Laserfiche WebLink
I <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />1 <br />COVER SHEET <br />2 <br />FOUNDATION PLAN <br />3 <br />UNIT -A 1532 FLOOR PLAN <br />3.1 <br />SALES OFFICE PLAN (OPTIONAL) <br />4 <br />UNIT-B 1516 FLOOR PLAN (NOT USED) <br />5 <br />UNIT-C 1624 FLOOR PLAN <br />6 <br />1st FLOOR BUILDING PLAN <br />7 <br />2nd FLOOR BUILDING PLAN <br />8 <br />FRONT AND REAR ELEVATION <br />9 <br />'° <br />RIGHT AND LEFT ELEVATION <br />ROOF PLAN <br />ABBREVIATIONS <br />11 <br />12 <br />FLOOR FRAMING PLAN <br />ROOF FRAMING PLAN <br />AB or A.B. Anchor Bolt <br />FIX or FXD Fixed <br />RA or R/A or R.A. Return Air <br />ABV or Abv. <br />Above <br />FUR or Fir. Floor <br />RAID or Red. <br />Radius <br />AC or A/C <br />Air -Conditioner <br />FLR SYS or Fir Sys Floor System <br />RAG or Rag. <br />Return Air Grill <br />13 <br />UNIT -A 1532 ELECTRICAL PLAN <br />ADJ or ADJ. <br />Adjustable <br />FOM or F.O.M. Face Of Masonry <br />REC or Rec. <br />Recessed <br />14 <br />UNIT-B 1516 ELECTRICAL PLAN (NOT USED) <br />AFF or A.F.F. <br />Above Finished Floor <br />FP or F.P. Fireplace <br />RECEPT <br />Receptacle <br />AHU or A.H.U. <br />Air Handler Unit <br />FIR DR French Door <br />REF or Ref. <br />Refrigerator <br />15 <br />UNIT-C 1624 ELECTRICAL PLAN <br />ALTorALT. <br />Alternate <br />FRT Front <br />REINF <br />Reinforcing <br />BC <br />Base Cabinet <br />FT or Ft. FooU Feet <br />REQD or Req'd. <br />Required <br />-- -- - - - <br />16 <br />ELECTRICAL SERVICE PLAN <br />BF <br />Bifold Door <br />FTG or Ftg. Footing <br />RM or Rm. <br />Room <br />I I F ---------- I- <br />L1 <br />LINTEL DETAILS <br />BK SH or Bk Sh BookShelf <br />FXD GL Fixed Glass <br />RND or Rnd. Round <br />BLK or BLK. Block <br />GALV or Galy. Galvanized <br />RO or R.O. Rough Opening <br />BLW or BLW. Below <br />GC or G.C. General Contractor <br />IRS, R/S, R/SH or R&S Rod and Shelf <br />BM or BIT. Beam <br />GFI or G.F.I. Ground Fault Interrupter <br />SC Solid Core <br />BOT or Bot. Bottom <br />GT or G.T. Girder Truss <br />SO or SO. Smoke Detector <br />BP or B.P. Bypass (door) <br />GYP BD or Gyp. Bd. Gypsum Board <br />SGD Sliding Glass Door <br />SN STRUCTURAL NOTES <br />SN1 DETAILS <br />S3M MONO DETAILS <br />BRG or BRG. Bearing HB Hose Bibb SH or 5h. Shelves - - I I - - - — I l S4 DETAILS <br />C Carpet HC Hollow Core SHT Sheet _ ____-.__ -__ _- _- S5 DETAILS <br />CAB Cabinet HDR or Hdr. Header SHWR or Shwr. Shower <br />CIR or Cit. Circle HGT or Hgt. Height SL or S.L. Side Lights S6 2-STORY DETAILS <br />CJ or C/J Control Joint HH or H.H. Hand Held (plumbing faucet) SPECS or SPECS. Specifications ST STAIR DETAILS <br />CLG or Clg. Ceiling HORIZ Horizontal SPF or S.P.F. Spruce Pine Fir <br />CMU Concrete Masonry Unit HS Hard Surface (flooring) SO FT or SF or S.F. Square Foot (feet) SS RETROFIT DETAILS <br />COFF or Coff. Coffered or Tray Ceiling ILO In Lieu Of SO or Sq. Square D1 FRAMING DETAILS <br />COL or Col. Column INSUL or Insul. Insulation STO Storage 00 ❑ ❑ ❑ El E] �❑ ❑❑ ❑❑ n ❑ ❑ ❑ �❑ - - <br />COMM orComm. Community INTorInt. Interior SW or S.W. Shear Wall WP WATERPROOF DETAIL <br />COMP or