Laserfiche WebLink
DOOR JAMB (REFER iX4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1 X 4 1/2"DRYWALL <br />DOOR JAMB (REFER <br />1 X 4 �1/2" DRYWALL <br />P.T. <br />TO SHT. SDW2-K1 <br />TO SHT. SDW2-K1 <br />TO SHT. SDW2-K1 <br />HT. SDN. <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />FOR DETAILS <br />1 X 4 <br />1 X 4 <br />3-1/4" LONG X 3/16"0 <br />1 X 4 <br />FURRING <br />3/16"0 X 3" LONG <br />TAPCONS <br />FURRING <br />3/16"0 X 3-1/2" LONG <br />FURRING <br />TAPCON. INTO <br />STAGGERED @ 16" <br />TAPCONS STAGGERED <br />2X8 <br />BLOCK@ SPACING ,� <br />1 <br />DETAIL <br />O.C. 2-ROWS INTO <br />1X8 P.T. <br />STAGGERED @ 16" O.C. <br />2-ROWS INTO <br />1X8 <br />PER MANUFACTURE <br />MASONRY THROUGH <br />1-1 /21� DETAIL <br />H <br />MASONRYTHROUGH <br />311 DETAIL <br />lx4 P.T. & 1x8 P.T. <br />1x8 P.T. & 2x8 P.T. <br />P.T. <br />3/16" x 3 -1/2" <br />TAPCON @ 16" <br />O.C. & 4" FROM <br />O.C. <br />1X4 P.T.— <br />x 3 -1/2" <br />DOOR JAMB (REFER <br />1 X 4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN <br />DOOR JAMB (REFER <br />TAPCON <br />TO SHT. SDW2-K1 FOR <br />TO SHT. SDW2-K1 <br />2" EDGE DIST. <br />TO SHT. SDW2-K1 <br />CONN. DETAIL <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />10d @ 12" O.C. <br />1 X 4 <br />FURRING <br />2X8 P.T. WITH 3/16"0 X 3" <br />Zx P.T. AS REQ'D <br />2X8 P.T. <br />LONG TAPCONS <br />STAGGERED @ 16" O.C. <br />2X8 <br />2x DETAIL <br />2 1/4" <br />DETAIL <br />2-ROWS INTO MASONRY <br />3-1/4" DETAIL <br />BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC <br />SCALE: N.T.S. SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45^ DIAGONAL (4)10d NAILS INTO <br />BRACE(S) 2 x 8 BRACE/ BLKG. <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHO\\\-2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL (Oj <br />SCALE: N.T.S. SS <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1 /4" MAX <br />* 2'-0" <br />BTWN.SOLID BLKG. AT TOP <br />ARCH BLKG. & BUCK � <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH 1/4" x 31/4" TAPCON (1 1/4"MIN. <br />/4„ MAX EMBEDMENT INTO <br />SOLID BLKG. AT TOP BTWN. ARCH F <br />BLKG. & BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END --�-�, <br />LEAVE A CUT OUT IN O.S.B. ON T <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />B-B ARCH DETAIL rK <br />SCALE: N.T.S. SS <br />s <br />GLASS BLOCK INSTALLATION NOTES <br />A) <br />COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) <br />ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) <br />SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) <br />SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />E) <br />INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />* PRESS PANEL REINFORCING INTO PLACE. <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />SMOOTH. DO NO FURROW. <br />F) <br />PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />G) <br />SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />REMAIN FREE OF MORTAR. <br />H) <br />STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />1) <br />AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />j) <br />APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) <br />A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />SECTION <br />A -A <br />8" <br />1/4" x 31/4" TAPCONS <br />—LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />- AT EA, END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />2'-0" 