6810 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6810 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:07:42 AM
Creation date
2/28/2025 11:09:41 AM
Metadata
Fields
Template:
Building Plans
Street #
6810
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6509
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4"-1" CROWN) <br />WALL SHEATHING <br />STAPLES @ 6" O.C. VERT BETWEEN ::.I I rlAx16GAx1-1/2" LONG (3/4"-1" <br />STUDS (NOTED THUS:—) - OFFSET I I I I t I CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF U <br />HOME H C G <br />GARAGE SIDE O 0 0 <br />5'-0" <br />�- <br />STUB -OUT FOR 1'-O" 0 9 0 <br />GAS METER 0 o <br />N _ <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'4- <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8l1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8l1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONE <br />(Not required if both loe <br />Filler <br />1/8" gap <br />FILL CELL STD, 90° HOOK BOND BEAM <br />11 <br />v7 <br />w CONT. #5 <br />a STD.90° <br />BAR T. #5 I HOOK <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND !I <br />SHEATHING PER PLAN <br />CONNECTION <br />_ <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />r <br />1/8" min. Small 2" min. <br />2" max. } <br />gap 4" max. <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series <br />_ <br />Depth 1 End Intermediate <br />® <br />2-8d 2-8d <br />Ai <br />BCI5000s <br />11-718"i <br />2-8d-_' <br />3-8d <br />148d <br />5-8d <br />Clinch nails <br />-- <br />9-1/2" <br />2-8d <br />2-8d <br />when <br />:BCl6000s® <br />11-7/8" <br />2-8d <br />3-8d <br />possible <br />BCI 6500s®— <br />14" <br />16" <br />2-8d 5-8d <br />2-8d 1 6-8d <br />I <br />1) Support back of web during nailing to prevent damage to j -7/8" Z-8d 3-8d <br />web flange connection. ' BCI 60s® 14" 2-8d 5-8d <br />2) Block solid between joists for full length of span. Tight fit 16" 2-8d 6-8d <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. \ 11-7/8" 3-16d 3-16d <br />2x4/Plywood/OSB web stiffener 2" min. BCI 90s® 14" 5 16d 5-16d <br />4) Place joists together and nail from each side with 2 rows of 10d nails 4" max. � <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or 16' 6-16d 6_16d <br />OF THE JOIST ASA REQUIRED LEAVING Y" GAP TOP sides b 6". -Hangers with side nailing. <br />8 @ y - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION <br />- Birdsmouthcuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. hi her than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />1/16 <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o-c. <br />Provide adequate bearing <br />for each lapped joist. <br />10dnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />9 <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer y Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or 1 <br />beam below Load bearing wall must stack over _ _ <br />blocking and wall or beam below.* — — <br />Joist <br />When joists meet over wall, provide <br />134 <br />/" minimum bearing for each. I Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />WIM <br />6A 1 2" ROUND HOLE MAY 6� 6 DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Yz" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yz" <br />, <br />8 <br />T-a' <br />1'-1" <br />1' 2" <br />1'-2" <br />V-3" <br />1-3" <br />T-T' <br />T-11 " <br />7-4' <br />3'-2' <br />3-7- <br />12 <br />T-9' <br />V-1" <br />T2' <br />1' 2" <br />T-3" <br />1'-9' <br />2'-4" <br />2'-11" <br />3' T' <br />4' 2' <br />4'-9" <br />6 4' <br />Any 16" joist <br />Span (it} <br />16 <br />1'4Y' <br />T-1" <br />V2' <br />1-2" <br />1' T' <br />2-6 <br />3'-2" <br />3'-10" <br />4'2' <br />S'-T' <br />6'-0" <br />T2' <br />20 <br />1'-0" <br />T-1" <br />1'2' <br />1' 2" <br />2'-0" <br />3'-0' <br />4'-W <br />4'-10" <br />9-11" <br />6'-11" <br />7'-11" <br />8'-11'. <br />24 <br />1'-0" <br />1'-1" <br />1'2' <br />1'-3" <br />2-0 <br />3'T' <br />4'-9r' <br />5'-10 <br />8'-4" <br />9-6 <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Joist hanger <br />SIMPS( <br />w/(22)' <br />NAILS 1 <br />5/8"0 <br />THRU <br />BOLT <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />NIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) — <br />Nail with 10-10d nails. =1 11= �_ <br />Install tight to top flange. SLEEVE THRU STEM <br />°. <br />SEE PLAN FOR °. • . • <br />FOUNDATION INFO ` a ° d' <br />STEM FOUNDATION <br />Filler block. <br />\ Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />r 1/4"-2" gap___�l <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />eel <br />D 0. pX Joist <br />T`de depth <br />a,�o� <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE REINF. SEE PLAN <br />n <br />1=III=11''— <br />d da IIIIaII III-i, <br />11— • v a _ <br />t (2) #5 REBAR <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />-�� LOCATION OF <br />° SECOND H10A <br />SIMPSON H10A ° ° , (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" v <br />CENTERED @ PIPE , <br />PENETRATION <br />r O O <br />d • <br />III—��I d d: O <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />—\ <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />d L <br />d <br />z <br />io • ° • <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />o <br />SEE FND. PLN. <br />SIZE & REINF. <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />40. di 44 L <br />N <br />N <br />h <br />r <br />c <br />G W <br />e- <br />=-�mx <br />m ea A <br />4A y co <br />N <br />o, <br />d <br />•� Ca G <br />o - a <br />3i <br />W <br />Rd. <br />.�+ o C O <br />y N � T <br />c E <br />A O <br />-ti <br />L <br />0 <br />IzV <br />cc <br />T:;t <br />W <br />r <br />tt�lt•dttZ�,t <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />W <br />t- <br />E <br />O M 8 <br />co(0 C N00 <br />00 <br />0) <br />��� a� <br />= u- W <br />U <br />Ia11 <br />V <br />Z <br />_ <br />_J LL <br />W a <br />-v o <br />C29 <br />i� <br />L. O <br />7 (5 N (e <br />to <br />w <br />��° °' mIL <br />IL <br />N N Z <br />OU 0 W <br />Z <br />W <br />❑❑ <br />Z N � <br />z � $ <br />10 <br />Z n <br />U) <br />V) <br />- N <br />c7 <br />o <br />zC72 <br />a--+ <br />u, <br />W <br />� p <br />U <br />OLu <br />g <br />N <br />c <br />�_U) <br />� <br />U g <br />w <br />E <br />UI <br />oc <br />00 <br />C <br />0 <br />M <br />w <br />C <br />J <br />v <br />i? <br />Z <br />Z <br />Q <br />2 <br />U_ <br />E <br />E <br />�o <br />�1 <br />o° <br />» <br /><� <br />Q <br />� CJ <br />i <br />z® <br />on <br />1— N <br />o E <br />�0 � <br />U� <br />a <br />00 <br />< <br />z <br />�, <br />o <br />W z <br />w <br />�� <br /><o <br />¢10 <br />�� <br />W0 <br />m <br />Z <br />z <br />m � <br />J <br />aw <br />�z <br />g <br />a^ <br />o� <br />=o <br />a5N= <br />W <br />KK¢h <br />KO� <br />�z <br />r <br />o_� <br />w; <br />F <br />o <br />Iiv <br />z<W <br />0 3 <br />L O <br />Lo <br />O <br />rn <br />m <br />m <br />N <br />(D Ln <br />O <br />N <br />0 <br />N <br />Cr <br />0 <br />co <br />L In <br />�i <br />lILLO <br />CM <br />.Q <br />0 co <br />O <br />LO <br />T <br />Q <br />N <br />T <br />00 N <br />E <br />N <br />CD <br />z° <br />Z <br />Oto <br />H r <br />8 <br />c <br />n <br />U _J <br />Q p <br />_J <br />JOB <br />NO' <br />23-00508 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />