My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39810 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39810 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 12:38:14 PM
Creation date
2/19/2025 10:22:45 AM
Metadata
Fields
Template:
Building Plans
Street #
39810
Location
Harmon Grove Ct
Contractor
Lennar Homes
Building Plans - Permit #
1457
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" Q - <br />STUB -OUT FOR 0 1'-0" o o ;� <br />GAS METER <br />d- U <br />� O <br />CV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />164" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />**SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" orp <br />5000s 1,8/1.7 <br />net <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) ° <br />Filler blocking ° <br />1/8" gap <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />FILL CELL STD. 900 HOOK BOND BEAM <br />(n <br />7t <br />STD.90° — CONT. #5 <br />CONT. #5 <br />HOOK BAR <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION TJ! TO BE CUT TO ALLOW <br />FOR BLOCKINGITJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJf PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min.) Small gap 2" min. <br />2" max <br />• � 4 max. <br />-4 <br />Clinch nails <br />when <br />possible <br />Tight fit u Q <br />2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series Depth End Intermediate <br />BCI5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />54d <br />BCI6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-$d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/ " <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />-Under 2nd floor column w/ loads <br />higher than 15001b. <br />SIMPSC <br />w/(22)- <br />NAILS 1 <br />5/81 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />1.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />r— <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />=AND QUANTITY <br />)F FASTENERS <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSONH10A (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />BLOCKING PANEL, INTERIOR <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blacking Vertical load transfer =1 900 plf max. along bearing wall TYPICAL SIMPSON META12 / TYPICAL SIMPSON MTS <br />BEARING use 3" (10d) nails at 6" o.c. Required on interior walls : -for vertical load transfer Plumbing META12 TSS INSTALLATION / HTS INSTALLATION <br />Vertical load transfer =1900 plf max along load bearing wallmeet over . Load bearing walls when load bearing -far lateral support when joists <br />all, or wall stacks directly over wall or <br />Load bearing wall must stack beam below <br />Load bearing wall must stack over <br />*Non -stacking walls over squash=20 blocks and <br />g wall or beam below.* blocking and wall or beam below.* <br />require additional � � Joist <br />consideration. Check <br />local building *11s <br />n joists meet over wall, provide <br />9 T I -Joist can be offset <br />code for appropriate 1/16" " minimum bearing for each. up to 3" to avoid PLUMBING LINE <br />details in One 10d box <br />areas=20 of high ;vor--20 sinker vertical plumbing TOP (2) #5's x 4'-0" <br />lateral load. nail each side 3" max CENTERED @PIPE PVC OR SCH40 SLEEVE <br />at bearing. JOISTS OFFSET A/C CHASE 4" PVC PENETRATION <br />SLEEVE THRU STEM <br />N.T.S. WALL e .. . <br />Provide adequate bearing I I e, � <br />for each lapped joist. Use 10dx3" nails at 6"o.c. for all r�de��blocking panel *Non -stacking wa <br />Squash block 10d nails require additional consideration. °O � _ <br />(2x4 minimum) SECTION @INT. BRG. WALL T� TI�TI�=TI� _—ITI• _ FINISH GRADE - <br />-1�1T� fTfi-TI7T=TTI1- I -I I � •° �rr•nrr- r-- <br />Bearing wall, Versa -Lam LVL or N.T.S. =TJ— <br />—III—�grGlulam Beam (D�-�" � I r <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />A 1Y," ROUND HOLE MAY 6" 6" <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1Y2" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAYBE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7.1Y2" ROUND KNOCKOUTS IN THE WEB MAYBE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE 1N THE WEB. THE JOIST MAY BE SET WITH THE 1Yz" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS, IT MAY. BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install tight to top flange. <br />Joist hanger <br />� \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap — <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />o depth <br />rCD <br />00 <br />Lo e <br />a.IL <br />, <br />0 Cz <br />o <br />E <br />0"co 0 <br />) <br />CD LO <br />0 <br />I -JOISTS BUCKETS <br />N.T.S. <br />SLEEVE THRU STEM—' _ <br />a. <br />SEE PLAN FOR ' °• ° . • '.; . <br />FOUNDATION INFO <br />STEM FOUNDATION <br />GRADE <br />Z__ <br />REINF. SEE PLAN <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />Y <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />e ' <br />e <br />SEE FND. PLN. <br />SIZE &REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'4" <br />CENTERED @PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />eV of . eV <br />.o <br />o a <br />�eA. .Q a <br />P <br />;r TT <br />0 <br />SEE FND. PLN. <br />SIZE & REINF. <br />0 <br />O <br />t ppP p/; <br />fPlf,€,fE <br />6j <br />R <br />O <br />r <br />4 <br />tl�d�EEI!@l44t'E��� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signatu <br />
The URL can be used to link to this page
Your browser does not support the video tag.