8" <br />EQUAL <br />20 ga. PANEL <br />ANCHOR <br />9 ga. PANEL <br />REINFORCING <br />(EVERY OTHER <br />COURSE) <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK- (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />4' MAX. RAD. <br />EXPANSION STRIP <br />1/4" EXPANSION BOLT (2 <br />PER ANCHOR) <br />EXPANSION STRIP <br />-SEALANT <br />6" MIN. LAP SPLICE W/ <br />REINFORCING PANEL <br />PROPER INSTALLATION MAX. 8" <br />#5 REB <br />(TYP,) <br />FILL SOLID STD. 90' <br />BOTH CELLS HOOK (1 <br />/ pz/', 7/ <br />NOTCH WEB AT <br />t5" FIRST 2 COURSI <br />CAPACITY = 945 # FOR 1 STRAP <br />=1890 # FOR 2 STRAPS <br />i-PLY PRE-ENGINEERED TRUSS <br />USP RT16M W/ (8) NA11 NAILS & (6)1" x 24' <br />TAPCONS <br />(IF TRUSS IS 2 PLY INSTALL USP HTWM16 W/ (6) <br />10d NAILS x *NAILS AND <br />(4) a' X 1 a" WEDGE BOLTS [ (1) STRAP = 1225 # , <br />(2) STRAPS 2450#)) <br />BOND BEAM OR CAST <br />IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4'Y.' WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (3) 1/4" X 3 1/2" TAPCONS AT 16" <br />O.C. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5) -12d NAILS <br />2X6 TO 2X4 , <br />6" MIN. LAP <br />SPLICE NOTE: <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />\- SEALANT <br />GLASS BLOCK DETAIL <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. <br />12 <br />SEE <br />PLAN <br />LFILLED CELL PER <br />FOUNDATION PLAN <br />+ <br />kR <br />YP.) <br />THE <br />:S <br />x <br />+ + <br />+ + <br />+ + <br />+ + <br />+ <br />/ TRUSS <br />V// <br />USP RT3A 2X4 SYP EACH TRUSS <br />CONNECTOR <br />/ SEE LINTEL- <br />SCHED. <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH —� <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" = V-0" 111"s—s <br />(1) #5 BARS CONT. <br />TOP WITH MIN. 3" <br />COVER <br />M <br />6'-0" <br />G <br />° <br />p ° , <br />p, p <br />RADE <br />° <br />P _ <br />_z <br />04 <br />•D n <br />° D <br />I_ 16" MIN, <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />F.F. <br />(2) #5 REBAR. MIN. 3" <br />COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />SCALE: 3/4" = V-0" <br />PRECAST LINTEL <br />I IAIA('f`CDTADI C IAICTAI I TInKl <br />FILLED CELL INSTALLATION H <br />SCALE: N.T.S. SS <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />* DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />(2)10d NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />aThH ,—PLYWOOD SHEATHING <br />/ BLOCKING AS <br />REQUIRED <br />TO SUPPORT <br />+ SOFFIT <br />+ + <br />____ + <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION rm <br />SCALE: 3/4" = V-0" SS <br />SFF RHPPT n2 AND <br />FOR <br />HTT16 W/ (18) -16d NAILS TO <br />STUDS & (1) - 5/8" DIA. ALL <br />THREAD ROD EPDXIED W/ <br />SIMPSON "SET" EPDXY MIN. <br />5" EMBEDMENT & 3" MIN. <br />EDGE DISTANCE <br />RETROFIT FOR MISSING MSTAM STRAP <br />SCALE: 3/4" = V-0" <br />2"x BOT. PLATE W/ (2)10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED — <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />�2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />USP HGAM10 @ 12" O.C. w/4-SDS <br />1/4xl 1/2" SCREWS INTO BAND <br />JOIST & (4) 3/16"xl-3/4" WEDGE <br />BOLTS INTO K.O. BLOCK <br />RETROFIT FOR MISSING EMBEDDED STRAP <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO <br />' FILL 1s14 COURSES <br />SOLID W/GROUT <br />e: <br />FOR CVERHANGS