My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39786 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39786 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 11:21:26 AM
Creation date
2/19/2025 10:22:16 AM
Metadata
Fields
Template:
Building Plans
Street #
39786
Location
Harmon Grove Ct
Contractor
Lennar Homes
Building Plans - Permit #
1234
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. <br />11. The exterior surface of lintels installed in exterior concrete masonry wails shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcai (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load Applied horizontal load �� • O <br />Safe vertical load + Safe horizontal load — <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />8F441B/1T8F401B/1T 8RF40OB/lT 8F321B/iT <br />FORM dr GROUT SOLID <br />V <br />Q . N W <br />J <br />�U <br />O #5 BAR CONT. <br />8F12-16/1T <br />"V" LINTEL DETAIL <br />SCALE = N.T.S. <br />ZEN <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />w <br />8 <br />F 16— <br />B/ 1 T <br />NO <br />j� Z <br />�NOMINAL <br />QUANTITY OF <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL - <br />HEIGHT <br />MATERIALS <br />c-1� precast lintels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi wl <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7132 wire per ASTM A510. <br />B. Mortar per ASTM C270 type M or S. <br />#SREBAR <br />IN. <br />AT TOP <br />(1) REQ'D <br />LR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />° ° <br />° Q <br />°C.M.U. <br />° <br />#5 REBAR AT TOP <br />° ° ° <br />GROUT <br />MIN. (1) REO'D ° 4 <br />° <br />_ <br />D <br />1.1/2" CLEAR <br />e <br />° <br />< <br />J Q L <br />n <br />° <br />-45 REBAR AT <br />= N 0 w <br />O <br />BOTTOM OF <br />rn ? Lu <br />4 <br />o <br />LINTEL CAVITY <br />w 0 X w <br />-BOTTOM <br />REINFORCING <br />PROVIDED IN <br />LINTEL <br />¢ 0 iJ <br />Z LL O �u m I> D <br />¢ <br />#5 REBAR AT BOTTC <br />7-5/8"ACTUAL <br />'NOMINAL WIDTH <br />� i� �, <br />AS INDICATED <br />(VARIES) <br />cn o o <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturers specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturers specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />OF O <br />4'-6" LL 4'-6" LL <br />O <br />6-10" LL <br />LINTEL PLAN - ELEV-Al <br />SCALE: Y4°=V-0'r <br />v, <br />K <br />ccvr <br />r U <br />W <br />'• <br />Z <br />FL.p <br />r/✓� p�•�••......•••�•�� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of Me drawing pages bearing <br />Engineers signature and seal. <br />0) <br />{p pp <br />C pNp u- <br />I0f! <br />co 1— LL LL a <br />ro W N <br />Lu <br />a a <br />Z <br />CaLLLL <br />01 <br />L cc C M O O <br />�. <br />�.�N t0 Co,CO J <br />¢ <br />Z <br />LLW <br />N2"rn <br />� N Z U <br />Z <br />N OU ❑❑❑ <br />W <br />0 <br />z <br />Z n <br />Q <br />Cl- <br />0 <br />W <br />cn <br />C <br />0 <br />) V) <br />w <br />C= <br />w % <br />t <br />;I <br />_. <br />• <br />Q C11 $r <br />CD <br />M <br />w <br />z <br />LL_ <br />US <br />� RQ <br />Qa <br />o <br />E <br />Z <br />o fo <br />CD <br />0° <br />g= <br />N <br />o <br />trio <br />�w <br />m0 <br />• rp <br />C <br />z <br />ppYU <br />O <br />Zu <br />ZZ <br />N J <br />3 <br />a " <br />�i <br />° <br />g <br />U <br />aZ <br />rJ <br />ati <br />x <br />�� <br />CD <br />CD <br />0 <br />et <br />5 <br />t <br />00 3 <br />0 04 <br />= <br />m <br />J <br />> <br />0 <br />� <br />" <br />U <br />a <br />C <br />� <br />o <br />r <br />0 <br />mo <br />70 <br />r <br />c <br />= N <br />r <br />I <br />LO <br />r <br />CN <br />C) <br />° N <br />� N <br />r <br />E <br />c. <br />r <br />M N <br />e <br />Z <br />Z <br />c <br />E <br />E <br />ai TO <br />ui <br />m <br />c <br />a <br />0 _ <br />ii <br />Q a <br />� <br />JOB <br />NO: <br />20-8073 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />Z. <br />w <br />