My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6732 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6732 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 6:56:41 PM
Creation date
2/28/2025 11:09:33 AM
Metadata
Fields
Template:
Building Plans
Street #
6732
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6518
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONY. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />MAX &EACH END ALTERNATE BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />^ CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. , <br />---- /--WOOD TRUSS —� <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE EXTEND <br />FOUNDATION PLAN SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />4" <br />#3 STIRRUPS AT 4'-0" <br />DEPTH H N <br />� W E <br />i, <br />A <br />EXCEEDS 30" <br />GRADE <br />1'4' <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />2X4 CONT. AT <br />T & B CHORD <br />WOOD <br />TRUSS <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />CONC. MASONRY <br />STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />2„ <br />-�� -=*=�\ <br />• w <br />4'' <br />z <br />� <br />PORCH SLAB SEE - <br />J N <br />° a <br />FOUNDATION PLAN <br />- <br />w <br />�... <br />z <br />(2) #5's CONT. T&B <br />', <br />t . <br />NY <br />W/ #3 STIRRUPS AT <br />Ct z <br />4'-0" WHEN DEPTH <br />_ <br />T <br />EXCEEDS 30" <br />LOWER OR <br />GARAGE SLAB <br />SEE PLAN <br />LARGE <br />STEP <br />DOWN <br />_1 7 <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />2X4 STUDS w/ SIMPSON <br />SP1 w/ (10) 10d NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />SEE ROOF <br />PLAN I SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�'A TRUSS <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />JACK <br />MAX 24" SPAN (EITHER USSES HIP <br />SIDE OR BOTH IF REQ'D) G.T <br />(2) 12D NAILS — <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />WOOD POST. SEE FLR__T <br />PLAN FOR SIZE & BASE <br />CONNECTION SEE <br />PLAN <br />EXTEND <br />--_—* SLAB 11/2" <br />I J4 <br />(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />PORCH SLAB SEE <br />- WHEN DEPTH <br />— 7 <br />FOUNDATION PLAN - -- EXCEEDS 30" <br />-- GRADE <br />1 -4 <br />ENTRY PORCH SILL 14 <br />SCALE: N.T.S. <br />FOR COLUMN INFO <br />WOOD OR MASONRY I <br />INTEGRATE MASONRY <br />ABOVE MASONRY <br />KNEEWALL INTO CMU BASE OR <br />PIER SEE FLOOR Al <br />MAIN HOUSE PER ELEVATION IF <br />PLAN FOR COLUMN <br />REQUIRED <br />INFO <br />MASONRY KNEE WALL MAX 3 <br />= <br />COURSES W/ TOP K.O. COURSE <br />CMU BASE W/ (1) #5 I I <br />W/ (1) #5 CONT. FILLED CELL <br />VERTICAL EACH <br />REQ'D @ MID SPAN MAX 6'-8" <br />CORNER FILLED <br />MAX 3 <br />SOLID. SEE ELEV. <br />I II <br />I I <br />I <br />I <br />I <br />I <br />IP <br />I <br />I <br />SECTION FOR #3 STIRRUPS AT 4'-0" <br />SEE CUT <br />CONTRACTOR TO INSTALL • ° <br />MIN 3" x 3" WEEP HOLE MORE INFO WHEN DEPTH <br />ALONG w/ PITCHING SLAB EXCEEDS 30" <br />V-4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />SIMPSON LSTA18 <br />W/ (12) 10d NAILS <br />CENTERED AT <br />SPLIT TO TIE <br />BEAMS TOGETHER <br />ENTRY PORCH SILL r16 <br />SCALE: N.T.S. <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />#5 REBAR CONT <br />@ SLAB LEVEL <br />EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />------ SEE PLAN <br />SIMPSON HUC410 w/ (14) 7 FOR CANT. <br />16d INTO HEADER & (6) <br />10d INTO BEAM -SEE <br />ROOF PLAN FOR MORE I <br />INFO <br />SEE FLOOR PLAN FOR I i I <br />COLUMN SIZE & BASE I 7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN --I CONNECTION INFO REQ'D ONLY WHEN <br />FOR COLUMN SIZE INDICATED ON BM. <br />& ADDITIONAL INFO. — — — — — — — — — — — — — — S(HFF)uI F/PI AN <br />EXTERIOR SHEATHING <br />ATTACHED PER <br />NAILING SCHEDULE <br />2X4 BASE PLATE W/ <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />SIMPSON MTS12 w/ <br />—xx <br />(14) 10d x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />16" FLOOR SYSTEM <br />FLOOR GIRDER <br />SEE PLAN FOR <br />SEE PLAN FOR <br />DIRECTION <br />CONNECTION <br />SECTION @ <br />FLOOR <br />CONNECTION 22 <br />SCALE: N.T.S. <br />LY <br />OPTION A SCHQEDUNE/PLAN N OPTION g COLUMN SIZE & BASE OPTION C <br />INDICATED ON BM. CONNECTION INFO <br />COMMON BM. TO POST ATTACHMENT rAN)l, <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO.. <br />SIMPSON (2) HTS20 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />A F A <br />SEE PLAN FOR <br />_J <br />SEE PLAN FOR <br />CANT. IF <br />INDICATED <br />CORNER - SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />XX <br />COMMON BM. ATTACHMENT <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />BM. SPLICE OVER <br />CL / CENTER OF POST <br />MIDDLE <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />—TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL 7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d • <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d <br />NAILS TO LEDGER AND J/S6 FOR MORE INFO. <br />2X8 #2 SYP CONT. LEDGER W/ VERIFY WITH PLAN FOR <br />LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS <br />INTO END OF EACH FLOOR (IF PARALLE SEE 2/D2 FOR <br />TRUSS, 24" O.C. MAX. (AT EACH BLOCKING INFO) <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF rg <br />SCALE: 1/2" = 1'-0" <br />Y2' CDX PLYWOOD OR %6" O.S.B. <br />SHEATHING REQ'D FROM BOTTOM <br />OF WALL TO ROOF SHEATHING <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES — <br />SEE PLAN MAX. <br />24" STEPS <br />SEE PLAN FOR OPT. <br />STAIR INFO. IF <br />CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />GARAGE OR <br />LOWER SLAB <br />SEE PLAN <br />SECTION <br />SCALE: N.T.S. <br />COMMON TRUSS <br />W/ INTERIOR BRG. <br />SEE PLAN FOR <br />CONNECTIONS <br />INFO. <br />RUSS/ <br />A1qTOP WP <br />YSEE PLAT <br />MIN. (2) 2x8 #2 SYP <br />HEADER. SEE Q/S4 FOR <br />REQ'D CONNECTIONS <br />2X4 #2 SPF STUDS @ <br />12" O.C. W/ USP SPT22 <br />@ BASE & S PT24 @ <br />TOP <br />2X4 #2 SYP P.T. PLATE W/ <br />V EPDXY ANCHOR OR <br />J-BOLT OR Y2 TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />MIN.6 EMBEDMENT i <br />MAIN HOUSE <br />SLAB <br />(2) #5's CONT. T&B <br />W/ #3 STIRRUPS AT <br />4'-0" WHEN DEPTH <br />EXCEEDS 30" <br />GARAGE MONO/ 21 <br />en <br />N <br />N <br />Z <br />d� <br />W <br />¢� <br />d <br />m x <br />V- <br />s+- 6 ®- <br />.yco CP : <br />N (G <br />.1 <br />u ` o <br />a � co <br />cc :m <br />� J <br />M <br />N <br />0 <br />N <br />0 <br />- - <br />- aA. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />rA <br />W vE <br />a 8 <br />0 <br />0 N C) N m <br />1. 1y 0 �z� <br />0) <br />N ANo R <br />ZW <br />Q Qj M V LL <br />�� u <br />u_ Li <br />CU J j_ 0- <br />Lu <br />Z m c °) a vYi <br />o <br />y O <br />W a m-_; 2 <br />z 00 <br />Q <br />Lo Z <br />J <br />N O 3 �um <br />- <br />Z <br />W ❑ ❑ <br />z N M <br />o'o <br />N <br />z o � <br />Q <br />CI- <br />V) z <br />Q) ( o <br />LL <br />W <br />O u, o <br />V) �v N <br />Ln <br />wal. <br />co <br />w <br />� J <br />- N p <br />law Z <br />4 I <br />C N <br />U o 0 <br />ry co <br />o <br />z <br />w <br />M <br />0 <br />Z <br />Q o <br />zo <br />o <br />>N <br />Z® <br />4 <br />E V <br />oa <br />I�° ro <br />o E <br />o¢ <br />o <br />0o <br />o <br />oa <br />co <br />v <br /><z <br />s <br />Qo <br />wz <br />�J <br />f <br />C <br />c <br />¢ <br />am <br />mo <br />OLL <br />Z <br />z <br />m J <br />s <br /><� <br />aw <br />ZZ <br />o< <br />ga <br />W <br />c/ <br />T � <br />o <br /><0 <br />?� <br />z <br />a�w <br />Fk <br />� <br />=3 <br />o <br />Jz <br />wa <br />C9 r <br />7 <br />;o <br />M <br />V <br />Ica, <br />5- <br />d i <br />h <br />C <br />� 2+ <br />00 <br />= <br />)CD <br />J <br />Ln <br />p <br />ry <br />rn <br />N o <br />0 Y o <br />N <br />m <br />U)LO <br />N <br />a-.+ <br />O LL <br />N <br />� N <br />m <br />O� <br />o <br />Lid <br />r <br />co N <br />r <br />E <br />c M <br />O <br />z <br />ca <br />N <br />E <br />m <br />CU a <br />U 0 <br />Q <br />JOB <br />NO : 23-04901 <br />SCALE: AS NOTED <br />SHEET NO. <br />D 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.