My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6283 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6283 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 3:14:41 PM
Creation date
2/28/2025 11:09:19 AM
Metadata
Fields
Template:
Building Plans
Street #
6283
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
5967
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6'-5" <br />61 <br />BEDROOM <br />#4 <br />I <br />BEDROOM <br />#5 <br />5'-10" <br />1 <br />V <br />BEDROOM <br />#6 <br />6'-7" <br />OWNERS <br />BEDROOM <br />19 <br />F_ <br />SS <br />EO <br />5'-11 " <br />h <br />EDRO M <br />0 #3 <br />Iti <br />cs <br />L— �J <br />\ LIGHT AND <br />SWITCH IN <br />TTIC <br />008 <br />T-9" <br />GFI LAUNDRY <br />77 <br />LOFT <br />F <br />V-7„ <br />/ cSii <br />-- — <br />_.�' <br />OWNERS <br />BATHROOM <br />TO 1ST <br />FLR ELEC <br />SECOND FLOOR ELECTRICAL PLAN (ELEVATIONS A & B' <br />1 /4" = 1'-0„ <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />MAR 2 5 2023 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH --,— <br />SWITCH—° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET ih <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />S <br />SMOKE DETECTOR <br />V-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�F TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-69- SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />--� PUSH-BUTTON DOORBELL <br />H L CLG MNT LT FIXTURE <br />{} CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />{- WALL MNT FIXTURE <br />NOTE: <br />C 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />41 50W PAR30 NFL 6'" WHITE BAFFLE <br />C USED IFAPPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />0 50W PAR20 NFL 4" MINI ROUND RECESS <br />�� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />ss COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:R 24" VANITY LIGHTING <br />F;;;: 36 :;;R 36" VANITY LIGHTING <br />�48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />IMEEF MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />E3 A/C REGISTER <br />OT THERMOSTAT <br />SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />to <br />N LO <br />U <br />co N ai <br />nowNam( <br />U W 2u P <br />A' o <br />2 Oo 2 o <br />O � o R Q <br />•nNl <br />W QC�r <br />00 E " <br />W <br />}i <br />V a a <br />LU W <br />LLI Uj W O �- <br />�-Q 0 xj,z� z <br />OU <br />F <br />Z <br />�O¢3CJr�Oz200Q_�xz <br />aU)0z0R00 nZW v <br />� nWWWd'Q� J <br /><WzOILOQ0<Mz2 <br />Qgf-�_ 2W2) <br />U_ <br />OW <br />OW D. OQa� <br />Q O <br />W tL <br />o <br />Z N <br />OW <br />F— <br />Q M O <br />Q M IL r-) <br />�wLLz <br />< W U? <br />F- W a M_ <br />Q 00 <br />Q <br />Z U F- <br />W <br />W <br />J O <br />O <br />t� <br />I <br />I <br />I <br />O <br />o <br />0 <br />0 <br />0 <br />N <br />fZ <br />N <br />0 <br />N <br />M <br />N <br />M <br />N <br />r <br />0 <br />rn <br />o <br />a <br />N <br />I <br />I <br />O <br />z <br />0 <br />0 <br />o <br />o <br />I <br />I <br />O <br />w <br />O <br />N <br />L? <br />Lo <br />qq <br />O <br />O <br />O <br />O <br />z ~ <br />vV <br />Qz <br />O <br />zW <br />0) <br />-F--+ <br />O <br />W <br />U <br />0 O O_ <br />LLJ () V U5 <br />O <br />:Dzj <br />OF-C <br />Z <br />a <br />Q�--I <br />W - Q <br />F-�w <br />N <br />0 <br />SOW <br />■ ■� <br />W <br /><t::) <br />Q <br />Ozof° <br />OU <br />wLL <br />z <br />az <br />�z <br />Q <br />F� <br />� <br />OU <br />MMO <br />W <br />z <br />A6.2 <br />� <br />z <br />z <br />z <br />W <br />UjV_J <br />0 <br />o <br />LAST PLOT DATE <br />• <br />December 14, 2022 <br />z <br />O <br />2ND FLOOR <br />ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.