BETWEEN OVER 1 1/2" r <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. ," •: <br />OVERHAN "y <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4"- NO REPAIR READ. <br />1'-0" 6-0" <br />SCALE: N.T.S. <br />INISH FLOQR <br />D ],-.EINTOP <br />#5 BAR <br />1.0" p CENTERED W/ <br />D c <br />_ p 0 KNOCKOUT/ N <br />CHAIR BLOCK <br />MONO FOOTING <br />SIZE AND REINF. PER PLAN <br />AND SECTION DETAILS -I <br />CLEAN FILL I .p ° - P <br />DIRT z <br />°. [STANDARD o <br />#5 BAR IN 99 HOOK N <br />FILLED CELL - - <br />- <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. PERLAN AND STEMWALL <br />SECTION DETAILS <br />SCALE: 3/4" = V-0" <br />NOTE: IF RETROFIT FILLED CELL CONDITIONS <br />EXCEED (3) PER PROJECT, CONTACT ENGINEER OF RECORD <br />FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />CAPACITY = 945 # FOR 1 STRAP <br />=1890 # FOR 2 STRAPS <br />i-PLY PRE-ENGINEERED TRUSS <br />USP RT16M W/ (8) NA11 NAILS & (6)1" x 24' <br />TAPCONS <br />(IF TRUSS IS 2 PLY INSTALL USP HTWM16 W/ (6) <br />10d NAILS x *NAILS AND <br />(4) a' X 1 a" WEDGE BOLTS [ (1) STRAP = 1225 # , <br />(2) STRAPS 2450#)) <br />BOND BEAM OR CAST <br />IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4'Y.' WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (3) 1/4" X 3 1/2" TAPCONS AT 16" <br />O.C. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5) -12d NAILS <br />2X6 TO 2X4 , <br />6" MIN. LAP <br />SPLICE NOTE: <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />\- SEALANT <br />GLASS BLOCK DETAIL <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. <br />12 <br />SEE <br />PLAN <br />LFILLED CELL PER <br />FOUNDATION PLAN <br />+ <br />kR <br />YP.) <br />THE <br />:S <br />x <br />+ + <br />+ + <br />+ + <br />+ + <br />+ <br />/ TRUSS <br />V// <br />USP RT3A 2X4 SYP EACH TRUSS <br />CONNECTOR <br />/ SEE LINTEL- <br />SCHED. <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH —� <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" = V-0" 111"s—s <br />(1) #5 BARS CONT. <br />TOP WITH MIN. 3" <br />COVER <br />M <br />6'-0" <br />G <br />° <br />p ° , <br />p, p <br />RADE <br />° <br />P _ <br />_z <br />04 <br />•D n <br />° D <br />I_ 16" MIN, <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />F.F. <br />(2) #5 REBAR. MIN. 3" <br />COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />SCALE: 3/4" = V-0" <br />PRECAST LINTEL <br />I IAIA('f`CDTADI C IAICTAI I TInKl <br />FILLED CELL INSTALLATION H <br />SCALE: N.T.S. SS <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />* DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />(2)10d NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />aThH ,—PLYWOOD SHEATHING <br />/ BLOCKING AS <br />REQUIRED <br />TO SUPPORT <br />+ SOFFIT <br />+ + <br />____ + <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION rm <br />SCALE: 3/4" = V-0" SS <br />SFF RHPPT n2 AND <br />FOR <br />HTT16 W/ (18) -16d NAILS TO <br />STUDS & (1) - 5/8" DIA. ALL <br />THREAD ROD EPDXIED W/ <br />SIMPSON "SET" EPDXY MIN. <br />5" EMBEDMENT & 3" MIN. <br />EDGE DISTANCE <br />RETROFIT FOR MISSING MSTAM STRAP <br />SCALE: 3/4" = V-0" <br />2"x BOT. PLATE W/ (2)10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED — <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />�2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />USP HGAM10 @ 12" O.C. w/4-SDS <br />1/4xl 1/2" SCREWS INTO BAND <br />JOIST & (4) 