39774 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39774 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:39:54 AM
Creation date
2/19/2025 10:22:05 AM
Metadata
Fields
Template:
Building Plans
Street #
39774
Location
Harmon Grove Ct
Contractor
Lennar Homes
Building Plans - Permit #
1230
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />W <br />5'-6" <br />DINING ROOM <br />4'-4" 1'-7" 4'-6" <br />REF <br />1'-8" N <br />u; <br />ML- <br />i <br />pp er <br />;4� <br />KITCHEN <br />FOR <br />. <br />HOOD <br />A <br />3 Oo 0 <br />0 <br />`V <br />GFI <br />HW <br />GFI <br />O <br />ELEC �-PANE <br />L <br />TWO CAR GARAGE <br />i <br />i <br />0 <br />GFI `4 <br />GFI 110V CLG <br />MNT. <br />— OUTLET_ — <br />— — — — — — — — — — — <br />I i I <br />I � I <br />01 <br />� i I <br />i <br />/ — — — — — — — <br />LINE OF <br />STRUCTURE ABOVE <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /411 = 1'-0„ <br />1 2'-3" <br />)PWDR N <br />GFI BATH �N <br />LINE OF\. <br />— FLOOR I <br />ABV <br />------ /. <br />GFI <br />------ / <br />TO 2ND I, FOYER <br />FLR ELEC <br />4'-0" k / <br />C <br />GFI o <br />- — F- — —ENTRY <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-0" <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />2014 NFPA NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING <br />ROOMS, PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON <br />AN A.F.C.I. PROTECT CIRCUIT PER 2014 NEC. <br />7. IN ALL AREA SPECIFIED IN NEC 2014 210.52, ALL 125 VOLT, 15 <br />AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT <br />RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER N.E.C. <br />210A2 <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS FRO GARAGE MUST BE SERVED <br />BY SEPARATE BRANCH CIRCUIT THAT DOES NOT SUPPLY <br />OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR. <br />NOTES: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR <br />SIDE -HINGE DOORS SHALL BE TESTED AND LABELED <br />WITH A PERMANENT LABEL PROVIDING TRACEABILITY TO <br />THE MANUFACTURER AND PRODUCT. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />TYPICAL 150-200 AMP ELECTF <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />210 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />]CAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />io <br />SWITCH <br />DOOR <br />JAMB <br />u <br />4 1/2" <br />DUPLEX <br />OUTLET <br />TRIM M <br />BASE ° - <br />TRIM <br />T <br />NOTE: N > o o <br />ALL DIMENSIONS ARE FROM L 0 N <br />ROUGH FRAMING >1 } M <br />(n V y a <br />W 2 0 u o <br />ELECTRICAL LEGEND: MC w d . _° <br />m Q <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR i M <br />110V DUPLEX OUTLET AT 12" a o NOTE: ALL �- °' _0 O 00 a <br />^ <br />110V DUPLEX OUTLET AT 39" RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED ° w vi w O <br />TELEVISION OUTLET AT 12" - WIRE FOR W W w o M Q ¢ ¢ Y z p z <br />CABLE & SATELLITE U LU Q°R_jCO0 o �wUoLL Jo <br />Q Q V Z) 0 zU_LLazM0or¢Q <br />�O OROOm z <br />STRUCTURED WIRE OUTLET C 0 co w a w v5 w w w in LL z =o 2 <br />Cy _jQa>zY40 OwU o- <br />Ge SWITCH AT 36" z ¢ow ��V5 i32Q°¢ <br />O� o Z)° z <br />6 3 WAY SWITCH AT 36" " ¢ ° ¢ w <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />— DIMMER SWITCH AT 36" <br />[J PUSH-BUTTON DOORBELL O <br />O <br />N <br />CLG MNT LT FIXTURE z LU <br />B CLG MNT PREWIRE - FIXTURE BY OWNER O <br />SURFACE MNT FIXTURE ? t O <br />0 •M O <br />WALL MNT FIXTURE ~ M � <br />NOTE: V) LJL V- <br />O 40W A 6" ROUND OPALEX - ALTERNATE (400 N <br />TUB/SHOWER CANS MAY BE Q LLJ Q Ln <br />41 50W PAR30 NFL 6" WHITE BAFFLE USED IF a M <br />C APPROVED BY 2: ,--� <br />C RECESS CAN OR LED OWNER Q Q 00 <br />U <br />50W PAR20 NFL 4" MINI ROUND RECESS z 3 z z <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL J 00 <br />tL Uj CLG FAN PREWIRE AND SWITCH O <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />0 SMOKE DETECTOR <br />SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP co 00 00 O o 0 <br />D-48 DOUBLE 48" FLUOR STRIP �_ o 0 0 0 0 0 <br />N N N N 24 24"CLG MNT WRAPPED FLUOR LIGHT N N O' . O o0 N <br />48 48"CLG MNT WRAPPED FLUOR LIGHT NC) r CD r- <br />d ' O O <br />U& 24 -�ra 24" VANITY LIGHTING O 0 0 0 0 O <br />9;� 36 ;;;ua 36" VANITY LIGHTING g <br />N <br />48 48" VANITY LIGHTING ' r O oO O O <br />r <br />4 EXHAUST FAN/LIGHT f� N M "0 <br />O <br />® EXHAUSTFAN _ <br />DOUBLE FLOOD LIGHT W/ COVERS AND z z <br />150W PAR 38 FL w O <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR W U <br />CEILING MNT SPEAKER Q� Q V 0 <br />® CHIMES (DELETE W/ INTERCOM) 0 X w a <br />MASTER STATION � �_ Z z w H Q <br />1 ELEC PANEL <br />VACUM OUTLET AT 12" = m O Z <br />L I— = Z <br />CEILING RETURN AIR (W/ SIZE) r Z <br />® A/C REGISTER Q Z p <br />C THERMOSTAT z w <br />® SECURITY PAD LU I� O _j 2 z <br />ETt ELEC METER LU <br />Q 0 U U Z z <br />ELECTRICAL SPECIFICATION NOTES: z p <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE Z ~ U <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE -� g <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION 0 <br />O a <br />PURPOSES. M0 <br />W � <br />Q <br />Z w <br />z <br />Lu'r- <br />LAST PLOT DATE <br />Nov. 3, 20 <br />1ST & 2ND FLOOR <br />Z 0 ELECTRICAL PLAN <br />J B <br />