Comp. Compressor KANALL or K/Wall Kneewall SYP or S.Y.P. Souther Yellow Pine DE:] E:] [--J [::] EJEID PE 0 0 0 � ElLlE7 ❑ ❑ a <br />CONN orCONN. Connection KS or K.S. Knee Space TB Towel Bar PA 1.0 PRODUCT APPROVAL NUMBERS <br />CONT or Cont. Continuous LAUN or Laun. Laundry TEMP or Temp. Tempered _ 00 _ El❑ a ❑ E] Ell ❑ El _ ILO <br />a ❑ ❑ - ❑ ❑Ell 00 _ PA 1.1 PRODUCT APPROVAL NUMBERS <br />CSMT Casement LAV or Lay. Lavatory THIKN or Thik'n. Thicken = o - _ _ _ 4 = PA 1.2 PRODUCT APPROVAL NUMBERS <br />CT or C.T. Ceramic Tile LF or L.F. Linear Ft. TOB or T.O.B. Top of Block - - - - - - - _ <br />D or D. Dryer LL Lintel Length TOM or T.O.M. Top of Masonry PA 1.3 PRODUCT APPROVAL NUMBERS <br />DB Door Bell LT LaundryTub TOP or T.O.P. Top of Plate <br />DBL or Dbl. Double MAS or Mas. Masonry TP Toilet Paper Holder UNIT -A 1532 UNIT-C 1624 UNIT-C 1624 UNIT -A 1532 PA 1.4 PRODUCT APPROVAL NUMBERS <br />DCF Decorative Cementitious Finish MAX or Max Maximum TR Towel Ring SH1.0 HURRICANE SHUTTER PRODUCT APPROVAL <br />DEC or Dec. Decorative MC Medicine Cabinet TRANS WOW or Trans. Transom Window <br />DED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TYP orTyp. Typical SH1.1 HURRICANE SHUTTER PRODUCT APPROVAL <br />DIA or Dia. Diameter MGT Management (room) UC or u.c. Under Counter <br />SH1.2 HURRICANE SHUTTER PRODUCT APPROVAL <br />DISP or Disp. Disposal MIN or Min Minimum UCL Under Cabinet Lighting <br />DISTor Dist. Distance MIR or Mir. Mirror LINO or U.N.O. Unless Noted Otherwise 4 UNIT TOWNHOMES SH1.3 HURRICANE SHUTTER PRODUCT APPROVAL <br />DMF Decorative Masonry Finish ML or M.L. Microlam V orv. Valve (shower or tub/shower) SH1.4 HURRICANE SHUTTER PRODUCT APPROVAL <br />DS or D.S. Drawer Stack MONO or Mono Monolithic VB Vanity Base <br />DTL Detail MIN or MICRO or Micro. Microwave VERTorVert. Vertical (A C C A) SH1.5 HURRICANE SHUTTER PRODUCT APPROVAL <br />DV or D.V. Dryer Vent NTS or N.T.S. Not to Scale VL or V.L. Versalam <br />DVP or D.V. P. Diverter Valve (plumbing) OE or 0. E. Owner's Entry VTR or VTE Vent through Roof / Exterior <br />DWorD.W. Dishwasher OPNGorOpn'g. Opening Worw Washer MEAN ROOF 15 FT. HIGH TYPICAL <br />EA or Ea. Each OPT or Opt. Optional W/ or w/ With <br />ELEC or Elec. Electrical PC Pull Chain WA or W.A. Wedge Anchor FOR SINGLE STORY HOMES <br />ELEV or Elev. Elevation PED or Ped. Pedestal WC or W/C or W.C. Water Closet (toilet) <br />EQ Equal PH Phone WDorWd Wood MEAN ROOF 30 FT. HIGH TYPICAL <br />EWorE.W. Each Way PKTorPkt Pocket (Door) WOW HDR orWDW.HDR. Window Header FOR 2 STORY HOMES <br />EXP or Exp. Expansion PL or P.L. Parallam WH or W.H. Water Heater <br />EXTorExt. Exterior PLF Pounds per linear foot WIC or W.I.C. Walk-in Closet THIS DRAWING AND DESIGN IS VALID <br />FBC Florida Building Code PLNT SHLF or Pit. Sh. Plant Shelf WM or W.M. Wall Mounted (plumbing fixture) FOR 12 MONTHS AFTER THE DATE IT <br />FDN or Fdn. Foundation PLT HT or Pit. Ht. Plate Height WP Water Proofing) IS SIGNED AND SEALED OR WHILE <br />FFB Finsh Floor Break PSF Pounds per square foot WS Water Softener CURRENT CODE IS VALID <br />FG Fiberglass (Shower Pan) PT or P.T. Pressure Treated WWF Welded Wire Fabric(Mesh) CODE