Laserfiche WebLink
A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />LINE OF <br />STRUCTURE ABOVE <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION B' <br />1 /4" = 1'-0" <br />SECOND FLOOR ELECTRICAL PLAN (ELEVATION B' <br />1 /4" = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO 7HE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2"AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />MAR 2 5 2023 <br />'V <br />Virtual Review Assist, Inc.'` <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH 771 <br />co <br />SWITCH <br />4 1/2"— <br />DOORJAMB DUPLEX Co <br />OUTLET c%� <br />TRIM o <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ_ <br />S <br />SMOKE DETECTOR <br />1 '-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />6 STRUCTURED WIRE OUTLET <br />E SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />—0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />—L PUSH-BUTTON DOORBELL <br />�A CLG MNT LT FIXTURE <br />'B CLG MNT PREWIRE - FIXTURE BY OWNER <br />-4- SURFACE MNT FIXTURE <br />WALL MNT FIXTURE <br />NOTE: <br />ND OPALEX - ALTERNATE <br />TUB/SHOWERCANS MAY BE <br />USEDIF <br />C 50W PAR30 NFL 6" WHITE BAFFLE APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />�00 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />,F CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />O SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />= S-36 = SINGLE 36" FLUOR STRIP <br />= D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 = DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />&T24 :aii 24" VANITY LIGHTING <br />36 _� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />0 CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />I ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />A/C REGISTER <br />C THERMOSTAT <br />TP SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />t� <br />N <br />i'0 <br />W <br />L o U <br />!� co L' v <br />VI <br />O -0C) u a <br />2 v <br />to <br />Do 2o <br />s U�� <br />•^N^`` <br />U LV QN <br />7W <br />V <br />L 0 E c <br />^ 0 a <br />W <br />w W <br />o w LU <br />w�~¢ x�_j x�YzW Z <br />�O�JQO¢�QwU00�0 <br />12�Q V <br />Q <br />cy x J Z i 3 0 Z 2 0 <br />0v)x90ZoR00mZz <br />0 H Q Q <br />p O <br />0 O Z <br />��ajv�wwF��W<0WJ <br />H� Z LLJ <br />Q O W OLLJ <br />w <br />2 U O Q <br />p <br />Ox o oQz <br />Q� <br />¢ <br />,L¢ <br />O <br />a <br />O <br />O <br />N <br />LU <br />Go C:)�+��pO <br />`M O) <br />J LLL <br />z <br />L10 <br />< LLjZ <br />� d a .M-•i <br />I— <br />DD <br />W <br />W <br />J� <br />d' <br />N <br />N <br />O <br />N <br />i <br />O <br />1 <br />N <br />O <br />0 <br />Oo <br />M <br />co <br />c- <br />ToT-- <br />T.-� <br />N <br />NNN <br />O <br />N <br />O <br />N <br />O <br />N <br />C) <br />N <br />C) <br />N <br />0 <br />N <br />O <br />N <br />O <br />N <br />i <br />O <br />i <br />O <br />� <br />O <br />i <br />Ob <br />OCD <br />N <br />� <br />A <br />i <br />� <br />O <br />� <br />O <br />O <br />CD <br />O <br />CD <br />i <br />O <br />O <br />N <br />O <br />0 <br />0 <br />N0 <br />L ! <br />i <br />N <br />0 <br />M <br />0 <br />'q <br />0 <br />U-) <br />0 <br />(0 <br />0 <br />I�_ <br />Cr <br />000 <br />Z Z <br />4_0 <br />wU <br />oWo <br />5; <br />Q O <br />Q <br />Uo�o <br />Q <br />OW=Q <br />LC) -0 <br />Z. <br />Z <br />LU P <br />co O z <br />V <br />Z J <br />a <br />0 <br />� <br />nzIx <br />Z Z <br />OCL <br />>_ W <br />Z r-I. <br />Z <br />¢ p <br />Z <br />U <br />� <br />OV <br />MM0 <br />W <br />o: <br />Z <br />A6 <br />Z <br />z <br />w <br />J <br />LU <br />M <br />o <br />O <br />LAST PLOT DATE <br />Dec. 15, 22 <br />z 0 <br />1 ST & 2ND FLOOR <br />J <br />ELECTRICAL PLAN B <br />