />STRINGER 2x4 PT NOTCHED INTO STRINGER <br />AND NAILED TO FLOOR WITH GLU <br />2x4 CUT ON BEVEL AT STRINGER CONTACT POINTS <br />DOES NOT BEAR IN <br />WALL <br />SECTION VIEW "D" <br />SCALE: 1" = 1'-0" <br />FILLER STRIPS ADDED 4" PLYWOOD <br />GLUED & SCREWED TO <br />PLYWOOD DECKING <br />2x SYP CUT TO FIT <br />BEARS IN WALL <br />2x12 SYP <br />BEARS IN WALL <br />BULLNOSE DETAIL <br />SCALE: 1" = 1'-0" <br />INGER <br />GLUED <br />1 NAILED <br />SECTION D-D <br />3/4 PLYWOOD <br />ON DECK <br />--2x8 SYP GLUED <br />AND NAILED TO <br />FRAMING <br />2x4 DRAFT <br />2x12 <br />STOP <br />TREAD <br />GLUED <br />AND <br />NAILEC <br />2x4 PT NOTCHED INTO <br />STRINGER AND TAPCONED <br />INTO FLOOR WITH GLUE -AT - <br />STRINGER CONTACT <br />POINTS <br />i <br />SCALE: 1" = V-0" <br />;4 2x4 SYP BLOCKING <br />FOR STRAP <br />(SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS) <br />Ro <br />ALIGN THIS STUD WITH <br />FACE OF 2ND RISER <br />2x4 SYP BLOCKING <br />FOR STRAP <br />(SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS) <br />SECTION VIEW "B" <br />SCALE: 1" = V-0" <br />-ALIGN THIS STUD WITH FACE OF 2nd RISER <br />2x4 SYP BLOCKING <br />FOR STRAP <br />(SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS) <br />SECTION VIEW "E" <br />SCALE: 1" = 1'-0" <br />DR FT S P <br />F-1-C \ I I I 1�1 ] <br />2x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />1 GLUED AND NAILED TO STRINGER <br />OR DRYWALL SPACING <br />H <br />E SECTION VIEW <br />SCALE:' = 1'-0" <br />3/4 PLY\A <br />ON DECk <br />--2x8 SYI <br />AND N/ <br />FRAMIt <br />2x4 DRAF' <br />STOP <br />2x4 BLOCK <br />C <br />-3/4" RISER CUT TO FIT <br />MAINTAIN BETWEEN" <br />AND 2' GAP TOP AND <br />BOTTOM, GLUED AND <br />NAILED TO STRINGER <br />2x4 BEHIND RISER <br />BLOCKING FOR <br />1x4 GLUED AND NAILED TO STRINGER <br />STRAP GLUED TO <br />2x4 DRAFT <br />RISER AND TREAD <br />STOP <br />2x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />BLOCKING FOR 2x12 <br />PT UNDER 2x12 <br />ATTACH ALL COMPONENTS <br />OF STAIR TO CONC. W/a' X <br />2 a' TAPCONS @ MAX. 32" O.C. <br />G.1 <br />TOP OF <br />STRINGER <br />- 1x4 GLUED AND NAILED TO STRINGER <br />2x4 DRAFT <br />STOP A" <br />-2x8 SYP DRYWALL STOP <br />MUST NOT TOUCH <br />STRINGERS <br />2x4 BLOCKING FOR 2x12 <br />2x4 PT UNDER 2x12 <br />G <br />SIMPSON A35 <br />OR LSC EACH <br />STRINGER <br />OPTION: 2X4 CUT ON <br />BEVEL GLUED AND <br />NAILED TO SUPPORT <br />W/ SIMPSON H3 <br />2x12 SYP SCAB 2x4 GLUED AND NAILED (EACH <br />STRINGER [STRINGER <br />TO BOTTOM EDGE OF 2x12 <br />/ t STRINGER <br />/ PROVIDE MOISTURE <br />PROTECTION <br />ATTACH ALL COMPONENTS <br />OF STAIR TO CONC. W/ J" X <br />2 J" TAPCONS @ MAX. 32" O.C. <br />—1x4 GLUED AND <br />NAILED TO STRINGER <br />SECTION VIEW "C" <br />SCALE: 1" = 1'-0" <br />FLOOR TRUSS OR CONN. TO BOTTOM <br />GIRDER, FIELD VERIFY OF NEWEL POST <br />PER CONTRACTOR <br />(2) LAYER 4" EDGE GOLD PROVIDE SOLID BLOCKING <br />OSB OR PLYWOOD BELOW ALL NEWEL POST <br />OR 1"X16" LVL FROM JOIST TO JOIST. USE <br />ATTACHED W/ 12d NAILS 2 X 12 BLOCKS, GLUED AND <br />@ 6" O.C. TOP, BOTTOM NAILED TO JOIST. <br />AND VERT. <br />NEWEL POST <br />SECTION VIEW "G" <br />SCALE: 1" = V-0" <br />BLOCKING <br />0 1 /AIM k oUINO I MUk o I IUIN Ur. I /AI LO <br />(IF 11X17 REDUCE SCALE .5) SCALE: AS NOTED <br />SCALE: 1" = 1'-0" <br />JOINT <br />-TO <br />)ISTS) <br />NAILED AND <br />)TOP PLATE <br />NTO RIM BAND, <br />JD NAILED TO <br />WALL BELOW <br />JOINT <br />TO <br />)ISTS) <br />PSON <br />10d x <br />u <br />NEWEL POST LET INTO <br />THE BLOCK <br />PROVIDE <br />BLOCKING <br />2X8 BLOCKING <br />FOR NEWEL POST <br />TO ANCHOR TO. <br />(GLUED AND NAILED) <br />FLOOR <br />TRUSSES <br />ECTION VIEW "H" <br />SCALE: 1" = V-0" <br />MAR 2 5 <br />1 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approvpd <br />ror compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />N <br />N <br />O <br />N <br />Lo <br />N <br />� <br />i <br />f <br />_ <br />Lo <br />O <br />00 <br />- 6J,PJ <br />W <br />z <br />Q <br />O Lo - E <br />0 <br />c o <br />W <br />L o <br />NaCq <br />co <br />g <br />O -6 o <br />t <br />N <br />0 _� <br />Uj a * C <br />N <br />V <br />I` o E '-; .m <br />a <br />LU <br />0LLI Uj WOH <br />LU ��� �q�Yzx Z <br />LL � <br />QU <br />Q I— <br /><S5<- U) �pZLL <br />(�ffn��ZU OZ0W000o <br />LU <br />0 <br />Z Caj <br />0 O <br />� Z <br />�UCL y0O _zLL <br /><O— 5 MWoMUoQ <br />22� <br />0� o -QZ�Q <br />U_ Q 0 �QLL <br />a <br />O <br />CD <br />N <br />OW <br />1- 1 <br />� �kDo <br />. o <br />Q Lo L1) <br />� U0 <br />N <br />Q W Q Ln <br />QU<00 <br />Z <br />I- <br />LU <br />W <br />_jC) <br />�O <br />1� <br />N <br />N <br />O <br />N <br />O <br />i <br />N <br />O <br />0 <br />M <br />C.0 <br />� <br />00 <br />­ <br />-� <br />0 <br />N <br />00 <br />N <br />N <br />04 CV <br />O <br />CN <br />O <br />N <br />o <br />CV <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />CA <br />N <br />CA <br />CDe- <br />O <br />O <br />e- <br />ap <br />O <br />CV <br />H <br />CM <br />O <br />0 <br />0 <br />' <br />L <br />CV L ♦ <br />m�00000 <br />> <br />N <br />M <br />'tt <br />U-) <br />Cfl <br />. <br />ti <br />CO(� <br />Z Z <br />O <br />oWCO <br />� <br />CD 4_0�__ <br />a <br />� W <br />:z <br />LO-0 <br />z <br />z <br />W I- <br />=m0Z <br />Z <br />V <br />Z � J <br />Z 0 <br />TI <br />Q. <br />Z Z <br />Oa�W <br />o <br />W <br />Ln Z <br />Z r,,, <br />m Q O <br />ry • <br />Z <br />U <br />J <br />a <br />OU <br />O <br />Z <br />S T <br />Q <br />Z <br />z <br />w <br />J <br />W <br />N <br />O <br />LAST PLOT DATE <br />Dec. 15, 22 <br />z <br />J <br />STAIR DETAILS <br />