My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3245 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3245 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:19:22 AM
Creation date
2/19/2025 10:19:47 AM
Metadata
Fields
Template:
Building Plans
Street #
3245
Location
Moulden Hollow Dr
Contractor
Lennar Home
Building Plans - Permit #
19303
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6'-11" <br />LIVING <br />ROOM i <br />2'-3" <br />A� <br />N / PWDR y <br />� S � BATH GI I <br />/LINE OF <br />i FLOORS <br />ABV <br />FOYER TO 2ND <br />FLR ELEC <br />4'-0" <br />�- of GFI <br />ENTRY vuP <br />0 <br />r <br />I <br />5'-6" <br />—gig <br />-i <br />DINING ROOM <br />V-8" 4'-6" 1 -7" <br />4'-4„ <br />i �� <br />T - <br />GFI i <br />L - <br />GFI <br />_.� 4. <br />PTO <br />I !DISP <br />;REF <br />DW--GFII <br />-i4 -. 4 <br />KITCHEN <br />-FOR- <br />HOOD <br />�I <br />(V <br />GFI GFI <br />' <br />GFI <br />WH, <br />LIGHT AND ELEC`'— - <br />SWITCH IN PANEL <br />ATTIC <br />LL <br />" TWO CAR GARAGE <br />GFI <br />0 <br />GFI <br />r GFI <br />-110V CLG <br />MNT. <br />OUTLET.__. <br />I <br />of <br />0 <br />04 <br />LINE OF -- <br />STRUCTURE ABOVE <br />FIRST FLOOR ELECTRICAL PLAN <br />1 /411 = 1'-019 <br />- - A/C <br />DISCONNECT <br />-- WP <br />GFI <br />—ELEC <br />METER <br />MASTER <br />SUITE <br />CD <br />7'-3" <br />-- F -� <br />S' <br />CM <br />S <br />uuu�wvin <br />#4 <br />LINE OF ROOF <br />BELOW -. <br />LINE OF ROOF <br />BELOW <br />SECOND FLOOR ELECTRICAL PLAN <br />1 /4„ = 1 '-011 <br />BEDROOM <br />#3 <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR THE <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />2011 NFPA 70 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.1. <br />PROTECT CIRCUIT PER 2011 NEC. <br />7. IN ALL AREA SPECIFIED IN NEC 2011 210.52, ALL 125 VOLT, 15 <br />AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT <br />RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER N.E.C. <br />210.12 <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />200A INDOOR PANEL <br />CENTER <br />- - -- --♦ #15 copper to lights & outlets <br />NEMA 1 <br />�---- ---- -0, #12 copper to 20 amp dots <br />200 AMP <br />i <br />- - - -- #10-2 copper to WH <br />#10 3 copper to Dryer <br />I <br />METER <br />I <br />--- 210 or 4/0 SER Alu <br />MAIN <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED - --_ <br />-- 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />-INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />O <br />J <br />io <br />- SWITCH <br />DOOR <br />JAMB <br />4 1/2" <br />DUPLEX _ <br />OUTLET <br />TRIM ih <br />BASE — <br />TRIM `c <br />NOTE: N > o � o <br />ALL DIMENSIONS ARE FROM L . M 1 o <br />ROUGH FRAMING i, ,? N M M <br />�} E <br />�o .� <br />ELECTRICAL LEGEND: •- ° , ° <br />.0 v 13 Nq <br />NOTE:.ALL HEIGHTS ABOVE FINISH FLOOR •� i LU 0 c <br />OM <br />110V DUPLEX OUTLET AT 12 a a p 0 <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES' <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />' FOR LOCATION & TYPE <br />E� TELEPHONE OUTLET AT 12" OR AS NOTED ❑ w 0I- <br />_ TELEVISION OUTLET ATI2"-WIRE FOR W Ujo J�o���cYiQo jo <br />CABLE & SATELLITE Q Q U <ax zwwpzg�❑ILL-QQ <br />SW!% STRUCTURED WIRE OUTLET ~O ~O '0 Lu a- � � w w w N x w ¢ ❑ w <br />�OEOZYeazz'-owU,n. <br />SWITCH AT 36" �� O Z Qpw �t_P �YZ�¢❑¢ <br />ow- o D oQ <br />3 WAY SWITCH AT 36" `� a o a <br />4 WAY SWITCH AT 36" <br />PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" 00 <br />4j PUSH-BUTTON DOORBELL Z N <br />-A;- CLG MNT LT FIXTURE O W <br />Y <br />7'13,>- CLG MNT PREWIRE - FIXTURE BY OWNER W O O <br />C- SURFACE MNT FIXTURE I._7 (0CD <br />T Q co <br />WALL MNT FIXTURE a .,J <br />40W A 6" ROUND OPALEX - ALOTERNATE <br />3 i TUB/SHOWER 'USED <br />MAYBE Q W<IU) <br />4;)' 50W PAR30 NFL 6" WHITE BAFFLE USED IF a �j <br />APPROWNERVED BY <br />ti RECESS CAN OR ,LED 00 <br />8' 50W PAR20 NFL 4 MINI R z Vz < ~ _ ROUND RECESS Z <br />1050W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL J O <br />_SFr CLG FAN PREWIRE AND SWITCH <br />CM) COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />s SMOKE DETECTOR <br />�U-18- UNDER CABINET 18" <br />cS-18, SINGLE 18" FLUOR STRIP <br />-U-24- UNDER CABINET 24" <br />I <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />-= U-36 UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />I <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP �\ co <br />--- D-48 DOUBLE 48" FLUOR STRIP o <br />(V <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />CD" <br />48 48"CLG MNT WRAPPED FLUOR LIGHT ' <br />0 <br />24 - 24" VANITY LIGHTING <br />36 36" VANITY LIGHTING ' .0 <br />to <br />48" VANITY LIGHTING L <br />EXHAUST FAN/LIGHT <br />EXHAUST FAN > <br />DOUBLE FLOOD LIGHT W/ COVERS AND ' Li. Z Z <br />150W PAR 38 FL � w wLD <br />INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR (DU V > <br />CEILING MNT SPEAKER _ <br />CHIMES (DELETE W/ INTERCOM) _0 I- O a <br />WMIM <br />MASTER STATION Lo Z w M Q <br />E�7; ELEC PANEL C7 of I__ <br />VACUM OUTLET AT 12" Q 3:m O z <br />## Uj ~ t III <br />Z <br />L� 2AI� CEILING RETURN AIR (W/ SIZE) Z 3 <br />ER A/C REGISTER < Z 0 <br />THERMOSTAT Z Z U_ <br />TP SECURITY PAD C) LU a w <br />ELEC METER 0 Q �--i CO Z z <br />ELECTRICAL SPECIFICATION NOTES: Z Q O <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE Z U <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE g <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. O 0 11 <br />co <br />Q <br />z Z <br />Z <br />w <br />J <br />w C) <br />N <br />> M <br />LAST PLOT DATE <br />Oct. 10, 17 <br />Z 0 1 ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />B <br />
The URL can be used to link to this page
Your browser does not support the video tag.