A/C <br />DISCONNECT <br />- <br />T—LINE OF <br />STRUCTURE ABOVE <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4„ = 1'-0„ <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D), KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE S;NK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />OCT 2 8 222 <br />\P,,;\--A I <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition I/ <br />by Debra Anne Klahr PX2300 <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />NEMA 1 <br />#12 copper to 20 amp ckts <br />200 AMP <br />op <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 410 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to Tooter steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET <br />TRIM---o <br />0 <br />BASE <br />NOTE: <br />11 ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o z <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />®TELEPHONE OUTLET AT 12" OR AS NOTED <br />ELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />SW STRUCTURED WIRE OUTLET <br />E- SWITCH AT 36" <br />co <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-C PUSH BUTTON FOR GARAGE DOOR OPENER <br />— DIMMER SWITCH AT 36" <br />--fl PUSH-BUTTON DOORBELL <br />A� CLG MNT LT FIXTURE <br />TB CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />ALTERNATE <br />03 TUB/SHOWERND OPALEX - CANS MAY BE <br />4� 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />C APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />CosCOMBINATION <br />DETECTOR <br />O SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />ETT 24 -&a 24" VANITY LIGHTING <br />gi_— 36 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />If MASTER STATION <br />l� ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />® A/C REGISTER <br />C THERMOSTAT <br />© SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />�/`�,/J` E <br />W <br />0 (7 O <br />co <br />-- <br />V)U <br />} M 7 (� <br />-0-0-2 <br />A� t o <br />Y/ O 2 0 <br />O -0 Q <br />.^V) <br />U w Q,,t <br />EM <br />W <br />70v00 <br />L Q <br />a 0) . <br />LLW W <br />❑ L Ul <br />~W_jWgOP z <br />WQ2QYw <br />WO2Qaa -jOU00� 0Z <br />❑ <br />V <br />Q<_ <br />?x Q <br />Z�Q�Q <br />0�OoLLYOom0z <br />Z <br />Q <br />LL0 �a>zYo~z�W<0WOZ <br />�Oi¢�wUQ¢W <br />❑z <br />LL <br />p� <br />OW o ::) 0Qe <br />u_a <br />O <Qu- <br />O <br />O <br />[V <br />Ow <br />� O <br />aV"In <br />V) Lf)LL <br />Q W Q Ln <br />e a <br />>_ <br />Q U <br />Q 00 <br />z I— <br />W <br />W_j <br />�O <br />N <br />N <br />O <br />N <br />O <br />N <br />O <br />O <br />O <br />GO <br />00 <br />c- <br />OC7 <br />0 <br />N <br />0 <br />0 <br />O <br />N <br />O <br />N <br />O <br />( <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N. <br />0) <br />N <br />0) <br />O <br />OO <br />i <br />CD00 <br />i <br />Oi <br />N <br />M <br />i <br />O <br />� <br />CD <br />O <br />CD <br />O <br />O <br />O <br />r- <br />O <br />N <br />O <br />O <br />� <br />O <br />N� <br />` <br />� <br />0 <br />N <br />0 <br />co'4 <br />0 <br />0 <br />V71 <br />0 <br />O <br />0 <br />N <br />L <br />M (� <br />Z Z <br />O <br />V`J <br />owW <br />w1­­— <br />Q O <br />Q <br />Vo�o <br />�Q <br />a. <br />Oa=Q <br />~mOZ <br />(=I <br />�./ <br />0 !z w <br />Z > J <br />> <br />a <br />� <br />Z � <br />r—I <br />f1 <br />Z z <br />0� <br />W <br />OU��W <br />>_ O <br />Z to <br />Z T'i <br />�QO <br />ry _�2 <br />Z <br />V <br />g <br />OU <br />O <br />co <br />Z <br />Z <br />z <br />w <br />J <br />W:14 <br />N <br />@ <br />LAST PLOT DATE <br />>O <br />Jul. 15, 22 <br />z 0 <br />1ST & 2ND FLOOR <br />J <br />ELECTRICAL PLAN B <br />