Laserfiche WebLink
7 5/8' <br />2x8 <br />HEADER <br />SEE Q/S, <br />(4 12" <br />D SH- <br />wC? <br />CO <br />w <br />P: <br />TIE BE/ <br />30'-0" <br />OVERALL <br />8'-5 5/8" 00 12'-6 3/8" 9'-0" <br />42"X42" AC PAD, <br />SEE SHEET SN1 <br />FOR AC UNIT <br />3 1/2" HOLD DOWN- <br />2' 0" <br />SH 25 <br />HB HD AT 6'-8" ° i 00 <br />EGRESS <br />5068 SGD <br />BEDROOM #2 <br />10'-0" X 12'-4" GREAT ROOM <br />8'-8" CLG <br />12-7 X 15-11 <br />00 <br />8'-8" CLG <br />o - <br />00 <br />b � <br />i <br />CV <br />10" r <br />5'-0" 6'-10 1/2" 16-0 1 /4" <br />6" WALL <br />�3) STUD <br />(2) 2068 BF OLUMN <br />BELOW <br />2" d'T-7" 9'-2 1/4" 11 12'-10 5/8" <br />2X4 KNEE <br />WALL, TOP <br />AT 34 1/2" <br />�w KITCHEN II II <br />12'-7" X 7'-0" <br />°O 8'-8" CLGUj <br />� <br />BATH M U) O _ DINING ROOM <br />8'-8" CLG (0 Y a o II N 15 -11 X 17 -9 <br />(0 z GO O II II 8 -8 CLG <br />TP <br />O <br />II II <br />CD <br />RANGE <br />ii <br />00 <br />PTS <br />�O <br />W/ HOOD <br />II II <br />III II <br />III <br />II <br />M <br />II IL—� <br />—ILL <br />iv <br />V 3" <br />7� <br />_ <br />N <br />2'-3 1/2" <br />WALL <br />" o <br />r <br />5'-3 3/4" <br />`L <br />8'-8 1/2" <br />2'-3 7/8" 10 1 <br />6-3 1/2" <br />PANTRY <br />iv <br />PLUMBING <br />u, <br />REF <br />STACK <br />6'-7" <br />, <br />WALL <br />B.U.C. <br />r <br />(4) 16" <br />f <br />IT <br />n <br />41�PROTECTIVE <br />BOLLARD <br />TWO CAR GARAGE <br />18'-9" X 20'-0" <br />N <br />4" INSULATE <br />BRG WALL <br />(3) STUD <br />COLUMN BELOW <br />20 MIN FIRE <br />RATED DOOR W/ <br />WEATHER STRIP- <br />(2) 2x8 <br />HEADER SEE <br />Q/S4 <br />4" INSULATED <br />BRG WALL <br />� OPEN POSTION <br />— — — — — — — — — —I <br />� I <br />� I <br />I I <br />TIE BEAM TIE BEAM <br />AT 8'-8" AT 8'-E" <br />16070 <br />- — — — — — — — — — — — — — — — J <br />LINE OF STRUCTURE 16" X 16" X 20" <br />ABOVE A.F.F. CMU BASE W/ <br />(4) #5 VERT. TYP OF (2) <br />v <br />M <br />N <br />a0 <br />FOYER <br />8'-8" CLG <br />w <br />r` <br />r <br />00 <br />O <br />M <br />G <br />Oo <br />A <br />0o ih <br />L <br />'0UI <br />ti <br />7 5/8" <br />T-4 1/2" <br />2668 <br />N <br />L 7�. <br />3 1 /2" SH 1/2 34' 11 <br />(0 DAT64" i <br />M T MP.GLA�S <br />ENTRY III <br />16-0" -4 1 5'-8" 2'-4 1'4' <br />18'-8" 1 '-4" 10'-0" <br />30'-0" <br />(2) 2X8 TOP <br />8'-8" W/ (2) MSTA24 <br />TO POST EACH END—) <br />FIRST FLOOR PLAN - ELEVATION A <br />1/4 If = 1 '-0" <br />7 5/8" <br />00 <br />N � <br />�Q <br />0 <br />�0 <br />N <br />J <br />J - <br />< a <br />L0 > <br />O <br />0 <br />N <br />N <br />00 W <br />m� <br />W <br />�Q <br />TIE BEAM <br />AT 8'-8" <br />\�__(2) 2X8 TOP <br />8'-8" W/ (2) MSTA24 <br />TO POST <br />—6X6 PRESSURE <br />TREATED WOOD POST <br />W/ PAU66 TO CONC <br />30'-0" <br />2'-10" 24'-4" 2'-10" <br />(2)2X6 HEADER <br />SEE M/S6 - TYP. <br />SH 25 2ND FLOOR SH 25 <br />D AT 7'-3" WINDOWS _ HD AT 7'-3" <br />EGRESS d EGRESS <br />Ln <br />I <br />I <br />4„ <br />13'-0" <br />'-3 3/4" <br />'-3 3/4" <br />1 V-8 1/2" 4" <br />19 <br />mV <br />rn <br />u-00 <br />c 1 m <br />CD <br />co <br />BEDROOM #3 <br />BEDROOM #4 <br />- <br />10-3 X 11 -8 <br />12'-9" X 11'-11" <br />�' <br />8'-0" CLG <br />0 <br />8'-0" CLG <br />r <br />r <br />� <br />r- <br />r <br />CV <br />DO <br />r <br />11 1/2" <br />13'-0" <br />3'-8" <br />5'-7 1/2" 6'-1 " <br />2668 N <br />2668 <br />o <br />(0 <br />L-P <br />r <br />1 <br />cv <br />�6, <br />c�6 TP <br />_ <br />e� <br />��' <br />00 <br />_ <br />#2 <br />CLG`"W.I.C. <br />" WALL <br />;BATH <br />I <br />T10. <br />N to <br />N <br />r <br />— <br />BEDROOM #5 R & S <br />Q r <br />\ W D <br />r <br />11'-7" X 9'-10" <br />"' <br />HANSEN VENT <br />`"? U) <br />8'-0" CLG 12" DP 4 S � <br />() <br />r' <br />BOX <br />C\I W <br />p LU <br />_ <br />r'56 <br />r22"x36" <br />0� <br />= <br />6cP _ <br />N <br />Cl) <br />AATTIC <br />ti� LAUNDRY <br />ACCESS <br />0 <br />2 <br />66d' <br />M <br />v <br />v <br />LOFT <br />N" <br />r <br />�g <br />10'-1" X 15'-5" <br />8'-0" CLG <br />o <br />00 <br />2 Q <br />r <br />10'-3 1/2" 3'-8" L <br />IT-4" 4'-8 1/2" <br />L 7'-4" <br />36" LOW 1 <br />r <br />BEDROOM #F <br />WALL A3 <br />c' <br />11'-4" X 1 V-0" <br />o <br />r DRAIN <br />`' <br />8'-0" CLG <br />u- <br />_ <br />)N <br />N W <br />N <br />SHOWER <br />=< <br />Q O <br />. <br />o <br />U) <br />1 <br />r <br />1 <br />HEAD & ---- <br />VALVE 1 <br />rr <br />o W <br />q N <br />06 <br />(° <br />16 <br />- <br />3 <br />N <br />---- <br />1Ise <br />A3 <br />N <br />14 <br />ZVOOV <br />ti�6� <br />M 13 <br />4,. <br />1 V-8" <br />1'-8" <br />4'-2 1/2" Lk 1 3'-11" 1 <br />N <br />lot <br />of z <br />r <br />2'-1 3/8" a 10 --- <br />--- <br />9 <br />71 <br />8 <br />8" EXT <br />6" WALL 7 7 <br />FRAME <br />WALL <br />o <br />N� <br />0. BATHQCC <br />�w 6 <br />8'-0 CLG O; 5 <br />OWNERS SUITE <br />---- <br />C <br />- <br />17'-0" X 13'-0" <br />4 <br />T <br />r <br />Oil <br />r <br />8'-0CLG <br />i <br />W.I.C. 3 --- <br />` <br />- <br />36" H. <br />`" `Oobd, <br />r <br />Q <br />CONT Qc <br />n RAILING <br />O <br />I i <br />TP M <br />(2)2X6 HEADER <br />_ <br />( C/) U <br />SEE M/S6 -TYP. <br />2ND FLOO <br />SH 1/2 34 8" EXT <br />WINDOWSR <br />HD AT 7-3 FRAME <br />WALL <br />BUC W/ (2) <br />2-PLY BUC W/ (2) <br />002-PLY <br />�'' <br />00 <br />MSTA36 <br />STRAPS <br />MSTA36 STRAPS <br />�n <br />TO <br />FLOOR <br />TO FLOOR <br />TRUSS <br />BELOW <br />TRUSS BELOW <br />SH 1/2 34 <br />AT 18'-0" <br />SH 25 SH 25 <br />HD AT 7'-3" HD AT 7'-3" <br />EGRESS <br />6'-10" 6'-10" <br />13'-8" <br />CANTILEVER <br />r7 u H 1 ! -.S <br />T-2" T-2" 2'-8" 7'_4" <br />64" 10'-0" <br />30'-0" <br />SECOND FLOOR PLAN - ELEVATION A <br />1 /4" = 1 '-0" <br />GENERAL NOTES: <br />ALL WINDOWS TO HAVE FLUSH SILLS. PITCH TOP SILL <br />FIN AWAY FROM WINDOW FRAME. <br />VERIFY ALL WINDOW AND DOOR ROUGH OPENING SIZES <br />WITH THE MANUFACTURER'S SPECIFICATIONS. <br />INSTALL RND DRYWALL BEADS AT HORIZ & VERT <br />CORNERS, EXCEPT AT EXT WALL OPENINGS OR AS <br />NOTED. <br />USE SQUARE CORNER BEAD AT DRYWALL NICHES & <br />REC CLG DETAILS; REC CLG SURFACES SHALL HAVE <br />SMOOTH FINISH. <br />LOCATE ALL PLUMBING & EXHAUST STACKS BEYOND <br />THE FRONT ELEV ROOF RIDGES, IF ALLOWABLE PER <br />CODE. <br />THE GARAGE IS TO BE SEPARATED FROM ADJACENT <br />LIVING AREA AND ATTIC SPACE BY 1/2" GYPSUM BOARD <br />AND HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8" <br />THK. TYPE "X" GYPSUM BOARD (OR EQUIVALENT) <br />APPLIED TO THE GARAGE SIDE. <br />TOWEL BAR - (T.B.)* = 42" A.F.F. OR U.N.O. <br />TOWEL BAR ABV TUB DECK* = 36" ABV. TUB DECK <br />TOILET PAPER DISP. - (T.P.)* = 20" A.F.F. <br />ROD AND SHELF (SGL)- (R/S) = 60" A.F.F. <br />ROD AND SHELF (DBL)- (R/S) = 40" & 80" A.F.F. <br />CORNER SHELF = 56" A.F.F. <br />MEDICINE CABINET - (M.C.) = 75" TO TOP OF CABINET A.F.F. <br />*PROVIDE 2X BLOCKING IN WALL AT ALL LOCATIONS FOR <br />T.B. AND T.P. <br />WALL LEGEND: <br />ALL EXTERIOR WALLS TO BE CONSIDERED SHEAR <br />RESISTANT COMPONENTS. <br />8" CMU W/ 1X3 PT FURRING STRIP <br />3/4" INSUL BOARD 1/2" GYP <br />8" CMU <br />NON -BEARING 2X4 STUD W/ 1/2" GYP. <br />UNO <br />BEARING WALL 2X4 16" O.C. W/ 1/2" <br />GYP. LINO <br />p = FILLED CELL W/(1) #5 VERTICAL <br />® = FILLED CELL W/(1) #5 TURNED 2'-0" INTO SLAB <br />= FILLED CELL W/(2) #5 VERTICAL <br />C = FILL CELL TO ONE COURSE ABV PIPE (NO REBAR) <br />STAIR DATA <br />STAIR <br />MARK <br />RISERS <br />TREADS <br />LANDINGS <br />TOTAL RISE <br />A <br />17 AT 7 3/32" <br />15 AT 10" <br />1 <br />10'-0 3/4" <br />TREADS WITH 1" NOSING <br />SQUARE FOOTAGE: <br />AREA <br />PROPOSED <br />FIRST FLOOR LIVING <br />1110 <br />SECOND FLOOR LIVING <br />1470 <br />TOTAL LIVING SQ FT 2580 <br />ENTRY <br />60 <br />GARAGE <br />403 <br />TOTAL SQ FT 3043 <br />INSULATION REQ: <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2X4 <br />R-11 / R-13 KRAFT FACED <br />EXT FRAME 2X6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11 / R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />MAR 2 5 2023 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approve <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />ALLOWABLE WIND SPEED DESIGN PRESSURE <br />(140 mph, enclosed, 3 sec. gust, 2.1/12 to 6.9.12 pitch, <br />Exposure C, Height=30 ft, Importance Factor=1.0, End <br />Zone= 4 ft) <br />As per Florida Building Code 7th edition (2020), <br />Residential Table R301.2 (4) (Wind Speed Conversions) <br />and ASCE 7-10 Methods <br />WALL <br />TRIBUTARY <br />AREA (ft)2 <br />INTERIOR <br />END <br />10 <br />39.4 <br />-42.1 <br />39.4 <br />-51.8 <br />20 <br />37.6 <br />-40.5 <br />37.6 <br />-48.6 <br />50 <br />35.2 <br />-37.3 <br />35.2 <br />-43.7 <br />100 <br />33.4 <br />-35.6 <br />33.4 <br />-40.5 <br />GARAGE DR <br />30.0 <br />-33.9 <br />30.0 <br />.33.9 <br />\ N <br />N <br />0 <br />- �v <br />co <br />F•, <br />jg <br />a < <br />Z <br />" W <br />p <br />�. <br />«k <br />W <br />0 <br />z <br />a <br />0 0 <br />_W L 0 <br />cod <br />N <br />v) <br />� M <br />U d (C)") <br />o <br />rn �� 0 IL o Q <br />22 <br />t U 6 <br />LLJ <br />1` o <br />7C) <br />v �a <br />V, <br />LU W <br />0 LLI LU U) w 0 I— <br />uj <br />Lu F-Q O� �J 0�~Z� zW �- O <br />V<� <br />ooJo <br />0JLw°z2°~L <br />C1W�W�OwO�mo=zzOZ <br />zO��pF_<uL <br />i<WY <br />OIL <br />LL <br />0 <br />00 oQof <br />,La I—aw <br />i� <br />O <br />Z C4 <br />0W <br />>_ (n 0 <br />M r- <br />J LO <br />� U) LL_ <br />()� IZ <br />_e) <br />>- O <br />Q Q <br />Z C) �— <br />3: <br />LUz <br />W <br />,J O <br />O <br />I <br />I <br />I <br />O <br />o <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />QD <br />ti <br />r <br />M <br />M <br />r <br />C) <br />00 <br />C) <br />C <br />CDO <br />O <br />cc,:) <br />cc,) <br />z <br />O <br />W <br />0 <br />N <br />LO <br />> <br />o <br />r <br />0 <br />N <br />CI) <br />0 <br />� <br />o <br />� <br />I <br />I <br />M� <br />}~ <br />zz <br />W <br />¢w <br />O+�-+ <br />W <br />00Oo <br />O <br />V <br />L)jUcn <br />Lo^ <br />i� <br />G <br />Z)zj_ <br />Oro <br />Z <br />a <br />�a <br />W 3: Q <br />m r-W <br />F-2 <br />^' <br />l V <br />O <br />�O� <br />W <br />F-0 <br />0zo�o <br />O <br />Z <br />1 <br />V <br />aZLL <br />W <br />mz <br />Q <br />F- <br />U <br />� <br />O <br />z <br />z <br />z <br />WV1_ <br />o <br />0 <br />LAST PLOT DATE <br />• . <br />December 14, 2022 <br />z <br />1ST & 2ND FLOOR <br />PLAN A <br />