Laserfiche WebLink
0 <br />s <br />ma FOLD UP WEATHER <br />RESISTIVE BARRIER & WEATHER RESISTIVE WINDOW UNIT <br />a TEMPORARILY SECURE BARRIER <br />DOOR ROUGH OPENING <br />IR <br />WEATHER SLOPE <br />0.3 in: 12.0 in <br />RESISITIVE <br />BARRIER <br />c WOOD FRAME CONSTR. <br />-_ -- 0.6 cm : 30.5 cm <br />N ( ) <br />TAPE :':r._.. EXTERIOR <br />--- SELF -ADHERED FLASHING:::;:::;:;:;':::'`' 3/4"-1" BEAD OF CONSTR. <br />SHEATHING <br />s . BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND RETURN <br />5,M <br />UP JAMB 6 . USE LIQUID NAIL BRAND <br />WALL BY 6 IN. A; Q EXTERIOR <br />^ (ASSEMBLEDPANDOW) � s ' '` OR EQUAL WEATHER PROOF CAULKING <br />7S <br />_ __- CEMT. FIN. <br />42 A <br />- - ��;�:Et=='gym"� ®- - <br />-- _ WEATHER - _ _-- _ - BUILDING PAPER <br />a _ ELF -ADHERED FLASHING S <br />RESISITIVE _- <br />BARRIER SEAL TOPS OF JOISTS WIRE LATH <br />q.. <br />-- - - - - 1 <br />- r UNDER DECKING SUBF L <br />. _. OOR <br />---- (SEE DETAIL WP07)•Y.. s <br />• • ' <br />-----______ SELF -ADHERED FLASHING.. <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive RIM JOIST <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under 1 1 <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head 2 2 O <br />flashing and seal with tape <br />a <br />SELF -ADHERED FLASHING Scale: NTS SELF -ADHERED FLASHING SELF -ADHERED FLASHING WP03 <br />r FLANGED WINDOW WP01 EXTERIOR DOOR WITH DECK - SECTION A WP02 CEMT. FINISH SILL/ POTSHELF/CHIMNEY SHOULDER <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />U) <br />EXTERIOR SHEATHING MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />" 3/4"-1 BEAD OF CONSTR. NEEDED IN CORNERS ADHESIVE <br />EXTERIOR SHEATHING INSTALL SELF -ADHERED THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />J _ ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD FLASHING <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE SELF -ADHERED FLASHING <br />FLANGED WINDOW _-- <br />= UP JAMB 6". USE LIQUID NAIL BRAND <br />SEE DETAIL P01 <br />m OR EQUAL WEATHER PROOF CAULKING W=-- - _ - <br />a <br />REFER TO TECHNICAL -- <br />SCORED <br />LETTER ON CHEMICAL =- <br />o o <br />RELEASE PAPER <br />COMPATIBILITY <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING, <br />(BEFORE FOLDING, SCORE <br />EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />VERTICALLY FROM <br />BOTTOM OF <br />O <br />... <br />1 <br />................................. <br />...................................... THRESHOLD <br />SECTION -A (SEE DETAIL WP02)-� <br />DO NO <br />BOTTO <br />FLANG, <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />NOT USED <br />4SHING <br />WP04 <br />E <br />AM <br />WP07 <br />WP10 <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />0 <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />WP05 <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />WP1 1 <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />44 2 <br />° ' ad <br />a: <br />a <br />Foundation Wall° <br />a. <br />d. <br />v n <br />FOUNDATION WEEP SCREED <br />WINDOW FAS' <br />DECORATIVE <br />CEMENTIOUS <br />STUCCO LIKE <br />CAULK OUTSI'. <br />EDGE OF <br />WINDOW BUC <br />CAULK AREA I <br />WINDOW FRA <br />ACROSS WIN[ <br />BUCK AND EX <br />TO MASONRY <br />CAULK JOINT <br />BETWEEN <br />"STUCCO" ANI <br />WINDOW FRA <br />CAULK WINDC <br />FRAME TO <br />WINDOW BUC <br />ALL THE WAY <br />AROUND, EVE <br />WINDOW SILL <br />6 POINT CMU WINDOW CAULKING <br />2 <br />5 <br />4 <br />6 <br />7 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />MASONRY BLOCK <br />BACK CAULK <br />WINDOW BUCK <br />TO MASONRY <br />CAULK INSIDE <br />EDGE OF <br />WINDOW BUCK <br />WINDOW FRAME <br />ANY SCREWS IN <br />BOTTOM OF <br />WINDOW SILL <br />SHOULD BE <br />CAULKED BEHIND <br />THE FASTENER <br />WP121 <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW <br />GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as# in each detail that corresponds <br />to the numbered items in theist of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water <br />shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on <br />demand, embedded in the adhesive layer) - for ease of <br />installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions <br />and adhere to substrate using a square piece of flashing <br />material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing <br />accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />Note: <br />The building paper and metal lath must b.: <br />installed over the top of the weep screed. <br />- 7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />FLASHING REQUIREMENTS <br />R612.12 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows <br />shall comply with Section R703.8. <br />R7 3.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt free from hoes and <br />0 st i s eat g p pe y p I <br />breaks complyingwith ASTM D 226 for Type 1 felt or other approved water -resistive barrier <br />YP pp <br />shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be <br />applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 <br />mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other <br />approved material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as <br />described in Section R703.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a <br />manner to prevent entry of water into thewall cavity or penetration ofwater to the building <br />structural framing components. Self -adhered membranes used as flashing shall comply with <br />AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved <br />corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall <br />extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent <br />drainage. Flashing at exterior window and door openings shall be installed in accordance with <br />one or more of the following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with <br />projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame <br />construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.15 Drained assembly wall over mass assembly wall. Where wood frame or other types of <br />drained wall assemblies are constructed above mass wall assemblies, flashing or other <br />approved drainage system shall be installed as required by R703.8. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1 /2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />O <br />N <br />N <br />�- <br />C_ <br />CU <br />O <br />CZ <br />-0 <br />0-- <br />- <br />Cl) <br />-�-+ <br />N <br />U <br />cn <br />O <br />© <br />'� <br />-O <br />LL <br />- <br />(10 <br />O <br />(!) <br />Q3 <br />_ <br />d <br />CZ <br />(D <br />. ■� <br />0- <br />0- <br />0 <br />0 <br />O <br />(D <br />CZ <br />+J <br />00 <br />LU <br />Q <br />z <br />Z <br />Q <br />J <br />a <br />SHEET NO. <br />WP <br />1.0 <br />