3/16"xl-3/4" WEDGE <br />BOLTS INTO K.O. BLOCK <br />RETROFIT FOR MISSING EMBEDDED STRAP <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO <br />' FILL 1s14 COURSES <br />SOLID W/GROUT <br />e: <br />FOR CVERHANGS BETWEEN OVER 1 1/2" r <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. ," •: <br />OVERHAN "y <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4"- NO REPAIR READ. <br />1'-0" 6-0" <br />SCALE: N.T.S. <br />INISH FLOQR <br />D ],-.EINTOP <br />#5 BAR <br />1.0" p CENTERED W/ <br />D c <br />_ p 0 KNOCKOUT/ N <br />CHAIR BLOCK <br />MONO FOOTING <br />SIZE AND REINF. PER PLAN <br />AND SECTION DETAILS -I <br />CLEAN FILL I .p ° - P <br />DIRT z <br />°. [STANDARD o <br />#5 BAR IN 99 HOOK N <br />FILLED CELL - - <br />- <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. PERLAN AND STEMWALL <br />SECTION DETAILS <br />SCALE: 3/4" = V-0" <br />NOTE: IF RETROFIT FILLED CELL CONDITIONS <br />EXCEED (3) PER PROJECT, CONTACT ENGINEER OF RECORD <br />FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"X6" MIN. HOLE <br />SET BAR IN EPDXY <br />CAP TO PREVENT LEAKAGE <br />#5X6' EMBEDDED INTO <br />z <br />z <br />EXISTING BOND BEAM <br />O <br />co <br />FILL CELL FULL HEIGHT W/ <br />U. <br />W <br />NON SHRINK GROUT. <br />W <br />a <br />A <br />1 <br />~ <br />g <br />U <br />5XV EMBEDDED INTO <br />Z <br />EXISTING FOOTING <br />2-#5XV IN CONC. <br />co <br />to04 <br />FILLED CELL <br />DRILL 3/4"X6" MIN. HOLE <br />SET BAR IN EPDXY <br />'+rig: O <br />SAW CUT <br />A SECTION <br />�— EXISTING FOOTING <br />SCALE: N.T.S. <br />RETROFIT FILLED CELL DETAIL <br />SCALE: N.T.S. <br />Q <br />=w- <br />~VZ <br />D_ <br />w <br />WQp_ <br />Li <br />N <br />o <br />way <br />F- <br />o <br />>�� <br />zpuj <br />CD <br />WVm <br />W Z <br />�J <br />Lo <br />U. <br />2m� <br />ff�'fl <br />�: <br />00 <br />Lo <br />_0N <br />�{Z <br />e <br />=�z <br />O <br />Yw <br />¢ <br />HQ� <br />} <br />Q <br />,l�Z <br />(9 <br />05 <br />; <br />W <br />IL Q <br />H O w <br />Of W = <br />,��. cn I <br />- 3 <br /><' <br />_ <br />0 <br />U Q <br />I.. c , <br />Q <br />uj <br />V T <br />III <br />cl)1�..i��/k'.TYc'-O <br />uj <br />Lli <br />uj <br />X:a <br />HH <br />N E <br />C <br />W i.. �D U <br />N V �m u M <br />c: 0 u <br />0�8 b8 <br />i U <br />•— C"R a� <br />^Nl V w Q.00 - c <br />W >` <br />N <br />w <br />Lu H~ Uj D: _j w2�_0 <br />2 -AY zw Z <br />�o g �< O< m m w U O U- J O <br />Q Q U <br />F- 1 <br />= 0 z� L L <br />pr XLuO O�OOmzZ <br />v)wawv�wwwV5it <br />Q z r2 o Q H Q Q <br />U <br />0 <br />(A Z <br />�0a�ZYcl <br />��WO���_M_wo�0a. <br />� <br />owVoa <br />LL <br />oQ Q <br />OQZ Q <br />o <br />Q <br />i1 <br />O <br />N <br />Z Lu <br />0 I— <br />> cn o <br />0 M O <br />Q co Lo <br />()� a- M <br />Q>""Q00 <br />Z V F— <br />uj <br />W <br />-� <br />CO <br />N <br />O <br />04 <br />O <br />" <br />O <br />O <br />0 <br />O <br />N°' <br />E <br />Z Z <br />O <br />WU�� <br />wwv� <br />N <br />c> <br />Z <br />o--a <br />ZWI=- <br />¢ <br />W WF' <br />Q <br />=m2Z <br />Z � J <br />�I <br />>.�ZW <br />a- <br />zZW <br />p <br />Og�W <br />Q <br />Z Z <br />Z <br />Z <br />�a0 <br />U <br />a <br />OV <br />o <br />F� <br />W <br />a <br />Z <br />ss <br />Z <br />z <br />w <br />J <br />UJ <br />C�4 <br />M <br />LAST PLOT DATE <br />Oct. 10, 17 <br />O <br />STRUCTURAL <br />— <br />J <br />iDETAILS-RETRO FIT <br />