Laserfiche WebLink
JL --- - - - J- _ w 1 1 f 1 <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8"CEMENT <br />PLASTER <br />12 MIL DRYLOK ` CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />4) SEALANT JOINT <br />'%.. <br />OUTSIDE EDGE OF <br />WINDOW BUCK <br />5) SEALANT FROM <br />WINDOW FRAME <br />ACROSS WINDOW BUCK <br />, <br />AND EXTEND TO <br />MASONRY <br />6) TOOLED SEALANT <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />1) SEALANT AT <br />WINDOW BUCK TO <br />MASONRY <br />2) SEALANT JOINT <br />INSIDE EDGE OF <br />WINDOW BUCK <br />WINDOW FRAME <br />ATTACHED <br />PER CODE <br />REQUIREMENTS <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SiLL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />314" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />-V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />WEATHER <br />RESISITIVE <br />BARRIER <br />"^ WEATHER <br />JE BARRIER & <br />IARILY SECURE <br />WOOD FRAME CONSTR, <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISmVE O <br />BARRIER SEAL TOPS OF JOISTS <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up 8 temporarily secure weather <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under �� <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head 2 <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NITS <br />FLANGED WINDOW WP0 1 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />S <br />DO NO' <br />BOTTO <br />Fl enir_i <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />ure�rluui <br />SCS 0602 WINDOW FIN INTERFACE WITH SELF -ADHERED FLASHING <br />EXTRUDED SHOULDER DECK JOIST <br />SELF -ADHERED FLASHING 2x FRAMEWALL <br />PRODUCTS DETAILS TILE FINISH <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail instructions <br />Refer to the number marked as # in each detail that corresponds to the <br />numbered items in the list of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of Installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />1/2" DUROCK- <br />8" CMU -- <br />4"OR8"CMU <br />(PER SEAT DEPTH) <br />FILL WiTH GROUT - <br />SLOPED MUD BED <br />VINYL SHOWER PAN <br />aSHING <br />O <br />8 <br />E <br />AM <br />02 <br />W P07 <br />1'-4" PER PLAN <br />FEATHER R€SiSTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />3/4"-l" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIEC <br />THRESHOLD OF DOOR AN <br />UP JAMB 6", USE LIQUID N <br />OR EQUAL WEATHER PRC <br />SECTION -A (SEE DETAIL WPI <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />Z <br />g <br />X <br />w <br />a - <br />(A <br />U) <br />w <br />U <br />w <br />cc <br />cc <br />w <br />0 <br />SHOWER SEAT I W P 11 <br />�-- DOOR ROUGH OPENING <br />WINDOW UNIT <br />SLOPE <br />FLASHING REQUIREMENTS <br />0.3 in: 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />3J4~-i"BEAD of ON; rll (0.6 cm - 30. cm) include flashing as described in Section R703.4. <br />ADHESIVE TO BE APPLIED UNI)I.R SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6" USF LIOUIL;D EXTERIOR R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water <br />NAIL BRAND OR EQUALWEA1 HLR EX FIN. within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of <br />PROOF CAULKING <br />SELF -ADHERED FLASHING BUILDING PAPER draining to the exterior water that penetrates the exterior cladding. <br />Y-> WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />suBFLGOR - -� approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No 15 asphalt felt shall be applied horizontally <br />with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />�_- approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No.15 asphalt <br />RIM JOIST felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building <br />appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703,7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based <br />-1' sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />2 oi individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in <br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />('� SELF -ADHERED FLASHING <br />W P V 2 CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER P Q,�1 Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT -. substantially nonwater-absorbing layer or designed drainage space. <br />NEEDED IN CORNERS ADHESIVE <br />;TALL JAN1 or F I:y ASPHALT ADHESIVE R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanical) attached flexible flashing shall be applied <br />.ASHrNG.I�.a+E t� ICI al:i THROUGH SELF -ADHERED g• PP 9� Y 9� Y 9 PP <br />ASHING, SEE FLASHING `SELF -ADHERED FLASHING shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />.ANGED WiNDc w g g PP <br />EE DETAIL VJ'P01) used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the <br />SCORED - entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />LF-AbHERED I- LASHING, [ Y`` �� (BEFORE FOLOlNG. SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />(TEND A MINIMUM t+" RELEASE PAPER TO EXPOSE <br />ASi�iESv JE AS 3NCYVN, contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />ERTiCALLY F ROM <br />)TTOM OF ,y flashing in exterior walls shall comply with AAMA 714, The flashing shall extend to the surface of the exterior wall finish. Approved fleshings <br />1PESHOLD shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />2> shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following- <br />(5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details are <br />4 <br />not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />(u6) sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />SELF -ADHERED FLASHING 1.3 1.3. In accordance with other approved methods. <br />/� / <br />Y Y P05 INSIDE CORNER W P06 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMAfWDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground 3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />�7 ,5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />1- i 6.6.At wall and roof intersections. <br />A-' _ ___ ___..�� water Resistant Barrier 7. 7.At built -In Mutters. <br />:LF-ADHE, <br />,TCH <br />flERED FLASHING <br />(' 1 <br />2. <br />4. <br />i 5 `r <br />WP08 <br />PIASTER STOP .- <br />CONTINUOUS BACKER - <br />ROD & S I AL ANT <br />FOUNDATION WEEP SCREED <br />-STRIP OF SAF <br />j DRAINAGE PLANE WRB <br />J - BOND BREAK WRB <br />SF LATH <br />�X <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />• <br />- 3-1/2" INCH FLANGE <br />II j <br />"U THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />1 <br />DRIP SCREED PLASTIC; <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />Lath <br />Sheathing <br />Stucco <br />WP09 <br />LEGEND <br />SELF ADHERED FLASHING (SAF) o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) V <br />BOND BREAK WEATHER RESISTANT BARRIER - -- - <br />SELF FURRING (SF) LATHPLASTER ACCESSORY <br />ACCESSORY <br />SHEATHING, 'OSB'. PLYWOOD. DENSGLASS <br />1STER STOP A j <br />NTINUOLIC BACKER ROD J <br />EALANT <br />MENTITIOUS FINISH <br />CTURAL FRAMING <br />CTUUPAL SHAAT HiND <br />OF SAF <br />JAGE PLANE WRB <br />BREAK WRB <br />TH <br />WP10 <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />4­0 <br />> <br />O <br />rCL <br />L <br />Q <br />Cv <br />�- <br />0 <br />.� <br />U <br />0 <br />.N <br />=3 <br />-0 <br />C6 <br />cu <br />W <br />O <br />p <br />- <br />N <br />c <br />�-oU <br />Co <br />p <br />> <br />m <br />C:L <br />.c:: <br />u� <br />Q <br />MAR 2 5 <br />Virtual R <br />Plans Review c <br />for compliance <br />few Assist, inc. <br />Pleted and <br />wit <br />by Debra A <br />approved <br />the 2020 FBC 7th Edit <br />e Klahr PX230o <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC 1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1 /2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />cn <br />0) <br />ICU <br />> <br />O <br />-e-•+ <br />O <br />L <br />_0 <br />Q <br />ICU <br />CCU <br />m <br />w <br />Z <br />Z <br />d <br />Q_ <br />SHEET NO. <br />WP1 <br />■ <br />