Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH WALL SHEATHING <br />......... .............. ... ..... <br />..... <br />............. ..... <br />........... . ..... � I ...... ........ ........ <br />X ..... ....... . . .... ....... <br />.. ..... . ......... I . ........ . ....... <br />....... T.1 ... I., ... ... t .... <br />....... . ............. <br />..... ...... <br />V Cn ........... ...... x:v. <br />. ..... <br />. . ................ <br />16GAxl-1\2" LONG (3/4%1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN M1V 16GAxl-1/2" LONG (34-l" <br />CROWN) STAPLES@ 6" <br />STUDS (NOTED THUS:-) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:-) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" T-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />"ONLY APPLIES TO LENNAR TPA/JAX** <br />101-011 <br />TANK -LESS W/H <br />CORNER OF I I I <br />HOME H C G <br />GARAGE SIDE 000 <br />U) <br />51-011 <br />0 <br />,4 . - C) <br />STUB -OUT FOR 11-011 <br />GAS METER 0 % -1 0 LO <br />9 <br />- - - - - - - <br />- - - - - - - - - - `� - - - - - - - - - - - <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4"@ 16" O.C. <br />T-5- <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />1 Y-8" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13-91, <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />W-31' <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />V-61' <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />111-01, <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C� <br />13f_011 <br />(3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCIOJoist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x + 5/8" or 3/4" wood panel <br />1-1 /8" or two 112" <br />602.0 <br />wood panels <br />2 x + 5/8" or 3/4" wood panel <br />902.0 <br />2 x lumber <br />Double 2 x lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />4 <br />FILL CELL <br />uJ <br />STD. 90' <br />CONT. #5 HOOK <br />BAR <br />STD. 900 HOOK <br />BOND BEAM <br />SIMPSC <br />w/ (22) <br />NAILS I <br />CONT. #5 <br />BAR <br />#5 CONT. <br />5/8"D <br />THRU <br />BOLT <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />___7 BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION <br />INT. BRIG. WALL <br />N.T.S. <br />1/8" min. Small 2" <br />2" <br />gap " <br />a <br />. 4 <br />max. <br />/�7 1 ­71 - <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />Tight fit <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/PIywood/OSB web stiffener 2 min. <br />4) Place joists together and nail from each side with 2 rows of 1 Od nails <br />required when indicated or max. <br />4': <br />2x-: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING j/8" GAP @ TOP sides by 6". - Hangers with sides not containing <br />WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />DOUBLE JOIST CONNECTION - Under 2nd floor column w/ loads <br />N.T.S. <br />higher than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer 1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />0 <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />; <br />One 10d box <br />L <br />areas=20 of high <br />or�20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (1 Od) nails at 6" o.c. <br />Provide adequate bearing <br />for each lapped joist. <br />10d nails <br />SECTION INT. BRG. WALL <br />N,T.S. <br />MINIMUM SPACING 2x GREATEST <br />DIMENSION OF LARGEST HOLE <br />D <br />(KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />11 <br />L <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls for vertical load transfer __T��Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />- 7-7-j <br />F-When joists meet over wall, provide <br />13/4" minimum bearing for each. I -Joist can be offs <br />et <br />" <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series I Depth End I Intermediate <br />BCI 5000s@_i_1___7/8- <br />9-1/21, <br />2-8d <br />I 2-8d <br />__2-_8d_T <br />3-8d <br />14" <br />2-8d <br />I 5-8d <br />BCI 6000so <br />BC16500s@ <br />9-1/2" <br />11 -7/8" <br />2-8d ] <br />2-8d <br />2-8d <br />I 3-8d <br />14" <br />2-8d <br />I 5-8d <br />16" <br />2-8d <br />I 6-8d <br />BCI 60so <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI 90s <br />11 -718" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />1 R" <br />6-16d <br />6-16d <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />O— <br />-0 <br />(o El (0 <br />11 J, __ <br />1% <br />1. L?S. <br />e- <br />76"r- A %" ROUND 6" 6" <br />BE CUT ANYWHERE IN ?r <br />HOLE MAY -/ -DO NOT CUT HOLES <br />THE WEB. PROVIDE AT CANTILEVER LARGER THAN 1Y2" <br />#ROUND IN <br />7 <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY, <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES, HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL P PE AND HAMMER <br />2 1 <br />7. 