REFERENCES ARE SUMMARIES <br />FIN Finished PW or P.W. Pre -wire <br />FIN FLR or FF or Fin. Fit. Finished Floor PWDR or Pwd. Powder Room REV. 06.23.22 OF CODE SECTIONS. <br />PLAN REVISIONS SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />DATE VERSION DESCRIPTION Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />05-21-16 1.00 NEW BUILDING CONFIGURATION documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />2 017 F B C CODE UPDATE review all the information contained in these documents, prior to <br />1 2-2 Q V-1 7 2.00 the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />UPDATED PER F D S REVIEW undetected and not reported to the Designer /Engineer prior to <br />06-27-1 7 2.01 construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />12-19-20 3.0 FBC 2020 CODE UPDATE Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />E N G . REVISIONS PER TRUSS E N G . Payments will be made in accordance to the terms of the <br />02-16-21 4.0 agreement. <br />06-15-21 4.1 STAIR SECTION REVISED PER C.M.Control of Construction site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />10-10-22 5.0 REV. ELEVATIONS PER C.M. any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />UNIT TH (1532 1624 debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. <br />1 NEI <br />1 <br />N <br />O <br />N <br />am <br />c� <br />C <br />c+ cc ra <br />�- f E <br />�, ay <br />M <br />V-) - <br />/r <br />O <br />N <br />O <br />�- ?AU N <br />v <br />c T f, E: C F: 4� � <br />rt�.'iditRi�'EM1 <br />To the best of the Engineer's knowledge, information and belief, <br />the stnrctural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W E <br />Q 8 <br />N O <br />iN„ OD � _ OrD <br />C m $ r <br />0 <br />•--r LL W <br />LL <br />,n U u- 2 <br />= m c 0' a <br />t;°o_ 13 <br />19 0 <br />(p N 0 <br />0 <br />-�Q Of m W <br />'T. W N O Q r <br />u� F <br />ILW <br />V N <br />0 . 6 � 0 <br />= <br />W 013 <br />CD <br />V <br />z <br />zCID <br />Q <br />J <br />a <br />N <br />(I)VI <br />- <br />z g <br />�4-1 <br />-1LLJo <br />L <br />U <br />O w s <br />N <br />�N <br />(6 � in <br />U <br />� <br />a <br />r <br />m <br />U o � <br />c <br />Q Y <br />° <br />- Id <br />N OD <br />o <br />w <br />Mti <br />Cl) <br />Z <br />Q� <br />U- <br />L E <br />C1 <br />w° <br />� <br />Qo <br />�® <br />o a <br />coUo <br />0o <br />Z <br />X U <br />K< <br />Q 0 <br />w <br />o0 <br />N <br /><S <br />W <br />-2 <br />� L <br />rp <br />ao <br />U <br />y <br />ing <br />o <br />oLL <br />Z <br />Z <br />Q) <br />N Qi <br />J <br />m <br />Fro <br />Q W <br />Z <br />o <br />o <br />Z <br />ao <br />W <br />a <br />�w <br />J W <br />0_ <br />�I� <br />Milli <br />o <br />CID <br />w <br />> <br />a� <br />�3 <br />z <br />c O <br />0 <br />>U') <br />ui <br />L <br />r <br />Co <br />O <br />M <br />Z O <br />N <br />_o <br />0^7 IN <br />o <br />V) o <br />00 <br />O <br />O <br />Ln <br />N <br />N <br />Lr) <br />Q T cf <br />LA-) <br />'mot <br />O <br />,-- <br />r <br />Z <br />Z <br />E Q N <br />W <br />a <br />E <br />U a cc <br />c <br />c <br />JOB <br />NO: 22-11668-11666 <br />SCALE : AS NOTED <br />SHEET NO. <br />1 _ <br />