My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6732 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6732 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 6:56:41 PM
Creation date
2/28/2025 11:09:33 AM
Metadata
Fields
Template:
Building Plans
Street #
6732
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6518
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
III III II 11.II0111 nn,- [l <br />STAIR CALCULATIONS: <br />TOTAL RISE= 1U-0 3/4" <br />B <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />USP MP3 CLIP EA. <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />16 rgv <br />i15 <br />,4 <br />,13 <br />M <br />Z12 <br />i <br />42" KNEE WALL WITH 011 1 <br />1x8 CAP & CASING -10 <br />ig <br />�o <br />B i8 <br />STORAGE00 <br />GRASPABLE <br />UNDER <br />RAILING -"7 <br />STAIRS <br />00 <br />i6 1x TREAD <br />1x8 CAP & , <br />i 5 (TYP.) <br />CASING i4 1x RISERS <br />(3) 2x12 (TYP') <br />3 <br />STRINGERS 2 N 2x FRAMED <br />2x FRAMED <br />WALL <br />WALL <br />1 - <br />- <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)-1/4"x 3 1/2" TAPCONS @ <br />16"o.c. AND 3" FROM EA. END. <br />rIN <br />T <br />SIN <br />r <br />CONT. HANDRAIL <br />42" KNEE WALL RETURN TO <br />WITH 1x8 CAP <br />& CASING WALL DETAIL <br />_� DDEEPLYWOOD CKING <br />FLOOR SYSTEM SCALE: NTS <br />25'-0" <br />12'-0" 9'-6" T-6" <br />1 31-5" 514" 01 <br />D2 <br />H1 6 H1 0 6 <br />TYP. @ 25 SH D2 25 SH D2 <br />CONERS <br />L t � 2X6 WALL EGRES <br />TYP. STAIR SECTION. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height - <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding''/z inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 318 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />SEE PLAN FOR LANDING DEPTH I <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM 0 <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENE <br />LANDING FOF <br />STRINGERS 7 <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />3 <br />D2 <br />SIM. w/(1) <br />MSTAM36 <br />FLAT STRAP <br />J <br />S6 <br />TYP. <br />SIM. w/ (1) <br />MSTAM36 <br />FLAT STRAP <br />DRYER VENT- <br />THRU ROOF. <br />HANSON BOX @ <br />36" A.F.F. <br />LAU N <br />8'-0" FLAT CLG. <br />TILE <br />TB 60" X 36" <br />- <br />SHOWER <br />16'•4" <br />FIBERGLASS <br />SURROUND <br />T-4" TP <br />-- --51-5 =-- <br />OWNER'S <br />BATH _. <br />SUITE <br />--I ' <br />'FLAT L.G.0_ 2668 <br />T-O" FLAT CLG. N <br />2068� <br />TILE ^ <br />_� <br />CARPET io <br />_Bf <br />G.T. - - - r <br />4SH <br />30 <br />Co o <br />_2668---4 - <br />+I <br />@jLID. <br />uw M 42" HIGH 1/2 <br />w <br />c WALL W/ 1x <br />m W CAP <br />2668 <br />CHAS/E <br />BEDROOM 3 <br />8'-0" FLAT CLG. <br />U) m - CARPET <br />Ca 00 ' <br />IX rp in i <br />I <br />t <br />SI G.T. - <br />4" 10'-4" <br />F- I cn <br />I I I I I I J I I I I I I I I <br />I I a <br />I I I I I I I I I I I I I 00 <br />611 114113!12111110 9 18 1 16 15 14 13 12 11 N <br />24 SH <br />co0o /\ 22 H 1 g 4 I <br />N i 01 O D2 <br />1 <br />T-811 8'-0" in 21411 <br />10 Of <br />4068 BF <br />BEDROOM 2 _ <br />8'-0" FLAT CLG. j <br />ca <br />CARPET I� <br />I I I <br />I <br />1 22 I I <br />D1 I I <br />co 4068 BF I I <br />1----- ------ <br />I I <br />I <br />25 SH <br />D2 EGRESS 22 <br />I H1 D1 I <br />I I <br />I I <br />I I <br />I ' <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L-------------------------------------- <br />i <br />-2" <br />11'-01, <br />SIM. w/ (1) <br />MSTAM36 <br />FLAT STRAP <br />N <br />00 <br />N <br />N <br />0 <br />1 <br />i" <br />0 <br />60 <br />1400 <br />RFV 10-1-20 CAR <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-01, <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.* <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT, <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS** <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 <br />S. H. <br />13 <br />20 X 38 J <br />18 z X 37 <br />S.H. <br />14 <br />20X50J <br />182X50 <br />S.H. <br />15 <br />20 X 63 <br />18 X 62 4 <br />S.H. <br />16 <br />20 X 72 <br />18 X 714 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />1H3 <br />271/4X38 <br />26x374 <br />S.H. <br />1 H4 <br />27 4 X 50 � <br />26 x 50 <br />S. H. <br />1 H5 <br />27 J X 63 <br />26 X 62 112 <br />S, H. <br />1116 <br />277X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 4 X 25 1/2 <br />S. H. <br />23 <br />37 J X 38 i <br />36 } X 37 314 <br />S. H. <br />24 <br />37 J X 50 J <br />36 4 X 50 <br />S. H. <br />25 <br />37 J X 63 <br />3671 X 62 1/2 <br />S. H. <br />26 <br />37 J X 72 <br />36 J X 71 1/2 <br />S. H. <br />DOUBLE 2 WIDE <br />75" TALL <br />733 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 4 <br />S. H. <br />33 <br />54 X 38 J <br />52 4 X 37 3q <br />S. H. <br />34 <br />54 X 50 J <br />52 4 X 50 <br />S. H. <br />35 <br />54 X 63 <br />52 4 X 62 7 <br />S. H. <br />36 <br />54 X 72 <br />52 4 X 714 <br />S. H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />RAG <br />(2) - 2X4 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />Follow Q/S4. See Plan for <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE"C" <br />OA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />+28.3 / -30.8 <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />® <br />+26.6 / -33.5 <br />SEE SN SHEET O SEE SN SHEET <br />'� 40 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />SECOND FLOOR PLAN - B <br />SCALE: X"=V-0" <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090 <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />n p p <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'41 A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR LIVING AREA 721 S.F. <br />2ND FLOOR LIVING AREA 807 S.F. <br />TOTAL 1528 S.F. <br />GARAGE 397 S.F. <br />LANAI 60 S.F. <br />ENTRY 30 S.F. <br />TOTAL SQ. FT. 2015 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/13-13 KRAFT FACED <br />(GARAGE / LIVING) <br />0 <br />O W <br />--omx <br />W C9 Id <br />y -0 N <br />N p rp <br />a E= <br />3 �- <br />cu ffi <br />'als ro <br />c E <br />� v <br />Cl- <br />M <br />GV <br />0 <br />CV <br />N <br />0 <br />C i' <br />0 <br />I.w <br />106 <br />a . <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />a <br />�E <br />0 <br />0 <br />6 s <br />.5 - om <br />7 <br />W <br />? <br />tnF- I a <br />a <br />N OIt <br />co V <br />C <br />-� l W <br />J LL n- <br />p <br />Z' <br />C13 <br />Lu <br />N -, a 2 <br />v Z <br />I% <br />Jr- <br />Y� hoL <br />� 0rn o <br />W <br />Z <br />ILc <br />� rNi Z a <br />N <br />a � o <br />o� <br />Z <br />L) co <br />W <br />❑ ❑ <br />M � <br />z N M <br />0 <br />Z N <br />z � � <br />N <br />M <br />z <br />`o <br />0 <br />(� <br />w <br />-� <br />O <br />tff <br />w <br />Of <br />U <br />w <br />2 8 <br />U a y <br />o <br />¢ � o <br />N � <br />o <br />J <br />Z <br />W <br />M <br />M <br />z ¢ <br />Z <br />L-'- <br />E <br />cdE <br />z <br />oz<o <br />cd- <br />U <br />z <br />oa <br />!� N <br />o <br />o E <br />�0 <br />&a <br />Uo <br />o <br />0< <br />t <br />o <br />wo <br />Z <br />�� <br />_� <br />L <br />�� <br />� ro <br />< o <br />Imo <br />w 2 <br />Z K <br />m J <br />m <br />¢ w <br />5 <br />w <br />'2 <br />�z <br />J <br />A� <br />°< <br />az <br />1, 1, <br />W <br />m <br /><o <br />Qa <br />J <br />o <br />C10 <br />=IQ <br />;o <br />o I <br />=O <br />0 <br />= <br />B <br />m <br />0 <br />M <br />CID LO <br />TT <br />LO <br />•� <br />N <br />o <br />o <br />N <br />� U <br />O <br />ILL <br />r1%1 <br />Y <br />c <br />N <br />m N <br />O <br />L O <br />C4 <br />Liz <br />CV fVIr- <br />co <br />r <br />E <br />c (� <br />cc L <br />z <br />z <br />E s'- <br />» <br />E <br />`m <br />a <br />E <br />o <br />() ° <br />¢ o <br />JOB <br />NO: <br />23-04901 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.