1Y <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9� THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 <br />to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Joist hange <br />r <br />SIMPSC <br />w/ (22) <br />NAILS I <br />RTRUSS <br />OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />\AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)FFASTENERS <br />TYPICAL SIMPSON META12 <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC - <br />SLEEVE THRU STEM <br />WALL <br />x 4, <br />Backer block (12" wide min.) I I III III III <br />Nail with 10- 10d nails. <br />�,Install tight to top flange. <br />SLEEVE THRU STEM <br />I TI I� <br />EVE THRU STEM <br />SEE PLAN FOR <br />UNDATION INFO <br />SEE PLAN FOR A <br />9 44 <br />FOUNDATION INFO <br />STEM FOUNDATION <br />Filler block. <br />Nail with <br />10-10d nails. <br />\ <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap --- <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />Web stiffner as <br />height <br />0 requirements <br />, — - <br />Joist <br />D depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />rRADF <br />REINF. SEE PLAN <br />/-V 11- U rl A0 t: 14 t' V 1- <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META1 2 META1 2 TSS <br />INSTALLATION @ MID SPAN <br />SIMPSON H10A <br />w/ (18) 1 Od x 1 1/2" <br />NAILS <br />UPLIFT 1015# <br />TYPICAL SIMPSON H10,A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />HTS INSTALLATION <br />TOP (2) #6s x 4' 0" <br />CENTERED @ PI�E <br />PENETRATION� <br />4 <br />M <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S,P.F. <br />LOCATION OF <br />SECOND H10A <br />(WHEN <br />REQUIRED) <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />1EI I I= - <br />4,, � U1 �1 7 -111 E7 141111 <br />A T--'. <br />zi r Li 1- <br />6 71FL, —IF <br />SEE FND. PLN. <br />SIZE & REjt.� <br />12" BELOW <br />PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's X 4' 0" <br />CENTERED @ PI�E <br />PENETRATION <br />. . . . 4— . . A . <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />. ..4 <br />A <br />-\,d A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />ERED @ PIPE <br />PENETRATION PLUMBING LINE <br />Fl- <br />CENT <br />1 .0 <br />4 <br />F1 �,�_ffl <br />4 <br />HE1.1 1=1 Ell E <br />SEE FND. PLN, <br />SIZE & REINF. <br />ca <br />CS <br />.!2, cc C= <br />W C-4 <br />9 co <br />CL <br />4P <br />co <br />-t <br />cc <br />E <br />CD <br />X\0 <br />\N <br />lago <br />'i <br />0. <br />1�11 A -I, <br />1, <br />F L 0 <br />t:, <br />0 <br />0%4 <br />PESS1 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Flodda Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal, <br />W <br />EI- <br />C) co 8 <br />R4 1� 0, <br />0 C 'D <br />2 00 <br />0 -- 00 (n <br />0 <br />U) <br />Ca u- <br />UJ <br />Z ia E: <br />2 <br />C <br />i =1 9 <br />W .5.a (N <br />02,0) <br />W 65 c� of <br />Z co 6 <br />0 '< , <br />LL <br />eq _J <br />a <br />z 0 <br />W 00 <br />< <br />W <br />0 <br />(D <br />LU 10 <br />0 <br />Ln <br />V) <br />(Z J3 <br />E <br />U 0 <br />U) <br />co <br />cy�- <br />C13 <br />z <br />z <br />< <br />U_ <br />c6 E <br />-0 <br />E_= <br />00 <br />10 <br />0 <br />E <br />�0 <br />�w z <br />W <br />0-� <br />z <br />z <br />In <br />Cn <br />01 1 <br />zz <br />� 0 <br />W <br />2 3: <br />2� <br />< <br />3: <br />C:> <br />6. <br />f -- <br />x <br />co <br />-z <br />N. <br />2 <br />E2 <br />a) <br />> LO <br />C/) <br />co <br />CL <br />CU <br />> 0 <br />0 <br />LO <br />J <br />Cy') <br />C:> <br />0") <br />CO 0 <br />M <br />=3 <br />C.0 <br />Cr <br />CL <br />60 <br />cf) CL <br />-T- <br />0 00 CN <br />a) <br />00 04 <br />LO <br />'E <br />CD C) <br />(�o <br />4 <br />C,4 <br />LO <br />C.0 <br />0) T_ <br />C14 <br />Q <br />E <br />2:1 <br />0 <br />z <br />E <br />r_ <br />ca <br />a- <br />E <br />0 0 -0 cc <br />_J <br />JOB NO 22-12504-12499 <br />SCALE AS NOTED <br />SHEET NO. <br />SN1 <br />PASCO COUNTY <br />-1 1 1 1 J I I--- F_ I T <br />